Literature DB >> 11784545

Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis.

A C Godest1, M Beaugonin, E Haug, M Taylor, P J Gregson.   

Abstract

The stress distribution within the polyethylene insert of a total knee joint replacement is dependent on the kinematics, which in turn are dependent on the design of the articulating surfaces, the relative position of the components and the tension of the surrounding soft tissues. Implicit finite element analysis techniques have been used previously to examine the polyethylene stresses. However, these have essentially been static analyses and hence ignored the influence of the kinematics. The aim of this work was to use an explicit finite element approach to simulate both the kinematics and the internal stresses within a single analysis. A simulation of a total knee joint replacement subjected to a single gait cycle within a knee wear simulator was performed and the results were compared with experimental data.The predicted kinematics were in close agreement with the experimental data. Various solution-dependent parameters were found to have little influence on the predicted kinematics. The predicted stresses were found to be dependent on the mesh density. This study has shown that an explicit finite element approach is capable of predicting the kinematics and the stresses within a single analysis at relatively low computational cost.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11784545     DOI: 10.1016/s0021-9290(01)00179-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  62 in total

1.  The effects of implantation of tibio-femoral components in hyperextension on kinematics of TKA.

Authors:  Zhi-Wei Wang; Yu-Liang Liu; Kun-Jhih Lin; Tie-Bing Qu; Xiang Dong; Cheng-Kung Cheng; Yong Hai
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-20       Impact factor: 4.342

2.  Evaluation of the chondral modeling theory using fe-simulation and numeric shape optimization.

Authors:  Jeffrey H Plochocki; Carol V Ward; Douglas E Smith
Journal:  J Anat       Date:  2009-05       Impact factor: 2.610

3.  Patellofemoral kinematics during deep knee flexion after total knee replacement: a computational simulation.

Authors:  Chang-Hung Huang; Lin-I Hsu; Kun-Jhih Lin; Ting-Kuo Chang; Cheng-Kung Cheng; Yung-Chang Lu; Chen-Sheng Chen; Chun-Hsiung Huang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-03       Impact factor: 4.342

4.  Multibody muscle driven model of an instrumented prosthetic knee during squat and toe rise motions.

Authors:  Antonis P Stylianou; Trent M Guess; Mohammad Kia
Journal:  J Biomech Eng       Date:  2013-04       Impact factor: 2.097

5.  The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty.

Authors:  Kyoung-Tak Kang; Sae Kwang Kwon; Juhyun Son; Oh-Ryong Kwon; Jun-Sang Lee; Yong-Gon Koh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-05       Impact factor: 4.342

6.  Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners.

Authors:  Steven P Mell; Spencer Fullam; Markus A Wimmer; Hannah J Lundberg
Journal:  Proc Inst Mech Eng H       Date:  2018-04-15       Impact factor: 1.617

7.  Stress shielding in the bony chain of leg in presence of varus or valgus knee.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2014-07-17

8.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

9.  Change in collateral ligament length and tibiofemoral movement following joint line variation in TKA.

Authors:  Kun-Jhih Lin; Hung-Wen Wei; Chang-Hung Huang; Yu-Liang Liu; Wen-Chuan Chen; Colin Joseph McClean; Cheng-Kung Cheng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-30       Impact factor: 4.342

10.  Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study.

Authors:  Bernardo Innocenti; Evelyn Truyens; Luc Labey; Pius Wong; Jan Victor; Johan Bellemans
Journal:  J Orthop Surg Res       Date:  2009-07-17       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.