Literature DB >> 11518455

Values of electroretinogram responses according to axial length.

C A Westall1, H S Dhaliwal, C M Panton, D Sigesmun, A V Levin, K K Nischal, E Héon.   

Abstract

Accurate interpretation of electroretinograms (ERGs) requires knowledge of effects of axial myopia on ERG responses. Our purpose was to derive expected changes of ERG responses according to axial length, to stimulus conditions that conform to the International Society for Clinical Electrophysiology of Vision (ISCEV) Standard for Electroretinography. ERGs from 60 subjects were recorded. The subjects were assigned to one of three groups according to the level of myopia. Thirty-three subjects had high myopia (-6.00 D to -14.50 D; mean age, 31 years), eight had mild myopia (-3.00 D to -5.00; mean age, 28 years), and 19 had a small refractive error (+0.75 D to -2.75 D; mean age, 27 years). No subjects had myopic retinopathy. Stimulus-response curves were fitted to dark-adapted b-wave amplitudes and maximum amplitude and semi-saturation constants derived. Axial lengths, measured with A scan ultrasound, ranged from 22.2 mm to 30.0 mm. Analysis of variance and post hoc t-tests revealed significant difference between subjects with high myopia and subjects with small refractive error for ERG amplitude data. There were no significant differences between the three groups for implicit times, the ratio of b- to a-wave and semi-saturation constant. There is linear reduction in the logarithmic transform of ERG amplitude with increasing axial length, related more to axial length than refractive error. We provide relative slope and intercept values, allowing labs to derive expected ERG amplitudes according to axial length. These derivations are valid for persons with no retinopathy.

Entities:  

Mesh:

Year:  2001        PMID: 11518455     DOI: 10.1023/a:1017535207481

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  19 in total

1.  Standardized full-field electroretinography. Normal values and their variation with age.

Authors:  D G Birch; J L Anderson
Journal:  Arch Ophthalmol       Date:  1992-11

2.  Cone electroretinogram to chromatic stimuli in myopic eyes.

Authors:  S Yamamoto; K Nitta; M Kamiyama
Journal:  Vision Res       Date:  1997-08       Impact factor: 1.886

Review 3.  Oscillatory potentials in the retina: what do they reveal.

Authors:  L Wachtmeister
Journal:  Prog Retin Eye Res       Date:  1998-10       Impact factor: 21.198

4.  Rod and cone dysfunction in carriers of X-linked retinitis pigmentosa.

Authors:  N S Peachey; G A Fishman; D J Derlacki; K R Alexander
Journal:  Ophthalmology       Date:  1988-05       Impact factor: 12.079

5.  Experiences with the international standard for clinical electroretinography: normative values for clinical practice, interindividual and intraindividual variations and possible extensions.

Authors:  P C Jacobi; K D Miliczek; E Zrenner
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

6.  Retinal function in high refractive error assessed electroretinographically.

Authors:  I Perlman; E Meyer; T Haim; S Zonis
Journal:  Br J Ophthalmol       Date:  1984-02       Impact factor: 4.638

7.  Ophthalmic changes from age of 10 to 18 years. A longitudinal study of sequels to low birth weight. IV. Ultrasound oculometry of vitreous and axial length.

Authors:  H C Fledelius
Journal:  Acta Ophthalmol (Copenh)       Date:  1982-06

8.  Electrical activity of the eye in high myopia.

Authors:  R K Blach; B Jay; H Kolb
Journal:  Br J Ophthalmol       Date:  1966-11       Impact factor: 4.638

9.  Glasgow Acuity Cards: a new test for the measurement of letter acuity in children.

Authors:  P V McGraw; B Winn
Journal:  Ophthalmic Physiol Opt       Date:  1993-10       Impact factor: 3.117

View more
  38 in total

1.  Influence of axial length of normal eyes on PERG.

Authors:  Rudy Hidajat; Jan Mclay; Celeste Burley; Mark Elder; Jason Morton; David Goode
Journal:  Doc Ophthalmol       Date:  2003-09       Impact factor: 2.379

2.  The relationship between stimulus intensity and response amplitude for the photopic negative response of the flash electroretinogram.

Authors:  A M Binns; K E Mortlock; R V North
Journal:  Doc Ophthalmol       Date:  2011-01-18       Impact factor: 2.379

3.  Full-field electroretinogram findings in children in the atropine treatment for myopia (ATOM2) study.

Authors:  Audrey Chia; Wen Li; Donald Tan; Chi D Luu
Journal:  Doc Ophthalmol       Date:  2013-01-05       Impact factor: 2.379

4.  Reduction of Rod and Cone Function in 6.5-Year-Old Children Born Extremely Preterm.

Authors:  Anna E C Molnar; Sten O Andréasson; Eva K B Larsson; Hanna M Åkerblom; Gerd E Holmström
Journal:  JAMA Ophthalmol       Date:  2017-08-01       Impact factor: 7.389

5.  Retinal dysfunction and high myopia in association with 48,XXYY syndrome.

Authors:  Michael Karampelas; Jessica Gardner; Graham Holder; Alison Hardcastle; Andrew Webster
Journal:  Doc Ophthalmol       Date:  2013-09-19       Impact factor: 2.379

6.  Whole-exome sequencing identifies LRIT3 mutations as a cause of autosomal-recessive complete congenital stationary night blindness.

Authors:  Christina Zeitz; Samuel G Jacobson; Christian P Hamel; Kinga Bujakowska; Marion Neuillé; Elise Orhan; Xavier Zanlonghi; Marie-Elise Lancelot; Christelle Michiels; Sharon B Schwartz; Béatrice Bocquet; Aline Antonio; Claire Audier; Mélanie Letexier; Jean-Paul Saraiva; Tien D Luu; Florian Sennlaub; Hoan Nguyen; Olivier Poch; Hélène Dollfus; Odile Lecompte; Susanne Kohl; José-Alain Sahel; Shomi S Bhattacharya; Isabelle Audo
Journal:  Am J Hum Genet       Date:  2012-12-13       Impact factor: 11.025

7.  TRPM1 mutations are associated with the complete form of congenital stationary night blindness.

Authors:  Makoto Nakamura; Rikako Sanuki; Tetsuhiro R Yasuma; Akishi Onishi; Koji M Nishiguchi; Chieko Koike; Mikiko Kadowaki; Mineo Kondo; Yozo Miyake; Takahisa Furukawa
Journal:  Mol Vis       Date:  2010-03-12       Impact factor: 2.367

8.  RP2 and RPGR mutations and clinical correlations in patients with X-linked retinitis pigmentosa.

Authors:  Dror Sharon; Michael A Sandberg; Vivian W Rabe; Melissa Stillberger; Thaddeus P Dryja; Eliot L Berson
Journal:  Am J Hum Genet       Date:  2003-10-16       Impact factor: 11.025

9.  Evaluation of structural and functional changes in non-pathologic myopic fundus using multifocal electroretinogram and optical coherence tomography.

Authors:  Saemi Park; Seung Hoon Kim; Tae Kwann Park; Young-Hoon Ohn
Journal:  Doc Ophthalmol       Date:  2013-03-08       Impact factor: 2.379

10.  Photopic ON- and OFF-responses in complete type of congenital stationary night blindness in relation to stimulus intensity.

Authors:  Maja Sustar; Branka Stirn-Kranjc; Marko Hawlina; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2007-11-18       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.