Literature DB >> 33047991

A Comparative Evaluation of Diffractive Trifocal and New Refractive/Extended Depth of Focus Intraocular Lenses for Refractive Lens Exchange.

Kemal Ozulken1, Hasan Kiziltoprak2, Erdem Yuksel3, Tarkan Mumcuoğlu1.   

Abstract

PURPOSE: To evaluate and compare the visual performance and quality of life (QOL) associated with refractive/extended depth of focus (EDOF) intraocular lenses (IOLs) and diffractive trifocal IOLs in refractive lens exchange patients.
MATERIALS AND METHODS: This was a comparative interventional study of patients undergoing implantation of Lucidis (Swiss Advanced Vision, SAV‑IOL SA, Neuchâtel, Switzerland) or AT LISA tri 839MP (Carl Zeiss Meditec AG, Germany) IOLs. Near, intermediate, and distance best corrected and uncorrected visual acuities were collected at 1 and 3 months postoperatively. The vision-related QOL was evaluated 1 and 3 months after surgery, using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire).
RESULTS: A total of 74 patients underwent refractive lens exchange and IOL implantation, with 38 patients in the EDOF group and 36 in the trifocal group. Among all visual acuities, uncorrected near visual acuity was statistically significantly better with the Lucidis IOL at the first month (p = .02) and diminished at the third-month visit (p = .16). When we compared the VF-14 QOL questionnaire scores, reading small print, reading a newspaper or book, and driving at night were statistically significantly better in the Lucidis group at the first month (p = .00, for each). That difference persisted only in driving at night at the third-month visit (p = .04). Reading small print, driving at night, and doing fine handwork were the most difficult tasks in the AT LISA group at the first month, and only driving at night remained so at the third-month visit.
CONCLUSIONS: The refractive results and visual outcomes at all distances of EDOF and trifocal IOLs were highly satisfactory. However, the EDOF design in the Lucidis IOL achieves lower rates of glare in the early period after refractive lens exchange.

Entities:  

Keywords:  extended depth of focus; presbyopia; quality of life; refractive lens exchange; trifocal

Mesh:

Year:  2020        PMID: 33047991     DOI: 10.1080/02713683.2020.1833347

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  2 in total

1.  Extended depth-of-focus (EDOF) AcrySof® IQ Vivity® intraocular lens implant: a real-life experience.

Authors:  Alessandro Arrigo; Gianpiera Gambaro; Francesco Fasce; Emanuela Aragona; Innocente Figini; Francesco Bandello
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-05-29       Impact factor: 3.117

2.  Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study.

Authors:  María T Iradier; Verónica Cruz; Naty Gentile; Priscila Cedano; David P Piñero
Journal:  Clin Ophthalmol       Date:  2021-03-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.