| Literature DB >> 34244266 |
Peter Magnusson1,2,3, Gustav Mattsson2, Marita Wallhagen4, Jan Karlsson5.
Abstract
OBJECTIVES: Decisions regarding implantable cardioverter defibrillators (ICDs) must consider information about presumed health-related quality of life (HRQL). The purpose of the study was to assess HRQL in patients with ICD and compare it to a Swedish age-matched and sex-matched population.Entities:
Keywords: adult cardiology; cardiology; heart failure; pacing & electrophysiology
Mesh:
Year: 2021 PMID: 34244266 PMCID: PMC8273444 DOI: 10.1136/bmjopen-2020-047053
Source DB: PubMed Journal: BMJ Open ISSN: 2044-6055 Impact factor: 2.692
Figure 1Flowchart. ICD, implantable cardioverter defibrillator.
Characteristics at ICD implant of 223 patients who completed the SF-36
| Patients | 223 |
| Mean age at implant | 64.1±10.9 years |
| Mean age at SF-36 | 71.1±9.7 years |
| Females | 40 (17.9%) |
| Device type | |
| ICD-VR | 36 (16.1%) |
| ICD-DR | 112 (50.2%) |
| CRT-D | 75 (33.6%) |
| Hypertension | 104 (46.6%) |
| Diabetes mellitus | 47 (21.1%) |
| Renal failure* | 27 (12.1%) |
| Atrial fibrillation | 62 (27.8%) |
| Beta-blockers | 201 (90.1%) |
| ACE-i/ARB | 193 (86.5%) |
| MRA | 104 (46.6%) |
Data presented as frequencies (percentage in parenthesis).
*Defined as S-creatinine≥130 μmol/L.
ACE-i, ACE inhibitor; ARB, angiotensin receptor blockers; CRT-D, cardiac resynchronisation therapy defibrillator; ICD-DR, dual lead implantable cardioverter defibrillator; ICD-VR, single lead implantable cardioverter defibrillator; MRA, mineralcorticoid receptor antagonist; SF-36, short form 36.
Figure 2Bar chart: Health-related quality of life among patients with ICD compared with age-matched and sex-matched norms. BP, bodily pain; GH, general health; ICD, implantable cardioverter defibrillator; MH, mental health; PF, physical functioning; RE, role-emotional; RP, role-physical; SF, social functioning; VT, vitality.
SF-36 score in patients with ICDs compared with general Swedish population norms
| SF-36 domains | Cohort mean | SD | 95% CI | Effect size | Norm mean | SD | 95% CI | P value |
| Physical functioning | 65.1 | 28.1 | 61.4 to 68.8 | 0.38 | 75.5 | 26.0 | 71.5 to 79.6 |
|
| Role physical | 56.9 | 44.1 | 50.9 to 62.8 | 0.23 | 66.7 | 40.4 | 60.2 to 73.2 |
|
| Bodily pain | 71.9 | 29.9 | 67.9 to 75.8 | 71.0 | 27.2 | 66.9 to 75.1 | 0.6395 | |
| General health | 56.2 | 21.7 | 53.3 to 59.1 | 0.41 | 65.9 | 25.3 | 61.9 to 70.0 |
|
| Vitality | 58.0 | 24.8 | 54.7 to 61.3 | 0.39 | 68.1 | 27.2 | 63.7 to 72.4 |
|
| Social functioning | 80.1 | 24.4 | 76.8 to 83.3 | 0.25 | 85.9 | 22.9 | 82.4 to 89.4 |
|
| Role emotional | 72.2 | 39.9 | 66.9 to 77.6 | 76.7 | 35.7 | 71.1 to 82.4 | 0.3730 | |
| Mental health | 76.2 | 19.4 | 73.6 to 78.8 | 0.38 | 83.8 | 20.9 | 80.5 to 87.2 |
|
| Physical component summary | 40.7 | 12.3 | 39.0 to 42.4 | 0.31 | 44.4 | 11.6 | 42.4 to 46.4 |
|
| Mental component summary | 48.6 | 10.8 | 47.2 to 50.1 | 0.31 | 51.9 | 10.5 | 50.1 to 53.8 |
|
Bold P values refer to significant values (<0.05).
ICD, implantable cardioverter defibrillator; SF-36, short form 36.
Short form 36 (SF-36) score in patients with implantable cardioverter defibrillators stratified by age
| SF-36 domains | 32–59 (n=25) | 60–69 (n=72) | 70–79 (n=76) | 80+ (n=50) | P value* |
| Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | ||
| Physical functioning | 79.4 (25.4) | 71.9 (26.3) | 62.7 (29.0) | 51.4 (24.4) |
|
| Role-physical | 80.0 (36.8) | 60.0 (44.9) | 56.0 (43.9) | 40.9 (41.6) |
|
| Bodily pain | 80.8 (29.3) | 74.4 (30.9) | 71.5 (28.8) | 64.2 (29.2) | 0.0780 |
| General health | 57.5 (21.2) | 56.0 (22.6) | 56.2 (21.9) | 55.7 (20.7) | 0.9827 |
| Vitality | 64.6 (20.4) | 59.7 (27.5) | 56.5 (23.8) | 54.3 (23.9) | 0.2363 |
| Social functioning | 84.0 (22.7) | 79.3 (27.9) | 80.3 (22.1) | 78.8 (23.5) | 0.8341 |
| Role-emotional | 82.7 (33.5) | 75.6 (38.6) | 73.6 (39.1) | 59.7 (44.0) | 0.0773 |
| Mental health | 77.8 (18.2) | 77.2 (21.2) | 74.4 (18.8) | 76.8 (18.3) | 0.6190 |
| Physical component summary | 46.6 (11.1) | 42.2 (12.7) | 40.0 (11.9) | 36.0 (11.4) |
|
| Mental component summary | 48.6 (10.3) | 48.3 (12.0) | 48.6 (10.4) | 49.3 (10.1) | 0.9859 |
Bold P values refer to significant values (<0.05).
Subgroup analyses of patients with ICD
| SF-36 domains | Atrial fibrillation* | Complications | Appropriate therapy | Inappropriate shock | ||||
| P value | ES | P value | ES | P value | ES | P value | ES | |
| Physical functioning |
| 0.41 | 0.500 | 0.947 | 0.592 | |||
| Role physical | 0.128 | 0.210 | 0.897 | 0.428 | ||||
| Bodily pain |
| 0.27 | 0.167 | 0.544 | 0.381 | |||
| General health | 0.606 | 0.190 | 0.863 | 0.921 | ||||
| Vitality |
| 0.31 | 0.321 | 0.919 | 0.765 | |||
| Social functioning | 0.669 | 0.910 | 0.943 | 0.944 | ||||
| Role emotional | 0.313 | 0.972 | 0.796 | 0.955 | ||||
| Mental health | 0.912 | 0.769 | 0.747 | 0.972 | ||||
| Physical component summary |
| 0.38 | 0.107 | 0.696 | 0.464 | |||
| Mental Component Summary | 0.923 | 0.902 | 0.772 | 0.375 | ||||
Bold P values refer to significant values (<0.05).
*Effect sizes were lower when atrial fibrillation was present.
ES, effect size; ICD, implantable cardioverter defibrillator; SF-36, short form 36.