Julien Montreuil1,2, Joseph Saleh3, Thierry Cresson1, Jacques A De Guise1, Frédéric Lavoie4. 1. Laboratoire de recherche en Imagerie et Orthopédie de l'ETS, Montréal, Québec, Canada. 2. McGill Division of Orthopaedic Surgery, Montreal General Hospital, Montréal, Québec, Canada. 3. Faculté de Médecine, Université de Sherbrooke, Sherbrooke, Québec, Canada. 4. Service de chirurgie orthopédique, Centre Hospitalier de l'Université de Montréal, Montréal, Québec, Canada.
Abstract
BACKGROUND: Nonanatomic graft placement is a frequent cause of anterior cruciate ligament reconstruction (ACLR) failure, and it can be attributed to either tibial or femoral tunnel malposition. To describe tibial tunnel placement in ACLR, we used EOS, a low-dose biplanar stereoradiographic imaging modality, to create a comprehensive grid that combines anteroposterior (AP) and mediolateral (ML) coordinates. PURPOSE: To (1) validate the automated grid generated from EOS imaging and (2) compare the results with optimal tibial tunnel placement. STUDY DESIGN: Descriptive laboratory study. METHODS: Using EOS, 3-dimensional models were created of the knees of 37 patients who had undergone ACLR. From the most medial, lateral, anterior, and posterior points on the tibial plateau of the EOS 3-dimensional model for each patient, an automated and personalized grid was generated from 2 independent observers' series of reconstructions. To validate this grid, each observer also manually measured the ML and AP distances, the medial proximal tibial angle (MPTA), and the tibial slope for each patient. The ideal tibial tunnel placement, as described in the literature, was compared with the actual tibial tunnel grid coordinates of each patient. RESULTS: The automated grid metrics for observer 1 gave a mean (95% CI) AP depth of 54.7 mm (53.4-55.9), ML width of 75.0 mm (73.3-76.6), MPTA of 84.9° (83.7-86.0), and slope of 7.2° (5.4-9.0). The differences with corresponding manual measurements were means (95% CIs) of 2.4 mm (1.4-3.4 mm), 0.5 mm (-1.3 to 2.2 mm), 1.2° (-0.4° to 2.9°), and -0.4° (-2.1° to 1.2°), respectively. The correlation between automated and manual measurements was r = 0.78 for the AP depth, r = 0.68 for the ML width, r = 0.18 for the MPTA, and r = 0.44 for the slope. The center of the actual tibial aperture on the plateau was a mean of 5.5 mm (95% CI, 4.8-6.1 mm) away from the referenced anatomic position, with a tendency toward more medial placement. CONCLUSION: The automated grid created using biplanar stereoradiographic imaging provided a novel, precise, and reproducible description of the tibial tunnel placement in ACLR. CLINICAL RELEVANCE: This technique can be used during preoperative planning, intraoperative guidance, and postoperative evaluation of tibial tunnel placement in ACLR.
BACKGROUND: Nonanatomic graft placement is a frequent cause of anterior cruciate ligament reconstruction (ACLR) failure, and it can be attributed to either tibial or femoral tunnel malposition. To describe tibial tunnel placement in ACLR, we used EOS, a low-dose biplanar stereoradiographic imaging modality, to create a comprehensive grid that combines anteroposterior (AP) and mediolateral (ML) coordinates. PURPOSE: To (1) validate the automated grid generated from EOS imaging and (2) compare the results with optimal tibial tunnel placement. STUDY DESIGN: Descriptive laboratory study. METHODS: Using EOS, 3-dimensional models were created of the knees of 37 patients who had undergone ACLR. From the most medial, lateral, anterior, and posterior points on the tibial plateau of the EOS 3-dimensional model for each patient, an automated and personalized grid was generated from 2 independent observers' series of reconstructions. To validate this grid, each observer also manually measured the ML and AP distances, the medial proximal tibial angle (MPTA), and the tibial slope for each patient. The ideal tibial tunnel placement, as described in the literature, was compared with the actual tibial tunnel grid coordinates of each patient. RESULTS: The automated grid metrics for observer 1 gave a mean (95% CI) AP depth of 54.7 mm (53.4-55.9), ML width of 75.0 mm (73.3-76.6), MPTA of 84.9° (83.7-86.0), and slope of 7.2° (5.4-9.0). The differences with corresponding manual measurements were means (95% CIs) of 2.4 mm (1.4-3.4 mm), 0.5 mm (-1.3 to 2.2 mm), 1.2° (-0.4° to 2.9°), and -0.4° (-2.1° to 1.2°), respectively. The correlation between automated and manual measurements was r = 0.78 for the AP depth, r = 0.68 for the ML width, r = 0.18 for the MPTA, and r = 0.44 for the slope. The center of the actual tibial aperture on the plateau was a mean of 5.5 mm (95% CI, 4.8-6.1 mm) away from the referenced anatomic position, with a tendency toward more medial placement. CONCLUSION: The automated grid created using biplanar stereoradiographic imaging provided a novel, precise, and reproducible description of the tibial tunnel placement in ACLR. CLINICAL RELEVANCE: This technique can be used during preoperative planning, intraoperative guidance, and postoperative evaluation of tibial tunnel placement in ACLR.
