Literature DB >> 3410865

Application of a magnetic tracking device to kinesiologic studies.

K N An1, M C Jacobsen, L J Berglund, E Y Chao.   

Abstract

A magnetic position and orientation tracking system is currently available for the determination of the position and orientation of a sensor relative to a source by utilizing the principle of low-frequency magnetic field technology. The application of this system for biomechanical analysis of human movement is examined in this study. Studies of both planar particle motion and spatial rigid body motion based on Eulerian angle description and screw displacement axis description have been performed. The system has been found to be quite accurate and easy to use, and it would be a useful tool in kinesiologic research.

Entities:  

Mesh:

Year:  1988        PMID: 3410865     DOI: 10.1016/0021-9290(88)90225-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  20 in total

1.  Evaluation of a simulated pivot shift test: a biomechanical study.

Authors:  Lars Engebretsen; Coen A Wijdicks; Colin J Anderson; Benjamin Westerhaus; Robert F LaPrade
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

Review 2.  Glenohumeral motion: review of measurement techniques.

Authors:  A M Hill; A M J Bull; R J Dallalana; A L Wallace; G R Johnson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-13       Impact factor: 4.342

3.  Greater fear of reinjury is related to stiffened jump-landing biomechanics and muscle activation in women after ACL reconstruction.

Authors:  Stephanie M Trigsted; Dane B Cook; Kristen A Pickett; Lisa Cadmus-Bertram; Warren R Dunn; David R Bell
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-26       Impact factor: 4.342

4.  Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing.

Authors:  Liba Sheeran; Valerie Sparkes; Monica Busse; Robert van Deursen
Journal:  Eur Spine J       Date:  2009-12-15       Impact factor: 3.134

5.  In vitro validation and reliability study of electromagnetic skin sensors for evaluation of end range of motion positions of the hip.

Authors:  E A Audenaert; L Vigneron; T Van Hoof; K D'Herde; G van Maele; D Oosterlinck; C Pattyn
Journal:  Med Biol Eng Comput       Date:  2011-07-13       Impact factor: 2.602

6.  Chronic anterior pallidal stimulation for Parkinson's disease.

Authors:  R P Iacono; R R Lonser; G Maeda; S Kuniyoshi; D Warner; G Mandybur; S Yamada
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

7.  A comparison of kinematic recording instruments.

Authors:  R H Eckhouse; M A Penny; R A Maulucci
Journal:  J Med Syst       Date:  1996-12       Impact factor: 4.460

8.  A three-dimensional finite element model of the radiocarpal joint: distal radius fracture step-off and stress transfer.

Authors:  Donald D Anderson; Balachandra R Deshpande; Thomas E Daniel; Mark E Baratz
Journal:  Iowa Orthop J       Date:  2005

9.  Measurement of the time course of bending of the back in the sagittal plane.

Authors:  A P Menezes; K E Davies; D W Hukins; M I Jayson
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

10.  Kinematic evaluation of the modified Weaver-Dunn acromioclavicular joint reconstruction.

Authors:  Robert F LaPrade; Daren J Wickum; Chad J Griffith; Paula M Ludewig
Journal:  Am J Sports Med       Date:  2008-06-06       Impact factor: 6.202

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.