Literature DB >> 3404938

[White noise field campimetry. A new form of perimetric examination].

E Aulhorn1, G Köst.   

Abstract

Patients with circumscribed visual field defects can perceive them while looking at a surface with small black and white spots flickering randomly at high frequency (such as the white-noise field of a TV screen following the end of transmissions for the day). This autonomous perception of scotomata can be used as a screening method, to perform subsequent manual or automatic grid perimetry with the same TV monitor, concentrating on the defective part of the visual field alone. The results of white-noise scotometry used to examine the visual fields of 161 patients are presented. It appears that the test is capable of identifying suprageniculate homonymous hemianopias, since patients either do not observe them at all in the white-noise field or only to a far lesser degree. In addition, the blind spot and some congenital visual field defects are not observed as visual field defects at all in the white-noise field. However, all acquired circumscribed defects caused by lesions of the first, second, or third neuron are readily seen in the white-noise field if the patient is capable of stable fixation.

Entities:  

Mesh:

Year:  1988        PMID: 3404938     DOI: 10.1055/s-2008-1050114

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  8 in total

1.  Rapid assessment of the visual field in glaucoma using an analysis based on multiple correlations.

Authors:  M Gonzalez de la Rosa; J A Reyes; M A Gonzalez Sierra
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1990       Impact factor: 3.117

Review 2.  [Pulsar perimetry. A review and new results].

Authors:  M Gonzalez de la Rosa; M Gonzalez-Hernandez
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

3.  Temporal contrast sensitivity with peripheral and central stimulation in glaucoma diagnosis.

Authors:  I M Velten; M Korth; F K Horn; W M Budde
Journal:  Br J Ophthalmol       Date:  1999-02       Impact factor: 4.638

4.  Pattern noise (PANO): a new automated functional glaucoma test.

Authors:  Sylvain El-Khoury; Thomas Hannen; Diana Carmen Dragnea; Faustin Ngounou; Paul-Rolf Preußner
Journal:  Int Ophthalmol       Date:  2017-08-16       Impact factor: 2.031

5.  Filling-in of the foveal blue scotoma.

Authors:  S Magnussen; L Spillmann; F Stürzel; J S Werner
Journal:  Vision Res       Date:  2001-10       Impact factor: 1.886

6.  Influence of suction cup oculopression on corneal astigmatism.

Authors:  U Schiefer; C Ulrich; W D Ulrich; C Petzel; A Bernd; H Wilhelm
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-02       Impact factor: 3.117

Review 7.  Strategies for improving early detection and diagnosis of neovascular age-related macular degeneration.

Authors:  Pearse A Keane; Gabriella de Salvo; Dawn A Sim; Srini Goverdhan; Rupesh Agrawal; Adnan Tufail
Journal:  Clin Ophthalmol       Date:  2015-02-17

Review 8.  Early detection of age related macular degeneration: current status.

Authors:  Roy Schwartz; Anat Loewenstein
Journal:  Int J Retina Vitreous       Date:  2015-12-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.