| Literature DB >> 34054254 |
Aishwarya R Ranbhor1, Ashish J Prabhakar1, Charu Eapen1.
Abstract
BACKGROUND: Stretching has been proven to be effective on pain and range of motion (ROM) in patients with plantar fasciitis. Despite recent gain in popularity and the proposed theories of effectiveness of foam roller, there is a lack of literature on the effect of foam rolling on plantar fasciitis.Entities:
Keywords: Ankle; foam rolling; plantar fasciitis; stretching; trigger points
Year: 2020 PMID: 34054254 PMCID: PMC8158403 DOI: 10.1142/S1013702521500025
Source DB: PubMed Journal: Hong Kong Physiother J ISSN: 1013-7025
Fig. 1.Foam rolling technique for (a) calf muscles and (b) plantar fascia.
Fig. 2.The CONSORT flow diagram.
Outcome measures at baseline.
| Variable | Stretching ( | Foam roller ( | |
|---|---|---|---|
| VAS (cm) | 0.754 | ||
| Gastrocnemius PPT (lb) | 0.171 | ||
| Soleus PPT (lb) | 0.521 | ||
| Plantar fasciitis (lb) | 0.307 | ||
| WBLT (cm) | 0.041* |
Notes: *Significant. VAS: visual analog scale and WBLT: weight-bearing lunge test.
Comparison of outcome measures within the stretching group (pre- and post-treatments).
| Stretching ( | |||||
|---|---|---|---|---|---|
| Mean and SD | |||||
| Parameter | Pre-treatment | Post-treatment | Mean difference | Change (%) | |
| VAS (cm) | 2.60 | 48.62 | 0* | ||
| Gastrocnemius PPT (lb) | 2.61 | 32.28 | 0* | ||
| Soleus PPT (lb) | 2.32 | 30.45 | 0* | ||
| Plantar fascia PPT (lb) | 3.23 | 42.65 | 0* | ||
| WBLT (cm) | 1.28 | 10.64 | 0* | ||
Notes: VAS: Visual analog scale, PPT: pressure pain threshold and WBLT: weight-bearing lunge test. The -value has been adjusted by multiplying it by 2. *Highly significant at .
Comparison of outcome measures within the foam roller group (pre- and post-treatments).
| Foam roller ( | |||||
|---|---|---|---|---|---|
| Mean and SD | |||||
| Parameter | Pre-treatment | Post-treatment | Mean difference | Change (%) | |
| VAS (cm) | 3.01 | 54.65 | 0* | ||
| Gastrocnemius PPT (lb) | 3.18 | 45.46 | 0* | ||
| Soleus PPT (lb) | 3.14 | 44.54 | 0* | ||
| Plantar fascia PPT (lb) | 3.12 | 45.70 | 0* | ||
| WBLT (cm) | 1.20 | 10.64 | 0* | ||
Notes: VAS: visual analog scale, PPT: pressure pain threshold and WBLT: weight-bearing lunge test. The -value has been adjusted by multiplying it by 2. *Highly significant at .
Comparison of outcomes between the groups.
| Parameters | Group | Mean difference | SD difference | Change (%) | Median | ||
|---|---|---|---|---|---|---|---|
| VAS (cm) | Stretching | 25 | 2.60 | 1.02 | 48.62 | 2.60 | 0.171 |
| Foam roller | 25 | 3.01 | 1.15 | 54.65 | 2.90 | ||
| Gastrocnemius PPT (lb) | Stretching | 25 | 2.61 | 2.16 | 32.28 | 2.10 | 0.029* |
| Foam roller | 25 | 3.18 | 1.39 | 45.46 | 3.10 | ||
| Soleus PPT (lb) | Stretching | 25 | 2.32 | 1.86 | 30.45 | 1.80 | 0.013* |
| Foam roller | 25 | 3.14 | 1.73 | 44.54 | 3.20 | ||
| Plantar fascia PPT (lb) | Stretching | 25 | 3.23 | 2.21 | 42.65 | 2.20 | 0.372 |
| Foam roller | 25 | 3.18 | 2.75 | 45.70 | 3.60 | ||
| WBLT (cm) | Stretching | 25 | 1.28 | 0.54 | 13.17 | 1 | 0.861 |
| Foam roller | 25 | 1.20 | 0.65 | 10.64 | 1 |
Notes: *Significant.