Literature DB >> 18374925

Passive flow control of bileaflet mechanical heart valve leakage flow.

Lakshmi P Dasi1, David W Murphy, Ari Glezer, Ajit P Yoganathan.   

Abstract

Blood damage and platelet activation are inherent problems with present day mechanical heart valve designs. We investigate the approach of passive flow control applied to bileaflet mechanical heart valve (BMHV) flows as a means of optimizing leakage flow hemodynamics at length scales relevant to blood damage and platelet activation. Rectangular and hemispherical vortex generator (VG) arrays were mounted on the downstream surfaces of a 25 mm St. Jude Medical valve adjacent to the b-datum leaflet edge (central line where the two leaflets touch in closed position). The effect of VGs on the flow structure emanating from the b-datum line under both pulsatile and steady flow conditions was measured using high resolution particle image velocimetry technique. The VGs were seen to spatially disperse and dissipate the coherent leakage jet structure emanating from the b-datum line. This resulted in a significant diminution of turbulence stresses, particularly with the rectangular VG configuration. This study shows that passive flow control techniques deployed on BHMVs is potentially beneficial as significant control of flow at small length scales may be achieved without altering large scale designs of the valve.

Entities:  

Mesh:

Year:  2008        PMID: 18374925     DOI: 10.1016/j.jbiomech.2008.01.024

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.

Authors:  Megan Heitkemper; Hoda Hatoum; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2019-06-19

2.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

3.  Blood damage through a bileaflet mechanical heart valve: a quantitative computational study using a multiscale suspension flow solver.

Authors:  B Min Yun; Cyrus K Aidun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

4.  Effect of hinge gap width of a St. Jude medical bileaflet mechanical heart valve on blood damage potential--an in vitro micro particle image velocimetry study.

Authors:  Brian H Jun; Neelakantan Saikrishnan; Sivakkumar Arjunon; B Min Yun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-09       Impact factor: 2.097

Review 5.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

6.  Hemodynamic Performance and Thrombogenic Properties of a Superhydrophobic Bileaflet Mechanical Heart Valve.

Authors:  David L Bark; Hamed Vahabi; Hieu Bui; Sanli Movafaghi; Brandon Moore; Arun K Kota; Ketul Popat; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-04-20       Impact factor: 3.934

7.  Hemocompatibility of Super-Repellent surfaces: Current and Future.

Authors:  Sanli Movafaghi; Wei Wang; David L Bark; Lakshmi P Dasi; Ketul C Popat; Arun K Kota
Journal:  Mater Horiz       Date:  2019-05-15       Impact factor: 13.266

8.  A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.

Authors:  Hao Wang; Zhan Cui; Zhongxi Zhou; Zhaoming He
Journal:  Cardiovasc Eng Technol       Date:  2021-06-25       Impact factor: 2.495

9.  Effects of pannus formation on the flow around a bileaflet mechanical heart valve.

Authors:  Woojin Kim; Haecheon Choi; Jihoon Kweon; Dong Hyun Yang; Young-Hak Kim
Journal:  PLoS One       Date:  2020-06-12       Impact factor: 3.240

  9 in total