Literature DB >> 26910681

Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.

Edward I Chang1, Amir Ibrahim, Hong Zhang, Jun Liu, Alexander T Nguyen, Gregory P Reece, Peirong Yu.   

Abstract

BACKGROUND: The efficacy of implantable Doppler probes remains an area of considerable debate. This study aims to decipher its sensitivity and specificity for free flap monitoring.
METHODS: A retrospective review of all free flaps with an implantable Doppler probe was performed between 2000 and 2012.
RESULTS: A Cook-Swartz implantable Doppler probe was used in 439 patients (head and neck, n = 364; breast, n = 53; extremity, n = 22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity were 77.8 percent and 88.4 percent, respectively. The artery was monitored in 267 patients, compared to venous monitoring in 101 patients, and in 71 patients both the artery and vein were monitored. Arterial monitoring had significantly greater specificity than venous monitoring, (94.2 percent versus 74.0 percent; p < 0.001), but no benefit was found in monitoring both the artery and the vein. Venous monitoring was significantly associated with reoperation (OR, 3.17; 95 percent CI, 1.70 to 5.91; p = 0.0003). There were 284 flaps that had a monitoring segment in addition to the implantable Doppler probe that significantly increased overall specificity for microvascular complications (OR, 17.71; 95 percent CI, 3.39 to 92.23; p = 0.0006). The specificity (90.5 percent versus 84.8 percent) and sensitivity (80.0 percent versus 66.7 percent) were significantly higher for clinically monitored flaps. The take-back rate was 13.0 percent, with positive findings in 59.6 percent, and 5.2 percent total flap loss.
CONCLUSIONS: The use of implantable Doppler probes has high sensitivity and specificity for buried free flaps despite positive findings in less than 60 percent of take-backs. Monitoring the artery is recommended, but clinical examination remains the gold standard for flap monitoring. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.

Entities:  

Mesh:

Year:  2016        PMID: 26910681     DOI: 10.1097/01.prs.0000480016.20326.8f

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  6 in total

1.  Video Tutorial for Clinical Flap-Monitoring in Plastic Surgery.

Authors:  Daniel Schiltz; Sebastian Geis; Andreas Kehrer; Jürgen Dolderer; Lukas Prantl; Christian D Taeger
Journal:  Plast Reconstr Surg Glob Open       Date:  2017-10-24

2.  Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis.

Authors:  Melissa Berthelot; James Ashcroft; Piers Boshier; Judith Hunter; Francis Patrick Henry; Benny Lo; Guang-Zhong Yang; Daniel Leff
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-10-29

3.  Pervasive wearable device for free tissue transfer monitoring based on advanced data analysis: clinical study report.

Authors:  Melissa Berthelot; Francis Patrick Henry; Judith Hunter; Daniel Leff; Simon Wood; Navid Jallali; Elizabeth Dex; Ladislava Lysakova; Benny Lo; Guang-Zhong Yang
Journal:  J Biomed Opt       Date:  2019-06       Impact factor: 3.170

4.  Evaluation of implantable Doppler probe continuous monitoring of hepatic artery anastomosis after liver transplantation.

Authors:  Shrirang Vasant Kulkarni; Pankaj P Rao; C S Naidu; N Pathak; A K Singh
Journal:  Med J Armed Forces India       Date:  2020-06-03

5.  Deltopectoral and Pectoralis Musculocutaneous Flap Technique for Cervical Esophageal Reconstruction after Free-Jejunal-Flap Necrosis.

Authors:  Hajime Matsumine; Kazuyuki Kubo; Atsumori Hamahata; Hiroyuki Sakurai
Journal:  Plast Reconstr Surg Glob Open       Date:  2017-08-18

Review 6.  Complication of osteo reconstruction by utilizing free vascularized fibular bone graft.

Authors:  Qifeng Ou; Panfeng Wu; Zhengbing Zhou; Ding Pan; Ju-Yu Tang
Journal:  BMC Surg       Date:  2020-10-02       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.