Literature DB >> 28591930

Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee Arthroplasty System at Implant-Cement Interface.

Peter M Bonutti1, Anton Khlopas2, Morad Chughtai2, Connor Cole2, Chukwuweike U Gwam2, Steven F Harwin3, Brent Whited4, Didi E Omiyi5, Joshua E Drumm5.   

Abstract

Entities:  

Year:  2017        PMID: 28591930     DOI: 10.1055/s-0037-1603756

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


× No keyword cloud information.
  9 in total

1.  Clinico-Radiological and Functional Results of the Navigated Gradius (Gradually Reducing Radius) Knee Prosthesis at Short to Mid-Term Follow-Up.

Authors:  Mrinal Sharma; Bharat Dhanjani; Jibran Bashir; Anshu Kumar Anshu
Journal:  Indian J Orthop       Date:  2020-09-27       Impact factor: 1.251

2.  Analysis of the Attune tibial tray backside: A comparative retrieval study.

Authors:  A Cerquiglini; J Henckel; H Hothi; P Allen; J Lewis; A Eskelinen; J Skinner; M T Hirschmann; A J Hart
Journal:  Bone Joint Res       Date:  2019-04-02       Impact factor: 5.853

3.  Does tibial design modification improve implant stability for total knee arthroplasty? An experimental cadaver study.

Authors:  Sebastian Jaeger; Marvin Eissler; Martin Schwarze; Mareike Schonhoff; J Philippe Kretzer; Rudi G Bitsch
Journal:  Bone Joint Res       Date:  2022-04       Impact factor: 4.410

4.  Tibial Baseplate-Cement Interface Debonding in the ATTUNE Total Knee Arthroplasty System.

Authors:  Daniel Torino; Christopher Damsgaard; David J Kolessar; Daniel S Hayes; Brian Foster; Jesse Constantino; Jove Graham
Journal:  Arthroplast Today       Date:  2022-09-20

5.  India Joining the World of Hip and Knee Registries: Present Status-A Leap Forward.

Authors:  Shrinand V Vaidya; Abhinav D Jogani; Jahavir A Pachore; Richard Armstrong; Chintan S Vaidya
Journal:  Indian J Orthop       Date:  2020-09-16       Impact factor: 1.251

6.  Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis.

Authors:  Gautam Shetty; Shruti Khairkar
Journal:  J Orthop       Date:  2021-07-12

7.  A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design.

Authors:  Bart L Kaptein; Peter den Hollander; Bregje Thomassen; Martha Fiocco; Rob G H H Nelissen
Journal:  Bone Joint J       Date:  2020-09       Impact factor: 5.082

8.  Early Aseptic Failure of the Tibial Component-Cement Interface in ATTUNE® Total Knee Arthroplasty: A Report of Three Cases.

Authors:  John D Murphy; Phillip R Braunlich; William R Judson Iv; John N Harker; Patricia A Baumann
Journal:  Cureus       Date:  2021-12-21

9.  Awareness of performance on outcomes after total hip and knee arthroplasty among Dutch orthopedic surgeons: how to improve feedback from arthroplasty registries.

Authors:  Peter Van Schie; Leti Van Bodegom-Vos; Tristan M Zijdeman; Rob G H H Nelissen; Perla J Marang-Van De Mheen
Journal:  Acta Orthop       Date:  2020-10-06       Impact factor: 3.717

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.