Literature DB >> 20837894

Long-term benefit of primary prevention with an implantable cardioverter-defibrillator: an extended 8-year follow-up study of the Multicenter Automatic Defibrillator Implantation Trial II.

Ilan Goldenberg1, John Gillespie, Arthur J Moss, W Jackson Hall, Helmut Klein, Scott McNitt, Mary W Brown, Iwona Cygankiewicz, Wojciech Zareba.   

Abstract

BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II) showed a significant 31 reduction in the risk of death with primary implantable cardioverter-defibrillator (ICD) therapy during a median follow-up of 1.5 years. However, currently there are no data on the long-term efficacy of primary defibrillator therapy. METHODS AND
RESULTS: MADIT-II enrolled 1232 patients with ischemic left ventricular dysfunction who were randomized to ICD and non-ICD medical therapy and were followed up through November 2001. For the present long-term study, we acquired posttrial mortality data through March 2009 for all study participants (median follow-up, 7.6 years). Multivariate Cox proportional hazards regression modeling was performed to calculate the hazard ratio for ICD versus non-ICD therapy during long-term follow-up. At 8 years of follow-up, the cumulative probability of all-cause mortality was 49 among patients treated with an ICD compared with 62 among non-ICD patients (P<0.001). Multivariate analysis demonstrated that ICD therapy was associated with a significant long-term survival benefit (hazard ratio for 0- through 8-year mortality=0.66 [95 confidence interval, 0.56 to 0.78]; P<0.001). Treatment with an ICD was shown to be associated with a significant reduction in the risk of death during the early phase of the extended follow-up period (0 through 4 years: hazard ratio=0.61 [95 confidence interval, 0.50 to 0.76]; P<0.001) and with continued life-saving benefit during the late phase of follow-up (5 through 8 years: hazard ratio=0.74 [95 confidence interval, 0.57 to 0.96]; P=0.02).
CONCLUSIONS: Our findings demonstrate a sustained 8-year survival benefit with primary ICD therapy in the MADIT-II population.

Entities:  

Mesh:

Year:  2010        PMID: 20837894     DOI: 10.1161/CIRCULATIONAHA.110.940148

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  45 in total

1.  Device therapy: Who may and who may not benefit from an ICD?

Authors:  Arnold Pinter; Paul Dorian
Journal:  Nat Rev Cardiol       Date:  2010-11-16       Impact factor: 32.419

2.  Survival benefit of the primary prevention implantable cardioverter-defibrillator among older patients: does age matter? An analysis of pooled data from 5 clinical trials.

Authors:  Paul L Hess; Sana M Al-Khatib; Joo Y Han; Rex Edwards; Gust H Bardy; J Thomas Bigger; Alfred Buxton; Riccardo Cappato; Paul Dorian; Al Hallstrom; Alan H Kadish; Peter J Kudenchuk; Kerry L Lee; Daniel B Mark; Arthur J Moss; Richard Steinman; Lurdes Y T Inoue; Gillian Sanders
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2015-02-10

Review 3.  [ICD therapy in the primary prevention of sudden cardiac death: Risk stratification and patient selection].

Authors:  J Neuzner; R Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-06-04

Review 4.  The subcutaneous ICD-current evidence and challenges.

Authors:  Kiran Haresh Kumar Patel; Pier D Lambiase
Journal:  Cardiovasc Diagn Ther       Date:  2014-12

5.  Shock or no shock - a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?

Authors:  Andreas Keyser; Michael K Hilker; Sebastian Schmidt; Christian von Bary; Wolfgang Zink; Michael Ried; Christof Schmid; Claudius Diez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-12-07

Review 6.  Is programmed electrical stimulation mandatory for recognition of ventricular arrhythmogenicity in heart failure?

Authors:  Srilakshmi Mandayam Adhyapak; Venkateswara Rao Parachuri
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-19

7.  The use of advance directives among patients with implantable cardioverter defibrillators.

Authors:  Tanya H Tajouri; Abigale L Ottenberg; David L Hayes; Paul S Mueller
Journal:  Pacing Clin Electrophysiol       Date:  2012-03-20       Impact factor: 1.976

Review 8.  Microvolt T-wave alternans physiological basis, methods of measurement, and clinical utility--consensus guideline by International Society for Holter and Noninvasive Electrocardiology.

Authors:  Richard L Verrier; Thomas Klingenheben; Marek Malik; Nabil El-Sherif; Derek V Exner; Stefan H Hohnloser; Takanori Ikeda; Juan Pablo Martínez; Sanjiv M Narayan; Tuomo Nieminen; David S Rosenbaum
Journal:  J Am Coll Cardiol       Date:  2011-09-20       Impact factor: 24.094

9.  [We implant too many ICD - contra].

Authors:  M Block
Journal:  Herz       Date:  2016-03       Impact factor: 1.443

10.  ECG quantification of myocardial scar and risk stratification in MADIT-II.

Authors:  Zak Loring; Wojciech Zareba; Scott McNitt; David G Strauss; Galen S Wagner; James P Daubert
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-06-09       Impact factor: 1.468

View more