| Literature DB >> 34127531 |
Waqas Ullah1, Mohamed Zghouzi2, Maryam Mukhtar3, Ali Banisad4, Gaith Alhatemi4, Yasar Sattar5, Salman Zahid6, Homam Moussa Pacha7, Delair Gardi4, M Chadi Alraies8.
Abstract
BACKGROUND: The relative safety of percutaneous left ventricular assist device (pVAD) and intra-aortic balloon pump (IABP) in patients with cardiogenic shock after acute myocardial infarction remain unknown.Entities:
Keywords: cardiogenic shock; meta-analysis; myocardial infarction
Year: 2021 PMID: 34127531 PMCID: PMC8204163 DOI: 10.1136/openhrt-2021-001662
Source DB: PubMed Journal: Open Heart ISSN: 2053-3624
Figure 1PRISMA flow diagram of the included studies. RCT, randomised control trial; PRISMA, Preferred ReportingItems for Systematic Reviews and Meta-Analyses.
Baseline characteristics of the included studies
| Author/ | Type of study | Age | Age | Male % | DM | HTN | HLD | Afib | Smoking | MI | PCI | CABG | Mechanical ventilation | Follow-up |
| Gergory/2013 | RCT | 68±11 | 67±11 | 80.6/82 | 3 | |||||||||
| Bochaton/2019 | RCT | 60.3±12.3 | 53.5±8.1 | 85.7/100 | 2/0 | 1/0 | 4/0 | 6 | ||||||
| Schwartz/2011 | OCS | 69.7±10.5 | 67.4±11.4 | 86/58 | 4/32 | 4/34 | 5/28 | 5/28 | 3/18 | 3/6 | 4/11 | 1/7 | 1 | |
| Seyfarth | RCT | 65 | 67 | 62/85 | 5/3 | 7/9 | 8/7 | 7/8 | 12/12 | 1 | ||||
| Ouweneel | RCT | 58±9 | 59±11 | 75/83 | 2/3 | 4/6 | 4/5 | 11/6 | 1/1 | 24/24 | 6 | |||
| Khera | OCS | 69.0±0.4 | 64.7±0.1 | 1.3/0.3 | 46/32 | 70/55 | 57/46 | 16/29 | ||||||
| Pieri | OCS | – | – | – |
Afib, atrial fibrillation; CABG, coronary artery bypass graft; DM, diabetes mellitus; HLD, hyperlipidaemia; HTN, hypertension; IABP, intra-aortic balloon pump; MI, myocardial infarction; OCS, observational cohort study; PCI, percutaneous coronary intervention; pVAD, percutaneous ventricular assist device; RCT, randomised controlled trial.
Figure 7Forest plot for sensitivity analysis of mortality (Khera et al excluded) showing an individual and pooled OR for studies comparing pVAD to IABP in patients with ACS induced cardiogenic shock. pVAD, percutaneous left ventricular assist device;IABP, intra-aortic balloon pump.
Figure 8Funnel plot showing a lower risk of publication bias across studies. (A) Mortality, (B) limb ischaemia, (C) bleeding, (D) cerebrovascular accident, (E) revascularisation.