Literature DB >> 19850843

Electrophysiological evidence of early functional damage in glaucoma and ocular hypertension.

Rachel V North1, Adrian L Jones, Neville Drasdo, John M Wild, James E Morgan.   

Abstract

PURPOSE: The quantification of early retinal ganglion cell damage in ocular hypertension and glaucoma.
METHODS: Thirty subjects under treatment for open-angle glaucoma, 23 subjects with ocular hypertension, and 28 healthy subjects in a control group were investigated by monocular pattern electroretinogram (ERG), L&M (long and medium wavelength) cone ERG, and S (short wavelength)-cone ERG. The diagnosis of glaucoma was based on masked assessment of digital stereoscopic optic nerve head images by three glaucoma specialists. The optic nerve head and retinal nerve fiber layer was assessed by scanning laser ophthalmoscopy and optical coherence tomography.
RESULTS: All types of ERG had reduced mean amplitudes in ocular hypertension and open-angle glaucoma groups compared with the control group. In the ocular hypertension group, the N95 and the L&M-pathway photopic negative response (PhNR) were significantly attenuated (by 19% and 18% compared with the control group, respectively; by 30% and 22%, respectively, in the open-angle glaucoma group compared with the control group). In the subjects with open-angle glaucoma, the pattern ERG P50-N95 was found to be the most sensitive electrophysiological test, and the cup-disc area ratio, when examined by scanning laser ophthalmoscopy, was the most sensitive imaging parameter. Modest but not statistically significant correlations were found between the imaging and electrophysiologic parameters.
CONCLUSIONS: With disc appearance used for the classification of open-angle glaucoma and ocular hypertension, significant electrophysiological losses were found in both conditions. The modest correlation between the structural and electrophysiological measures suggests that these assess different aspects of the pathologic process; electrophysiology can be used to quantify retinal ganglion cell dysfunction that occurs before cell death.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19850843     DOI: 10.1167/iovs.09-3409

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  40 in total

1.  [Electrophysiological examination methods in glaucoma diagnostics].

Authors:  C M Poloschek; M Bach
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

2.  On- and off-response ERGs elicited by sawtooth stimuli in normal subjects and glaucoma patients.

Authors:  Gobinda Pangeni; Robert Lämmer; Ralf P Tornow; Folkert K Horn; Jan Kremers
Journal:  Doc Ophthalmol       Date:  2012-03-29       Impact factor: 2.379

Review 3.  Neurodegeneration in glaucoma: progression and calcium-dependent intracellular mechanisms.

Authors:  S D Crish; D J Calkins
Journal:  Neuroscience       Date:  2010-12-25       Impact factor: 3.590

4.  Oxygen saturation measurements of the retinal vasculature in treated asymmetrical primary open-angle glaucoma using hyperspectral imaging.

Authors:  D J Mordant; I Al-Abboud; G Muyo; A Gorman; A R Harvey; A I McNaught
Journal:  Eye (Lond)       Date:  2014-07-25       Impact factor: 3.775

5.  Intensity response function of the photopic negative response (PhNR): effect of age and test-retest reliability.

Authors:  Nabin R Joshi; Emma Ly; Suresh Viswanathan
Journal:  Doc Ophthalmol       Date:  2017-05-15       Impact factor: 2.379

6.  Reflectance speckle of retinal nerve fiber layer reveals axonal activity.

Authors:  Xiang-Run Huang; Robert W Knighton; Ye Zhou; Xiao-Peng Zhao
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-04-12       Impact factor: 4.799

7.  Electroretinography in idiopathic intracranial hypertension: comparison of the pattern ERG and the photopic negative response.

Authors:  Jason C Park; Heather E Moss; J Jason McAnany
Journal:  Doc Ophthalmol       Date:  2017-11-14       Impact factor: 2.379

8.  Photopic negative response using a handheld mini-ganzfeld stimulator in healthy adults: normative values, intra- and inter-session variability.

Authors:  Adriana Berezovsky; Rustum Karanjia; Arthur Gustavo Fernandes; Gabriel Izan Santos Botelho; Tatiane Luana Novele Bueno; Nívea Nunes Ferraz; Paula Yuri Sacai; Stuart Glenn Coupland; Alfredo Arrigo Sadun; Solange Rios Salomão
Journal:  Doc Ophthalmol       Date:  2020-07-17       Impact factor: 2.379

9.  Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.

Authors:  Barbara Cvenkel; Maja Sustar; Darko Perovšek
Journal:  Doc Ophthalmol       Date:  2017-05-31       Impact factor: 2.379

10.  Pattern ERG and RNFL thickness in hypertensive eyes with normal blue-yellow visual field.

Authors:  Maurizio G Uva; Massimo Di Pietro; Antonio Longo; Katia Lauretta; Michele Reibaldi; Alfredo Reibaldi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08-12       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.