| Literature DB >> 34062996 |
Carmen Fava1, Simona Bernardi2, Enrico Marco Gottardi3, Roberta Lorenzatti3, Laura Galeotti4, Francesco Ceccherini4, Francesco Cordoni4, Filomena Daraio3, Emilia Giugliano3, Aleksandar Jovanovski1, Jessica Petiti1, Marta Varotto5, Davide Barberio5, Giovanna Rege-Cambrin3, Paola Berchialla1, Veronica Sciannameo6, Michele Malagola2, Giuseppe Saglio1, Domenico Russo2.
Abstract
In recent years, the digital polymerase chain reaction has received increasing interest as it has emerged as a tool to provide more sensitive and accurate detection of minimal residual disease. In order to start the process of data alignment, we assessed the consistency of the BCR-ABL1 quantification results of the analysis of 16 RNA samples at different levels of disease. The results were obtained by two different laboratories that relied on The Qx100/Qx200 Droplet Digital PCR System (Bio-Rad) and Quant Studio 3D dPCR System (Thermofisher) platforms. We assessed the compatibility between the estimated values by linear regression, Bland-Altman bias-plot, and Mann-Whitney nonparametric test. The results confirmed the compatibility of the measures, allowing us tocompute an 'alignment factor' (AF), equal to 1.41, which was further validated by a different series of experiments. We conclude that the performed measurements by the two laboratories are comparable, and also equalized through the introduction of an alignment factor.Entities:
Keywords: CML; chronic myeloid leukemia; dPCR; digital PCR; digital polymerase chain reaction; minimal residual disease
Year: 2021 PMID: 34062996 PMCID: PMC8161814 DOI: 10.3390/diseases9020035
Source DB: PubMed Journal: Diseases ISSN: 2079-9721
Figure 1Method of combination of replicates from the twolaboratories. The set of measures iscreatedby combiningeach measure from Lab 1 (A) with each measure from Lab 2 (B).
Figure 2Bias plot of Lab1/Lab2 for Exp1. The difference between the two corresponding datasetsare plotted versus their average value. The blue line represents the mean value of thedifferences (d) (where each difference is defined as log10(B) − log10(A)), and the red lines define the 95% limits of agreement.
Figure 3Bias plot of Lab1/Lab2 for Exp2. The difference between the two corresponding datasetsare plotted versus their average value.The blue line represents the mean value of thedifferences (d) (where each difference is defined as log10(B) − log10(A)), and the red lines define the 95% limits of agreement before conversion (left panel) and after conversion (right panel).
Standard deviation (σ) and mean of the differences (d) before and after conversion for Exp1, Exp2, Exp3, and Exp4.
| Standard Deviation (σ) | d before AF | d after AF | |
|---|---|---|---|
| Exp 1 | 0.17 | 0.150 | 0.000 |
| Exp 2 | 0.29 | 0.135 | –0.014 |
| Exp 3 | 0.20 | 0.240 | 0.090 |
| Exp 4 | 0.17 | 0.209 | 0.060 |
Percentages of measurements, before and after conversion, that lie within a 2-, 3-, and 5-fold range for Exp2, Exp3, and Exp4 presented under (A), (B), and (C) respectively.
| (A) | |||
| Exp 2 | 2-Fold | 3-Fold | 5-Fold |
| Before conversion | 79.1 | 87.2 | 96.5 |
| After conversion | 74.4 | 87.2 | 97.7 |
| (B) | |||
| Exp 3 | 2-Fold | 3-Fold | 5-Fold |
| Before conversion | 78.6 | 94.0 | 95.2 |
| After conversion | 91.7 | 95.2 | 96.4 |
| (C) | |||
| Exp 4 | 2-Fold | 3-Fold | 5-Fold |
| Before conversion | 80.7 | 95.4 | 96.6 |
| After conversion | 95.4 | 95.4 | 97.7 |
Fold difference (FD) before (A) and after conversion (B). We report the 95% limits ofagreement, the mean of the ‘fold differences’ (FD = B/A), and the median value for each experiment.
| (A) | |||
| Mean | 95% Limits of Agreement | Median | |
| Exp 2 | 1.81 | 0.37–5.01 | 1.16 |
| Exp 3 | 2.01 | 0.71–4.25 | 1.69 |
| Exp 4 | 1.80 | 0.74–3.51 | 1.40 |
| (B) | |||
| Mean | 95% Limits of Agreement | Median | |
| Exp 2 | 1.28 | 0.26–3.54 | 0.82 |
| Exp 3 | 1.43 | 0.50–3.01 | 1.20 |
| Exp 4 | 1.27 | 0.53–2.49 | 0.99 |
Figure 4Means and corresponding 95% limits of agreement of the fold differences for Exp2, Exp3, and Exp4 before conversion (left panel) and after conversion (right panel).