Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis.

Gautam Shetty1,2, Shruti Khairkar3.   

Abstract

PURPOSE: To compare contact stresses between Attune® and PFC Sigma® total knee arthroplasty (TKA) implants in the presence of knee malalignment.
METHODS: Maximum contact stress after finite element analysis were compared during standing, walking, and stair climbing in 0°, 2.5° and 5°varus/valgus knee alignments.
RESULTS: The percentage increase in contact stress was highest during walking with PFC Sigma® in 5° varus (238.5%), standing with Attune® in 5° valgus (127.2%), and standing with Attune® in 2.5° valgus (107.8%).
CONCLUSION: The newer Attune® design may be associated with higher maximum contact stresses and increased risk of wear and implant failure.
© 2021 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Activities of daily living; Attune total knee replacement; Contact pressure; Finite-element analysis; Malalignment

Year:  2021        PMID: 34290486      PMCID: PMC8280525          DOI: 10.1016/j.jor.2021.07.002

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  27 in total

1.  Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis.

Authors:  A C Godest; M Beaugonin; E Haug; M Taylor; P J Gregson
Journal:  J Biomech       Date:  2002-02       Impact factor: 2.712

2.  Comparative analysis of the structural properties of the collateral ligaments of the human knee.

Authors:  William T Wilson; Angela H Deakin; Anthony P Payne; Frederic Picard; Scott C Wearing
Journal:  J Orthop Sports Phys Ther       Date:  2011-10-25       Impact factor: 4.751

3.  Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee Arthroplasty System at Implant-Cement Interface.

Authors:  Peter M Bonutti; Anton Khlopas; Morad Chughtai; Connor Cole; Chukwuweike U Gwam; Steven F Harwin; Brent Whited; Didi E Omiyi; Joshua E Drumm
Journal:  J Knee Surg       Date:  2017-06-07       Impact factor: 2.757

4.  Impact of tibial baseplate malposition on kinematics, contact forces and ligament tensions in TKA: A numerical analysis.

Authors:  Andreas Fottner; Matthias Woiczinski; Christian Schröder; Florian Schmidutz; Patrick Weber; Peter E Müller; Volkmar Jansson; Arnd Steinbrück
Journal:  J Mech Behav Biomed Mater       Date:  2019-12-07

Review 5.  Intermediate and long-term quality of life after total knee replacement: a systematic review and meta-analysis.

Authors:  Leonard Shan; Bernard Shan; Arnold Suzuki; Fred Nouh; Akshat Saxena
Journal:  J Bone Joint Surg Am       Date:  2015-01-21       Impact factor: 5.284

6.  Early tibial loosening of the cemented ATTUNE knee arthroplasty - Just a question of design?

Authors:  Sebastian Jaeger; Marvin Eissler; Martin Schwarze; Mareike Schonhoff; Jan Philippe Kretzer; Rudi G Bitsch
Journal:  Knee       Date:  2021-04-29       Impact factor: 2.199

Review 7.  Evolution of TKA design.

Authors:  Carlo Dall'Oca; M Ricci; E Vecchini; N Giannini; D Lamberti; C Tromponi; B Magnan
Journal:  Acta Biomed       Date:  2017-06-07

8.  How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up.

Authors:  Jonathan T Evans; Robert W Walker; Jonathan P Evans; Ashley W Blom; Adrian Sayers; Michael R Whitehouse
Journal:  Lancet       Date:  2019-02-14       Impact factor: 79.321

9.  A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing knee systems in patients who underwent total knee replacement with both prostheses in opposite knees.

Authors:  Brian W Carey; James Harty
Journal:  J Orthop Surg Res       Date:  2018-03-15       Impact factor: 2.359

10.  Modern cemented total knee arthroplasty design shows a higher incidence of radiolucent lines compared to its predecessor.

Authors:  Kevin Staats; Torben Wannmacher; Valerie Weihs; Ulrich Koller; Bernd Kubista; Reinhard Windhager
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-09-22       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.