Normative oscillometric blood pressure values in the first 5 years in an office setting.

M K Park1, S M Menard.   

Abstract

We measured blood pressure (BP) and heart rate in 1554 healthy infants and children aged 2 weeks to 5 years using an oscillometric device, to establish normative values in this age group. The BP cuff width was selected to be 40% to 50% of the circumference of the upper arm. Triplicate measurements of BP and heart rate were obtained in the waiting room of pediatricians' offices and well-baby clinics before the patients were examined by the physician or nurse. Three readings were possible in 87% of the infants less than 3 years of age and in all children 3 years of age and older. The average BP value (systolic/diastolic [mean]) increased rapidly from the 2- to 3-week value of 78/47 (59) mm Hg to the 1- to 5-month value of 95/60 (74) mm Hg. No subsequent increase in BP occurred until 2 years of age (96/56 [71] mm Hg) when systolic and mean pressures started to increase at an average annual rate of 2 mm Hg for systolic pressure and 1 mm Hg for mean pressure until reaching the 5-year value of 104/58 (75) mm Hg. Diastolic pressure did not increase from 1 month to 5 years of age. Heart rate decreased with increasing age from the 2- to 3-week value of 153 to the 5-year value of 97 beats per minute. There was no difference in BP and heart rate values between boys and girls or among ethnic groups over the age ranges studied. Considering the high success rate in obtaining BPs in infants and small children, it appears that BP should be determined routinely, regardless of the age of the patients, when an oscillometric device is available.

Entities:  

Mesh:

Year:  1989        PMID: 2741863     DOI: 10.1001/archpedi.1989.02150190110034

Source DB:  PubMed          Journal:  Am J Dis Child        ISSN: 0002-922X


  12 in total

Review 1.  Are pitfalls of oxcillometric blood pressure measurements preventable in children?

Authors:  Lavjay Butani; Bruce Z Morgenstern
Journal:  Pediatr Nephrol       Date:  2003-04       Impact factor: 3.714

Review 2.  Strengths and limitations of current pediatric blood pressure nomograms: a global overview with a special emphasis on regional differences in neonates and infants.

Authors:  Massimiliano Cantinotti; Raffaele Giordano; Marco Scalese; Sabrina Molinaro; Bruno Murzi; Nadia Assanta; Maura Crocetti; Marco Marotta; Sergio Ghione; Giorgio Iervasi
Journal:  Hypertens Res       Date:  2015-04-16       Impact factor: 3.872

3.  Blood pressure in non-critically ill preterm and full-term neonates.

Authors:  Bijana Pejovic; Amira Peco-Antic; Jelena Marinkovic-Eric
Journal:  Pediatr Nephrol       Date:  2006-10-20       Impact factor: 3.714

Review 4.  Hypertension in infancy: diagnosis, management and outcome.

Authors:  Janis M Dionne; Carolyn L Abitbol; Joseph T Flynn
Journal:  Pediatr Nephrol       Date:  2011-01-22       Impact factor: 3.714

5.  Blood pressure in prospective population based cohort of newborn and infant twins.

Authors:  R S Levine; C H Hennekens; M J Jesse
Journal:  BMJ       Date:  1994-01-29

6.  Plasma renin activity in haemolytic uraemic syndrome.

Authors:  W Proesmans; A VanCauter; L Thijs; P Lijnen
Journal:  Pediatr Nephrol       Date:  1994-08       Impact factor: 3.714

7.  Predictive score for clinical complications during intra-hospital transports of infants treated in a neonatal unit.

Authors:  Anna Luiza Pires Vieira; Amélia Miyashiro Nunes dos Santos; Mariana Kobayashi Okuyama; Milton Harumi Miyoshi; Maria Fernanda Branco de Almeida; Ruth Guinsburg
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

8.  Blood pressure centiles for Great Britain.

Authors:  Lisa V Jackson; Nandu K S Thalange; Tim J Cole
Journal:  Arch Dis Child       Date:  2006-08-11       Impact factor: 3.791

9.  Oscillometric blood pressure reference values of African full-term neonates in their first days postpartum.

Authors:  W E Sadoh; S E Ibhanesebhor
Journal:  Cardiovasc J Afr       Date:  2009 Nov-Dec       Impact factor: 1.167

Review 10.  Blood pressure measurement in pediatric population: comparison between automated oscillometric devices and mercury sphygmomanometers-a systematic review and meta-analysis.

Authors:  Keisyanne Araujo-Moura; Letícia Gabrielle Souza; Gabriele Luz Mello; Augusto César Ferreira De Moraes
Journal:  Eur J Pediatr       Date:  2021-07-17       Impact factor: 3.183

View more