The anterior cruciate ligament (ACL) is an important stabilizer of the knee that is
frequently injured. Globally, 400,000 ACL reconstructions (ACLRs) are performed each year.
Tibial and femoral tunnel malposition are a common cause of ACLR failure.
Although there are an abundance of studies describing the ideal femoral tunnel
placement, there is much less of a focus in the literature on defining the optimal
tibial tunnel positioning.
Multiple reconstruction techniques target an anatomic placement of the tibial and
femoral tunnels.
Tibial tunnels placed too far anteriorly may lead to increased graft obliquity
and subsequent impingement, whereas grafts placed too far posteriorly may lead to
increased anterior translational laxity.
Several studies have used 3-dimensional (3D) computed tomography (CT) scans to
examine anatomic landmarks and to guide intraoperative tibial tunnel placement.
Other studies have focused on image-guided techniques, such as radiographs and CT
scans, to evaluate tunnel placement on the tibial and femoral surfaces.
As the tibial plateau can be viewed as a 2-dimensional surface in the axial
plane, a grid could be used to describe the desired tunnel placement with 2 coordinates.
For the anteroposterior (AP) direction, Amis and Jakob
were the original authors to popularize the placement as a percentage along a
line of reference extending from the anterior portion of the proximal tibia to the most
posterior portion, while being parallel to the tibial plateau.
Other methods have considered the tibial slope and used the tibial articular
surface to describe a given position with a percentage along the AP depth.
For the mediolateral (ML) placement on an AP radiograph, few studies have
described the optimal location of tunnel placement.EOS is a biplanar stereoradiographic imaging modality (Figure 1) (EOS imaging, Paris, France). By
capturing simultaneous radiographic images in AP and lateral views, the EOS system is
able to generate 3D surface reconstructions. Capturing the images in an upright,
load-bearing position allows EOS to generate a true 1:1 scaled image with respect to
length. In addition, EOS technology generates these images at a 10 times lower radiation
level when compared with conventional films.
A previous study by our group demonstrated that, compared with 3D CT scan, EOS 3D
reconstruction is a precise and efficient technique with good inter- and intraobserver reproducibility.
Figure 1.
Three-dimensional models issued from the EOS imaging system. Image used with
permission from EOS imaging.
Three-dimensional models issued from the EOS imaging system. Image used with
permission from EOS imaging.In this study, we used the EOS imaging system to describe the tibial tunnel aperture
location in ACLR using an automated grid reference of the tibial plateau. We expected
the automated grid to correspond to manual measurements for direction (AP and ML) and
angulation (medial proximal tibial angle [MPTA] and tibial slope in the sagittal plane).
We also expected the actual postoperative tibial tunnel aperture position to be
within proximity of the ideal tunnel location, described in the literature at 40% in the
AP axis and 51% in the ML axis from the medial origin.
Methods
Study Patients
After receiving ethics committee approval, we selected 37 study patients from the
cohort “Prospective Collection of Clinical and Radiological Data in Knee
Patients” at our institution in Montréal, Canada. The sample size included 25
men and 12 women with a mean ± SD age of 31.8 ± 3.0 years; there were 21 right
knees and 16 left knees. All patients had undergone ACLR by the same surgeon
(F.L.), between 2008 and 2011, using a single-bundle technique using a hamstring
autograft, constant graft sizing method, and a tibial guide set between 50° and
60° according to the patient’s anatomy. The medial half of the tibial eminence
and the anterior horn of the lateral meniscus were important landmarks used. All
patients were judged as having successful reconstructions and underwent
postoperative EOS imaging of their lower limbs 6 months after surgery.
