Literature DB >> 3406541

Optics of the eye with air or silicone oil.

E Stefánsson1, J Tiedeman.   

Abstract

Replacement of intraocular contents with gas or silicone oil changes the optical characteristics of the eye. This affects the surgeon's view of the fundus and the patient's vision. Gullstrand's schematic eye was used to calculate the refractive properties of eyes with air or silicone oil in the vitreous cavity or anterior chamber in phakia, aphakia, and pseudophakia. The article gives a general solution of the optical characteristics of the eye with any substance filling the eye or the vitreous cavity. Criteria are shown for selection of appropriate corneal contact lenses for visualization of the fundus during and after vitreous surgery.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3406541     DOI: 10.1097/00006982-198808010-00004

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  6 in total

1.  Retinal detachment in AIDS: long-term results after repair with silicone oil.

Authors:  A R Irvine; L Lonn; D Schwartz; M Zarbin; F Ballesteros; S Kroll
Journal:  Br J Ophthalmol       Date:  1997-03       Impact factor: 4.638

Review 2.  Lasers, optical systems and safety in ophthalmology: a review.

Authors:  F Fankhauser; U Dürr; H Giger; P Rol; S Kwasniewska
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-08       Impact factor: 3.117

3.  Biometry and refractive outcome of eyes filled with silicone oil by standardized echography and partial coherence interferometry.

Authors:  Johannes Nepp; Katharina Krepler; Kerstin Jandrasits; Wolfgang Hauff; Georg Hanselmayer; Michaela Velikay-Parel; Karl C Ossoinig; Andreas Wedrich
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-10-20       Impact factor: 3.117

Review 4.  Novel techniques in scleral buckling.

Authors:  P Mahesh Shanmugam; Rajesh Ramanjulu; K C Divyansh Mishra; Pradeep Sagar
Journal:  Indian J Ophthalmol       Date:  2018-07       Impact factor: 1.848

5.  Refractive outcomes of a single-step and a two-step approach for silicone oil removal and cataract surgery.

Authors:  V G Madanagopalan; Pradeep Susvar; M Arthi
Journal:  Indian J Ophthalmol       Date:  2019-05       Impact factor: 1.848

6.  Changes in ocular biometric measurements after vitrectomy with silicone oil tamponade for rhegmatogenous retinal detachment repair.

Authors:  Rui Liu; Qingchen Li
Journal:  BMC Ophthalmol       Date:  2020-09-02       Impact factor: 2.209

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.