Alessandro Arrigo1, Gianpiera Gambaro2, Francesco Fasce3, Emanuela Aragona3, Innocente Figini2, Francesco Bandello3. 1. Department of Ophthalmology, IRCCS San Raffaele Scientific Institute, University Vita-Salute San Raffaele, Milan, Italy. alessandro.arrigo@hotmail.com. 2. Unit of Ophthalmology, Valduce Hospital, Como, Italy. 3. Department of Ophthalmology, IRCCS San Raffaele Scientific Institute, University Vita-Salute San Raffaele, Milan, Italy.
Abstract
PURPOSE: Extended depth-of-focus (EDOF) is a promising intraocular lens (IOL) technology for cataract surgery. The aim of the study was to report the real-life experience related to the implant of EDOF AcrySof® IQ Vivity® (Alcon Inc., USA) IOL. METHODS: The study was designed as a interventional, prospective, case series with 3 months of follow-up. Patients needing cataract surgery, without any other kind of ocular diseases, were recruited and implanted with AcrySof® IQ Vivity® IOL. We evaluated the refractive success of this IOL through complete ophthalmologic assessments and the administration of the Quality of Vision test. The main outcome measures were the refractive outcome; far, intermediate, and near vision; and Quality of Vision score. RESULTS: We included 108 eyes (54 patients; age 62 ± 5 years). Intra-operative and post-operative complications were 0%. Thirty out of 100 eyes (28%) required toric IOL. Best-corrected visual acuity improved from 0.4 ± 0.3 LogMAR to 0.0 ± 0.0 LogMAR (p < 0.01). Refractive outcome was very good for far and intermediate visions, whereas a spherical addition of at least + 1.0D was required for near vision. The mean Quality of Vision score was of 15.5 ± 6.5. The most complained visual disturbances were haloes and glares, although resulting well-tolerated. Dynamic pupillometry findings well-correlated with the amount of complained post-operative visual discomforts. CONCLUSIONS: AcrySof® IQ Vivity® IOL is a well-tolerated choice to correct far and intermediate vision. Spectacles are needed to optimize near vision. Our data strongly suggest dynamic pupillometry as a useful investigation to optimize post-operative refractive success.
PURPOSE: Extended depth-of-focus (EDOF) is a promising intraocular lens (IOL) technology for cataract surgery. The aim of the study was to report the real-life experience related to the implant of EDOF AcrySof® IQ Vivity® (Alcon Inc., USA) IOL. METHODS: The study was designed as a interventional, prospective, case series with 3 months of follow-up. Patients needing cataract surgery, without any other kind of ocular diseases, were recruited and implanted with AcrySof® IQ Vivity® IOL. We evaluated the refractive success of this IOL through complete ophthalmologic assessments and the administration of the Quality of Vision test. The main outcome measures were the refractive outcome; far, intermediate, and near vision; and Quality of Vision score. RESULTS: We included 108 eyes (54 patients; age 62 ± 5 years). Intra-operative and post-operative complications were 0%. Thirty out of 100 eyes (28%) required toric IOL. Best-corrected visual acuity improved from 0.4 ± 0.3 LogMAR to 0.0 ± 0.0 LogMAR (p < 0.01). Refractive outcome was very good for far and intermediate visions, whereas a spherical addition of at least + 1.0D was required for near vision. The mean Quality of Vision score was of 15.5 ± 6.5. The most complained visual disturbances were haloes and glares, although resulting well-tolerated. Dynamic pupillometry findings well-correlated with the amount of complained post-operative visual discomforts. CONCLUSIONS: AcrySof® IQ Vivity® IOL is a well-tolerated choice to correct far and intermediate vision. Spectacles are needed to optimize near vision. Our data strongly suggest dynamic pupillometry as a useful investigation to optimize post-operative refractive success.
Entities:
Keywords:
Cataract surgery; EDOF; IOL; Quality of Vision score
Authors: Laureano A Rementería-Capelo; Pilar Lorente; Virginia Carrillo; José M Sánchez-Pina; Javier Ruiz-Alcocer; Inés Contreras Journal: J Ophthalmol Date: 2022-04-28 Impact factor: 1.974