3D Models Issued From EOS Images
The 3D models were generated using a pair of EOS images with orthogonal oblique
views, (Figure 2); this
method facilitated the identification of anatomic landmarks for each patient
because it limited the superposition of structures. The images were processed
using IdefX software (Laboratoire de recherche en Imagerie et Orthopédie de
l’ETS), and 3D reconstructions were generated for both the tibia and the femur
of each knee in the study. The process of 3D reconstruction consisted of
adjusting, for each bone, the position and the shape of a generic 3D model to
the stereoradiographic images of each study patient. A moving least squares
optimization technique allowed us to achieve fast detail-preserving deformation
to find the best alignment between the 2 projected silhouettes of the 3D
template model and the boundaries of the patient’s bones. The reconstructions
benefited from an integrated reference system (Figure 3). Tibial tunnels were also
identified on postoperative 3D reconstructions with the “conical shape” tool in
IdefX. With this tool, the tibial aperture is defined as a circle around a
central axis. Each 3D model was reconstructed separately by 2 independent
observers (observer 1, J.M.; observer 2, J.S.) in order to test interobserver
reliability.
Figure 2.
Example of a 3-dimensional model reconstructed using the EOS system.
Figure 3.
Generic reference system with 3-dimensional reconstructions of the
proximal tibia before tibial tunnel segmentation. (A) Sagittal view. (B)
Axial view of tibia. Ant, anterior; Lat, lateral; Sup, superior.
Example of a 3-dimensional model reconstructed using the EOS system.Generic reference system with 3-dimensional reconstructions of the
proximal tibia before tibial tunnel segmentation. (A) Sagittal view. (B)
Axial view of tibia. Ant, anterior; Lat, lateral; Sup, superior.
Tibial Grid Conception
A rectangular grid was developed for each patient to describe the tunnel
placement on the tibial plateau. Each of the 3D models issued from EOS had
different regions mapped, which were used to automatically identify the most
anterior, posterior, medial, and lateral points (Figure 4). A sagittal plane bisecting the
plateau was defined and used to calculate the most medial and lateral points.
The same technique with a coronal plane was used to identify the most anterior
and posterior points. We defined the automated grid using 2 lines: 1 that
extended from the medial and lateral points and 1, perpendicular, that extended
from the anterior point to the posterior point. This grid then allowed us to
describe any point on the tibial plateau as a percentage of the AP axis along
with a percentage of the ML axis (Figure 5).
Figure 4.
Automated region segmentation (red) from an EOS 3-dimensional model with
medial (left image), anterior (middle), and posterior (right)
points.
Figure 5.
Automated grid delimitation.
Automated region segmentation (red) from an EOS 3-dimensional model with
medial (left image), anterior (middle), and posterior (right)
points.Automated grid delimitation.
Grid Validation
To validate our automated technique, the 2 observers manually measured 4
parameters on the 3D models: the AP depth, ML width, MPTA, and sagittal tibial
slope. In order to obtain the manual measurements, the appropriate participant
3D reconstruction mesh was rotated to obtain optimal views. First, the AP depth
and the ML width of the tibial plateau were measured on an axial view (Figure 6). Second, the
tibial slope was measured on a sagittal view. Third, the MPTA was measured on
the coronal view (Figure
7). The values obtained by each observer were compared with the
automated values that were generated.
Figure 6.
For automated grid validation, manual measurements of the anteroposterior
depth and mediolateral width were obtained from 3-dimensional
reconstructions for grid validation. Ant, anterior; Lat, lateral; Med,
medial; Post, posterior.
Figure 7.
Manual measurements of (A) tibial slope and (B) medial proximal tibial
angle for grid validation.
For automated grid validation, manual measurements of the anteroposterior
depth and mediolateral width were obtained from 3-dimensional
reconstructions for grid validation. Ant, anterior; Lat, lateral; Med,
medial; Post, posterior.Manual measurements of (A) tibial slope and (B) medial proximal tibial
angle for grid validation.
