| Literature DB >> 34146020 |
Sreelakshmi P Amar1, Rajesh Sinha1, Nidhi Kalra1, Tushar Agarwal1, Namrata Sharma1, Jeewan S Titiyal1.
Abstract
Purpose: Lamellar corneal grafts have revolutionized the management of corneal blindness by replacing only the disease specific corneal layers. To the best of our knowledge, there is no study in literature describing the outcomes of bilateral lamellar keratoplasty in the Indian population. The aim of this work was to study the demographic profile, surgical outcomes, and quality of life in patients who underwent bilateral lamellar keratoplasty and to assess the correlation between these three.Entities:
Keywords: Bilateral; deep anterior lamellar keratoplasty; descemet stripping automated endothelial keratoplasty; quality of life
Mesh:
Year: 2021 PMID: 34146020 PMCID: PMC8374770 DOI: 10.4103/ijo.IJO_3194_20
Source DB: PubMed Journal: Indian J Ophthalmol ISSN: 0301-4738 Impact factor: 1.848
Degree of Satisfaction
| Index | Degree of Satisfaction |
|---|---|
| ≥60 | High degree of QLI |
| 50-60 | Average QLI |
| ≤50 | Low QLI |
Surgical Outcome in Patients who underwent Bilateral DALK
| Parameters | Minimum | Maximum | Mean | Sth. Deviation |
|---|---|---|---|---|
| Intra Ocular Pressure (mm Hg) | 10.00 | 24.00 | 15.69 | 3.34 |
| Corneal Thickness (Microns) | 502.00 | 785.00* | 597.15 | 46.17 |
| Contrast sensitivity | 0.00 | 1.65 | 0.94 | 0.49 |
| Specular Count (Cells/mm2) | 943.0 | 3080.00 | 2011.94 | 579.62 |
| Graft Thickness (Microns) | 362.00 | 674.00 | 509.74 | 53.78 |
| Astigmatism (Diopters) | 1.00 | 11.00 | 3.58 | 1.97 |
| Residual Bed Thickness | 30.00 | 179.00 | 90.60 | 36.18 |
*Graft failure due to stromal rejection in one patient
Clinical outcomes in bilateral DSAEK
| Parameters | Minimum | Maximum | Mean | Sth. Deviation |
|---|---|---|---|---|
| Intra Ocular Pressure (mm Hg) | 8.00 | 22.00 | 15.88 | 4.19 |
| Contrast sensitivity | 0.00 | 1.50 | 0.42 | 0.57 |
| Corneal Thickness (microns) | 417.00 | 1320.00 | 668.84 | 180.12 |
| Graft Thickness (microns) | 21.00 | 300.00 | 118.16 | 48.82 |
Distribution of VR-QoL Scores with relation to Postoperative Visual Acuity in the better seeing eye
| DALK | Composite Index (VR-QoL) | Total | ||
|---|---|---|---|---|
| Vision of better eye | <50 | 50-60 | >60 | |
| 6/18-6/6 | 4 | 4 | 18 | 26 |
| 6/60-6/24 | 0 | 2 | 1 | 3 |
| <6/60 | 1 | 1 | 0 | 2 |
| Total | 5 | 7 | 19 | 31 |
|
| ||||
|
|
|
| ||
|
| ||||
| Vision of better eye | <50 | 50-60 | >60 | |
| 6/18-6/6 | 8 | 4 | 0 | 12 |
| 6/60-6/24 | 1 | 0 | 0 | 1 |
| <6/60 | 3 | 0 | 0 | 3 |
| Total | 12 | 4 | 0 | 16 |
| 47 | ||||
Distribution of patients according to Contrast Sensitivity and VR-QoL scores
| VR-QoL Score | Contrast Sensitivity Recorded (log CS) | Total | |
|---|---|---|---|
|
| |||
| <1.0 | >1.0 | ||
| <50 | 12 | 1 | 13 |
| 50-60 | 4 | 7 | 11 |
| >60 | 7 | 16 | 23 |
| Total | 23 | 24 | 47 |