BACKGROUND: Assessing endocardial strain using a single 13N-ammonia positron emission tomography (PET) scan would be clinically useful, given the association between ischemia and myocardial deformation. However, no software has been developed for strain analysis using PET. We evaluated the clinical potential of feature tracking-derived strain values measured using PET, based on associations with the myocardial flow reserve (MFR). METHODS AND
RESULTS: This retrospective study included 95 coronary artery disease patients who underwent myocardial 13N-ammonia PET. Semi-automatic measurements were made using a feature-tracking technique during myocardial cine imaging, and values were calculated using a 16-segment model. Adenosine-stressed global circumferential strain (CS) and global longitudinal strain (LS) values were compared with global MFR values. Stressed and resting global strain values were also compared. Global strain values were significantly lower in 39 patients with abnormal MFRs [< 2.0] than in 56 patients with normal MFRs [≥ 2.0]. The global CS values in the stressed state were significantly decreased than the resting state values in patients with abnormal MFRs.
CONCLUSIONS: This study applied endocardial feature-tracking to 13N-ammonia PET, and the results suggested that blood flow and myocardial motility could be clinically assessed in ischemic patients using a single PET scan.
© 2021. American Society of Nuclear Cardiology.

Entities:  

Keywords:  13N-ammonia PET; feature-tracking; high-resolution cine imaging; left ventricular strain; myocardial ischemia

Mesh:

Substances:

Year:  2021        PMID: 34117615     DOI: 10.1007/s12350-021-02677-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   3.872


  3 in total

1.  Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT.

Authors:  G Germano; J Erel; H Kiat; P B Kavanagh; D S Berman
Journal:  J Nucl Med       Date:  1997-05       Impact factor: 10.057

2.  Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.

Authors:  Aliasghar Khorsand; Senta Graf; Harald Eidherr; Wolfgang Wadsak; Kurt Kletter; Heinz Sochor; Ernst Schuster; Gerold Porenta
Journal:  J Nucl Med       Date:  2005-12       Impact factor: 10.057

3.  Papillary muscle ischemia on high-resolution cine imaging of nitrogen-13 ammonia positron emission tomography: Association with myocardial flow reserve and prognosis in coronary artery disease.

Authors:  Risako Nakao; Michinobu Nagao; Atsushi Yamamoto; Kenji Fukushima; Eri Watanabe; Shuji Sakai; Nobuhisa Hagiwara
Journal:  J Nucl Cardiol       Date:  2020-06-21       Impact factor: 5.952

  3 in total
  2 in total

1.  13N-ammonia positron emission tomography-derived left-ventricular strain in patients after heart transplantation validated using cardiovascular magnetic resonance feature tracking as reference.

Authors:  Masateru Kawakubo; Michinobu Nagao; Noriko Kikuchi; Atsushi Yamamoto; Risako Nakao; Yuka Matsuo; Koichiro Kaneko; Eri Watanabe; Masayuki Sasaki; Shinichi Nunoda; Shuji Sakai
Journal:  Ann Nucl Med       Date:  2021-10-13       Impact factor: 2.668

2.  BMIPP SPECT in cardiac sarcoidosis: A marker of risk?

Authors:  Roxana Campisi; María Fernanda Merani; Marina I Rodríguez
Journal:  J Nucl Cardiol       Date:  2021-04-26       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.