Literature DB >> 34117383

Clinical outcomes with a low add multifocal and an extended depth of focus intraocular lenses both implanted with mini-monovision.

Mehmet Orkun Sevik1, Semra Akkaya Turhan2, Ebru Toker2.   

Abstract

OBJECTIVES: To compare the visual acuity, contrast sensitivity (CS), spectacle needs, photic phenomena, and quality of life parameters of patients bilaterally implanted with a low add multifocal (MIOL) or an extended depth of focus (EDOF) intraocular lens (IOL), both with intended mini-monovision.
METHODS: In this prospective, randomized, comparative study, patients were randomized to receive either Tecnis +2.75 D (ZKB00) (MIOL Group, n = 15) or Tecnis Symfony (ZXR00) (EDOF Group, n = 14) for bilateral implantation with mini-monovision (-0.50 D). Binocular logMAR uncorrected visual acuities (UVA), monocular defocus curves, CS with CSV 1000-E, and Pelli-Robson Test (PRT), spectacle needs and quality of life parameters with NEI RQL-42 questionnaire were evaluated at postoperative 1, 3, and 6 months.
RESULTS: Results of MIOL and EDOF Groups at postoperative month 6 are as follows: distance (6 m) UVA -0.03 ± 0.05 and -0.05 ± 0.06 (p = 0.938), intermediate (60 cm) UVA, 0.04 ± 0.08 and -0.03 ± 0.07 (p = 0.046); near (40 cm) UVA, 0.22 ± 0.08 and 0.15 ± 0.07 (p = 0.046); near spectacle needs, 26.7% and 14.3% (p > 0.05), respectively. Better visual acuity was achieved in the EDOF Group between the defocus range of -0.50 and -1.75 D (p < 0.05). No significant difference was found regarding photic phenomena and CS evaluated with CSV 1000-E between the two IOL groups at 6 months after surgery (otherwise there are differences at 1 and 3 months in favor of EDOF). However, EDOF Group performed better in mesopic CS evaluated with PRT (p < 0.05).
CONCLUSIONS: When implanted with mini-monovision better binocular uncorrected visual performance at intermediate and near distances achieved with EDOF than low add MIOL.
© 2021. The Author(s), under exclusive licence to The Royal College of Ophthalmologists.

Entities:  

Mesh:

Year:  2021        PMID: 34117383      PMCID: PMC9151652          DOI: 10.1038/s41433-021-01600-3

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   4.456


  37 in total

1.  Extending the range of vision using diffractive intraocular lens technology.

Authors:  Henk A Weeber; Sieger T Meijer; Patricia A Piers
Journal:  J Cataract Refract Surg       Date:  2015-12       Impact factor: 3.351

2.  Optical quality differences between three multifocal intraocular lenses: bifocal low add, bifocal moderate add, and trifocal.

Authors:  David Madrid-Costa; Javier Ruiz-Alcocer; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  J Refract Surg       Date:  2013-11       Impact factor: 3.573

3.  Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power.

Authors:  Ken Hayashi; Shin-Ichi Manabe; Hideyuki Hayashi
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

4.  Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses.

Authors:  F K Jacobi; J Kammann; K W Jacobi; U Grosskopf; K Walden
Journal:  Arch Ophthalmol       Date:  1999-01

5.  Comparative Analysis of the Clinical Outcomes With a Monofocal and an Extended Range of Vision Intraocular Lens.

Authors:  Emilio Pedrotti; Enrico Bruni; Erika Bonacci; Rosanna Badalamenti; Rodolfo Mastropasqua; Giorgio Marchini
Journal:  J Refract Surg       Date:  2016-07-01       Impact factor: 3.573

6.  Normal values for the Pelli-Robson contrast sensitivity test.

Authors:  M Mäntyjärvi; T Laitinen
Journal:  J Cataract Refract Surg       Date:  2001-02       Impact factor: 3.351

7.  Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk.

Authors:  Mary S A Attia; Gerd U Auffarth; Florian T A Kretz; Tamer Tandogan; Tanja M Rabsilber; Mike P Holzer; Ramin Khoramnia
Journal:  J Refract Surg       Date:  2017-10-01       Impact factor: 3.573

Review 8.  Extended depth of focus intraocular lenses for presbyopia.

Authors:  Sruti S Akella; Viral V Juthani
Journal:  Curr Opin Ophthalmol       Date:  2018-07       Impact factor: 3.761

9.  Normal values for photopic and mesopic letter contrast sensitivity.

Authors:  María Cinta Puell; Catalina Palomo; Celia Sánchez-Ramos; Consuelo Villena
Journal:  J Refract Surg       Date:  2004 Sep-Oct       Impact factor: 3.573

10.  Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision.

Authors:  Jilin Tan; Yan Qin; Changpeng Wang; Shiman Yuan; Jian Ye
Journal:  Clin Ophthalmol       Date:  2019-06-28
View more
  2 in total

1.  Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony.

Authors:  Katarzyna Ewa Nowik; Kamil Nowik; Piotr Kanclerz; Jacek Paweł Szaflik
Journal:  Clin Ophthalmol       Date:  2022-05-26

Review 2.  Small Aperture IC-8 Extended-Depth-of-Focus Intraocular Lens in Cataract Surgery: A Systematic Review.

Authors:  José-María Sánchez-González; María Carmen Sánchez-González; Concepción De-Hita-Cantalejo; Antonio Ballesteros-Sánchez
Journal:  J Clin Med       Date:  2022-08-09       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.