Ewa Grudzińska1, Monika Modrzejewska1.
Abstract
PURPOSE: To assess pattern electroretinogram (PERG) recordings in patients with axial myopia with a special focus on the correct interpretation of findings. PATIENTS AND METHODS: Sixty patients divided into three groups according to the spherical equivalent of refractive error (group 1, error -3 D to -6 D; group 2, error > -6 D; and controls, error -1 D to +1 D) were examined. Data for the right eye of every patient were considered in the statistical analysis. All patients had a full ophthalmic examination including the measurement of visual acuity, intraocular pressure, degree of refractive error, axial length, biomicroscopic evaluation of the anterior segment, fundoscopy and PERG. The differences of basic parameters and P50 and N95 amplitudes as well as P50 implicit time between groups were studied. Correlations between P50 and N95 amplitudes and P50 implicit time were axial length and refractive error was established.Entities:
Keywords: N95 amplitude; P50 amplitude; P50 peak time; eyeball length; refractive error
Year: 2021 PMID: 34234404 PMCID: PMC8254556 DOI: 10.2147/OPTH.S308604
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Basic Parameters of the Analyzed Subjects
| Parameter | Controls ± 1.00 D | Moderate Myopia −3.00 to −6.00 D | High Myopia <–6.00 D | F | |
|---|---|---|---|---|---|
| Age | 28.9±0.99 | 28.85±0.99 | 29.1±0.99 | 0.02 | 0.98 |
| Body height (m) | 1.74±0.03 | 1.67±0.03 | 1.67±0.03 | 1.75 | 0.18 |
| Body weight (kg) | 66.7±3.21 | 62.2±2.08 | 67.7±4.28 | 0.78 | 0.46 |
| BMI | 21.69±3.45 | 22.11±2.64 | 22.56±4.18 | 0.31 | 0.73 |
| SBP | 117.75±14.06 | 121.2±12.70 | 121.95±17.93 | 0.44 | 0.65 |
| DBP | 73.25±8.27 | 73.80±10.22 | 75.80±13.31 | 0.30 | 0.74 |
| HR | 68.65±9.26 | 68.70±10.60 | 71.95±7.84 | 0.83 | 0.44 |
Notes: Values in the table are means ±standard deviation.
Abbreviations: BMI, body mass index, SBP, systolic blood pressure, DBP, diastolic blood pressure, HR, heart rate.
Figure 1PERG-traces representative for individuals of the particular group.
Figure 2(A) Correlation of P50 amplitude and AL. (B) Correlation of N95 amplitude and AL. (C) Correlation of P50 implicit time and AL, (D) Correlation between spherical equivalent of refractive error and P50 and N95 amplitude and P50 implicit time.
Parameters Measured in Analyzed Groups
| Parameter | Controls ±1.00 D | Moderate Myopia −3.00 to −6.00 D | High Myopia <–6.00 D | F | |
|---|---|---|---|---|---|
| BCVA | −0.134±0.11 | −0.142±0.22 | −0.005±0.16 | 4.06 | 0.02 |
| Spherical error | 0.125±0.48 | −4.395±0.93 | −7.637±1.71 | 226.85 | <0.001 |
| Cylindrical error | −0.21±0.28 | −0.41±0.44 | −0.95±0.81 | 9.20 | 0.003 |
| SE | 0.03±0.53 | −4.65±0.91 | −8.16±0.42 | 219.00 | <0.001 |
| IOP | 14.82±2.68 | 17.01±1.78 | 16.80±3.19 | 4.27 | 0.02 |
| AL | 23.27±0.78 | 25.17±0.70 | 26.45±1.37 | 51.62 | <0.001 |
| P50 peak time (ms) | 49.85±2.17 | 52.12±2.25 | 52.84±3.16 | 7.38 | 0.001 |
| P50 amplitude | 5.52±1.85 | 4.77±2.01 | 3.71±1.33 | 5.37 | 0.01 |
| N95 amplitude | 7.89±2.44 | 6.92±2.77 | 5.36±1.90 | 5.69 | 0.01 |
| N95/P50 ratio | 1.48±0.22 | 1.48±0.31 | 1.46±0.26 | 0.04 | 0.96 |
Notes: Values in the table are means ± standard deviation.
Abbreviations: BCVA, best corrected visual acuity; SE, spherical equivalent of refractive error; IOP, intraocular pressure; AL, axial length.