Literature DB >> 34272985

Blood pressure measurement in pediatric population: comparison between automated oscillometric devices and mercury sphygmomanometers-a systematic review and meta-analysis.

Keisyanne Araujo-Moura1,2, Letícia Gabrielle Souza3,4, Gabriele Luz Mello3,4, Augusto César Ferreira De Moraes3,5,4.   

Abstract

With the progressive elimination of mercury column devices for blood pressure (BP) measurement in children and adolescents, valid alternatives are needed. Oscillometric devices provide a replacement without mercury, are fully automated, and have excellent reliability among evaluators. Here, the goal was to test the accuracy of automatic blood pressure monitor devices compared to the mercury sphygmomanometer for BP measurement in children and adolescents. Electronic databases are EMBASE, MEDLINE (PubMed), SCOPUS, and Web of Science. We selected 8974 potentially eligible articles and two authors independently. We separately reviewed 370 full papers. Potentially eligible articles were selected according to the following criteria: (a) articles published in Portuguese, English, and Spanish; (b) screening of titles; (c) screening of abstracts; and (d) retrieval and screening of the full article to determine whether it met the inclusion criteria. We included 45 articles for analysis, 28 of which were selected for meta-analysis. The systolic BP measured by automatic blood pressure monitors presents 1.17 mmHg on average (95% CI 0.85; 1.48); for diastolic BP, it produced -0.08 mmHg (95% CI -0.69; 0.54) compared with a mercury sphygmomanometer. There is high heterogeneity between studies (> 90%) in the meta-analysis, partly explained by the device model, study environment, and observer training. Only articles that reported BP measurement by both methods were included.
Conclusion:  Automatic blood pressure monitors have strong measurement validity when compared with the mercury column. Thus, these can be safely used in blood pressure measurements of children and adolescents in clinical and epidemiological studies. What is Known: •The "gold standard" for indirect BP measurement is the mercury sphygmomanometer. •The accuracy of the automatic device is critical to any blood pressure measurement method. What is New: •Oscillometric or automatic devices can be a suitable alternative to auscultation for initial screening, consistent with current pediatric guidelines. •The automatic devices compared to the mercury column have a good validity of measurements, which can be used in blood pressure measurements of children and adolescents in clinical and epidemiological settings, provided that international protocols are followed.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Blood pressure; Hypertension; Pediatric population; Validity

Mesh:

Substances:

Year:  2021        PMID: 34272985     DOI: 10.1007/s00431-021-04171-3

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  5 in total

1.  Accuracy of the Dinamap Portable Monitor, model 8100: a review of the evidence for accuracy.

Authors: 
Journal:  Blood Press Monit       Date:  1997-12       Impact factor: 1.444

2.  Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175.

Authors: 
Journal:  Blood Press Monit       Date:  1996-02       Impact factor: 1.444

3.  Evaluation of blood pressure measuring devices with special reference to ambulatory systems.

Authors:  E O'Brien; K O'Malley
Journal:  J Hypertens Suppl       Date:  1990-12

4.  Oscillometric blood pressure measurements by different devices are not interchangeable.

Authors:  M A Kaufmann; H Pargger; L J Drop
Journal:  Anesth Analg       Date:  1996-02       Impact factor: 5.108

5.  Normative oscillometric blood pressure values in the first 5 years in an office setting.

Authors:  M K Park; S M Menard
Journal:  Am J Dis Child       Date:  1989-07
  5 in total
  2 in total

1.  Blood Pressure Trajectories From Childhood to Youth and Arterial Stiffness in Adulthood: A 30-Year Longitudinal Follow-Up Study.

Authors:  Chao Chu; Yue-Yuan Liao; Ming-Jun He; Qiong Ma; Wen-Ling Zheng; Yu Yan; Jia-Wen Hu; Xian-Jing Xu; Ya-Ning Fan; Rui-Hai Yang; Jian-Jun Mu
Journal:  Front Cardiovasc Med       Date:  2022-06-29

2.  The Oscillometric Pulse Wave Analysis Is Useful in Evaluating the Arterial Stiffness of Obese Children with Relevant Cardiometabolic Risks.

Authors:  Monica Simina Mihuta; Corina Paul; Andreea Borlea; Cristina Mihaela Cepeha; Iulian Puiu Velea; Ioana Mozos; Dana Stoian
Journal:  J Clin Med       Date:  2022-08-29       Impact factor: 4.964

  2 in total