Anatomic Tunnel Placement
Using our 2-dimensional grid referential, we were able to define any point along
the tibial plateau. The AP and ML coordinates were converted to percentages from
the most anterior and lateral points, respectively. As described in the
literature, the anatomic location of the ACL insertion on the tibial plateau was
placed as 40% in the AP axis and 51% in the ML axis.
With this anatomic position, we were able to compare the actual tibial
tunnels in our models to the ideal operating point. For this project, the
central axis of a best-fit circle in the tibial aperture was used. We calculated
the Euclidean distance, which is a linear distance connecting the ideal point to
the actual tibial tunnel aperture, for each patient.
Statistical Analysis
A minimum sample size of 25 patients for this study was calculated with an alpha
of 5%, a power of 90%, an acceptable intraclass correlation coefficient (ICC) of
0.70, and an expected ICC of 0.90.
Based on previous studies, the clinically important differences were set
for length (3 mm) and angulation (4°).
Estimates for ICCs and their 95% CIs were calculated using GraphPad Prism
Version 8. The same software was used to perform paired Student
t tests and Pearson correlation for the intertest
correlation and the interobserver reliability study for all parameters.
Reliability was determined as follows: ICC <0.5 indicated poor reliability,
0.5 to 0.74 indicated moderate reliability, 0.75 to 0.9 indicated good
reliability, and >0.90 indicated excellent reliability.
Results
The results of the EOS automated and manual measurements for the AP depth, ML width,
MPTA, and sagittal tibial slope are shown in Table 1 and Figure 8. The grid metrics obtained from the
automated method for observer 1 indicated a mean AP depth of 54.7 mm, ML width of
75.0 mm, tibial slope of 7.2°, and MPTA of 84.9°. The corresponding metrics measured
manually were 52.3 mm, 75.4 mm, 6.7°, and 86.1°, respectively. The automated
measures for observer 2 were 53.9 mm, 73.7 mm, 7.8°, and 84.9°, respectively. The
corresponding manual metrics for observer 2 were 52.1 mm, 72.1 mm, 6.8°, and 86.5°,
respectively (Figure 8).
Differences between measuring modalities for all four tibial grid parameters are
shown in Table 2.
Table 1
Tibial Grid Parameters From the 3-Dimensional Reconstructions of the Study
Knees (N = 37)
Within clinically important difference for that variable.
Thresholds are stated in the Methods section.
Statistically significant (P < .05).
Tibial Grid Parameters From the 3-Dimensional Reconstructions of the Study
Knees (N = 37)AP, anteroposterior; ML, mediolateral; MPTA, medial proximal
tibial angle.Validation of EOS automated grid parameters. AP, anteroposterior; ML,
mediolateral.Intertest and Interobserver Analysis of Tibial Grid ParametersSubscript numbers indicate observer number. AP,
anteroposterior; ML, mediolateral; MPTA, medial proximal tibial
angle.Within clinically important difference for that variable.
Thresholds are stated in the Methods section.Statistically significant (P < .05).Compared with the ideal anatomic position of the ACL, which is 40% in AP depth and
51% in ML width, the 3D reconstructions of observer 1 showed a mean tunnel position
of 40.2% of AP depth and 54.3% of ML width (Table 3). The same metrics for the
corresponding series of observer 2 were 41.4% for AP depth and 55.0% for ML width.
For both observers, the mean Euclidean distance to the ideal position was 5.5 mm
(Figure 9).
Table 3
Tibial Tunnel Aperture Position
AP Ratio, %
ML Ratio, %
▵ to Anatomic Position, mm
Mean
95% CI
Mean
95% CI
Mean
95% CI
Observer 1
40.2
37.9-42.6
54.3
53.2-55.4
5.5
4.8-6.1
Observer 2
41.4
39.4-43.3
55.0
54.2-55.9
5.5
4.8-6.1
ICC
0.57 (P = .0002b)
0.52 (P = .009b)
0.49 (P = .002b)
Ideal anteroposterior (AP) ratio = 40%, ideal mediolateral (ML)
ratio = 51%. ICC, intraclass correlation coefficient.
Statistically significant (P < .05).
Figure 9.
Actual tibial tunnel position and coordinates from observers 1 and 2.
Tibial Tunnel Aperture PositionIdeal anteroposterior (AP) ratio = 40%, ideal mediolateral (ML)
ratio = 51%. ICC, intraclass correlation coefficient.Statistically significant (P < .05).Actual tibial tunnel position and coordinates from observers 1 and 2.
Discussion
The purpose of this study was to describe the tibial tunnel aperture in ACLR using a
novel grid reference from a 3D reconstruction of the proximal tibia, which was
issued from an EOS biplanar imaging system. This grid, created using orthogonal
lines through the most anterior, posterior, medial, and lateral positions of the
tibial plateau, allows for the description of any desired point on the plateau. In
order to validate this grid, the AP depth, ML width, MPTA, and sagittal slope were
calculated both automatically and manually by 2 independent observers’ series of 3D
reconstructions. The actual tibial apertures, identified by each observer during the
reconstructions, were compared with the anatomic placement as described in the
literature. Previous studies have developed and tested coordinate systems of the
tibia using CT scans in order to automatically produce 3D reconstructions.
Outlines using cross-sectional images created an ellipse on the tibial
plateau with axes in both the AP and the ML directions.
To the best of our knowledge, there have been no studies that have evaluated
an automatic grid reference using the EOS imaging system. As previously stated, this
biplanar stereoradiographic system has the ability to create 3D reconstructions in a
true 1:1 scale for sizes, lengths, and angles while also emitting significantly less radiation.The 4 parameters chosen to validate our grid referential allowed us to conduct
intertest analysis and interobserver reproducibility studies and interpret the
results using equivalence tests. Dimensions and alignment of the tibial plateau are
known from numerous previously conducted studies and helped establish equivalence
thresholds. Cadaveric studies have shown that the mean dimensions were 50.5 ± 6.2 mm
and 77.7 ± 5.9 mm for AP depth and ML width of the tibial plateau, respectively.
Imaging studies using CT scans have shown similar results, with 54.4 ± 5.2 mm
and 74.4 ± 5.5 mm for AP depth and ML width, respectively.
With respect to the tibial slope, it has been described to be 7° to 10°, with
variability of 4.8° using planar imaging.
Finally, for the MPTA, 87.2° ± 2.1° is the value described in the literature.In our study, when comparing both the manual and automated methods for the different
parameters, the ML width and both coronal (MPTA) and sagittal (slope) angulation all
showed no statistical difference while respecting our pre-established equivalence
threshold. These results underline the overall validity of our automated method.
Despite displaying a good correlation, the automated AP depth showed a significant
difference compared with manual measurements and slightly surpassed the equivalence
threshold of 3 mm. Because of the limited programmed handles to adjust the generic
models, we believe that the posterior aspect of the plateau is the source of the
discrepancies, especially at the posterolateral corner of the plateau. In fact, some
reconstructions displayed a nonanatomic prominence. In order to limit outliers, we
excluded this posterolateral surface when searching for the most posterior point. A
suboptimal definition of the posterior point could therefore explain the
variabilities seen on the AP depth and sagittal angulation measures (slope). For the
MPTA, although there was only a 1.2° mean difference between both the automated and
manual measurements, the correlation between both modalities was the weakest. We
believe this can most likely be attributed to the imprecision in the manual
measurements compared with the automated technique, which used fixed points in
defining the MPTA. This observation is supported by an overall interobserver
reproducibility that was superior in the automated method compared with manual
measures.In fact, by having both manual and automated measures for both observers, we were
able to compare the interobserver reproducibility of the automated technique to that
of the manual technique. With respect to the AP depth, both the automated and the
manual measures were equivalent, displaying good correlation (r =
0.81; P < .0001). Most importantly, to highlight the advantage
of the automated process, for the ML width and MPTA, the automated technique
displayed greater reproducibility than did the manual technique. The automated
measures displayed good correlation for both ML width and MPTA (r =
0.87, P < .0001; and r = 0.70,
P < .0001, respectively), whereas the manual technique
displayed moderate correlation for both ML width and MPTA (r =
0.53, P = .0003; and r = 0.54, P
= 0.003, respectively).The final objective of this study was to describe the mean Euclidean distance between
the optimal tunnel position and the actual apertures identified on our models (Figure 9). We used percentages
along the AP depth and ML width of the tibial plateau as coordinates. With respect
to the cited anatomic points of 40% in the AP direction and 51% in the ML direction,
the mean Euclidean distance was measured with both observers obtaining 5.5 mm (95%
CI, 4.8-6.1),
erring more medially. These results are comparable with techniques using
magnetic resonance imaging for tibial tunnel positioning analysis.
This precision on a surgical level is also satisfying when considering the
large anatomic tibial footprints described in the literature.
Edwards et al.
described the length of the footprint to be 18 ± 2 mm and the width 9 ± 2 mm.
Figure 9 illustrates the
tendency toward a more anteromedial placement of the tibial tunnel. It places the
posterolateral aspect of the tibial aperture overlying the ideal position.
Therefore, because the graft sits in the posterolateral aspect of the tibial
aperture, this may become the ideal biomechanical position.
This eccentric tunnel aperture placement was noted by Clancy et al.
Biomechanical and clinical effects of such small differences have yet to be
shown. Overall, this automated grid technique adequately described both the AP depth
and ML width coordinates of drilled tibial tunnels in an ACLR.Combining this tibial grid with the femoral reference system described by our group
could offer numerous possibilities. Further studies could evaluate the effect of
preoperative planning and the precision of individualized surgical guides. Another
avenue could be to overlay the 3D reconstructions and ideal targets on the actual
arthroscopy screen. This tool could also be used for postoperative feedback in ACLR.
We could compare tunnel placement between surgeons or different placement
techniques. Finally, we aim to analyze clinical outcomes depending on tunnel
position.Although promising results were obtained using this novel grid reference, there are
limitations to our study. As each model was 3D reconstructed semimanually by each
observer, human operator imprecisions in the reconstructions may have affected the
results. Indeed, having completely automated reconstructions would likely improve
the accuracy and reliability of the reconstructions while speeding up an already
efficient process. As discussed earlier, given the limited programmed handles to
adjust the generic models, the most posterior point on the automated models was
restricted to the posteromedial region because of posterolateral inaccuracies seen
in the 3D reconstructions, which were excluded. A suboptimal definition of the
posterior point could explain the variabilities seen on the AP depth and sagittal
angulation (slope) measures. We suggest further refining of this posterolateral
region on the 3D models in future studies.Another improvement could be to integrate an oval shape as the intra-articular
aperture. This would respect the actual aperture shape, its effect on graft
placement, and considerations toward eccentric positioning. Moreover, our database
consisted of patients who underwent ACLR by a single surgeon using a single
technique. While this represents a limitation to our study with regard to its
external validity, it allowed us to limit confounding factors and evaluate its
reliability. We also want to emphasize the fact that the ideal location of tunnel
drilling in ACLR has yet to be found through clinical and biomechanical studies. We
are well aware that further studies could support different placement than the one
shared in this paper.Finally, the accessibility of such a system is limited, restricting our knowledge
about reproducibility among different centers. This reproducibility will need to be
established before our technique is scaled. Sharing data among institutions using
EOS will augment the sample size while obtaining results from other surgeons with
different surgical techniques. This should improve the precision and
generalizability of our method. Although it was not the aim of the present
radiologic descriptive study, evaluating the clinical effect of the tunnel’s
position in ACLR remains a priority of our group.
Conclusion
This novel automated coordinate system using biplanar stereoradiographic
low-irradiation imaging showed a precision comparable with that of standard manual
measurements in ACLR tibial tunnel placement. Our results suggest that the automated
grid issued from EOS knee reconstruction shows good accuracy and reproducibility.
Although the results of this preliminary study are promising, we strive to improve
our method by refining further parameters to evaluate and revalidate the present
technique.
Authors: Sebastian Kopf; Volker Musahl; Scott Tashman; Michal Szczodry; Wei Shen; Freddie H Fu Journal: Knee Surg Sports Traumatol Arthrosc Date: 2009-01-13 Impact factor: 4.342
Authors: Andrew S Bernhardson; Zachary S Aman; Grant J Dornan; Bryson R Kemler; Hunter W Storaci; Alex W Brady; Gilberto Y Nakama; Robert F LaPrade Journal: Am J Sports Med Date: 2019-01-14 Impact factor: 6.202
Authors: Christopher Pedneault; Carl Laverdière; Adam Hart; Mathieu Boily; Mark Burman; Paul A Martineau Journal: Am J Sports Med Date: 2019-09-12 Impact factor: 6.202