Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.

Jaehyeon Park1,2, Ji Woon Yea1,2, Jae Won Park1,2, Se An Oh1,2.   

Abstract

The objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis Tx at our institution between January 2013 and September 2020. A Vac-lok (EZ-FIX®, Arlico Medical Company, South Korea) fixture and an assistive device, based on the region involved, were used to immobilize patients and to increase the inter-fractional setup reproducibility. The difference in the root mean square (RMS) between the 6D ExacTrac and 3D CBCT was -0.75 mm, 0.45 mm, 0.16 mm, and -0.03°; the RMS value was 1.31 mm, 1.06 mm, 0.87 mm, and 0.64°; and the standard deviation was 0.80 mm, 0.72 mm, 0.62 mm, and 0.44° for lateral, longitudinal, vertical, and yaw directions, respectively. The difference in the average RMS between ExacTrac and CBCT was <1.03 mm in the translation direction and <0.47° in the rotational direction; the results were statistically significant in the lateral, longitudinal, and vertical directions, but not in the yaw direction. Thus, it is necessary to verify the ExacTrac image according to the CBCT image.

Entities:  

Year:  2021        PMID: 34043724     DOI: 10.1371/journal.pone.0252234

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  4 in total

1.  Reducing ExacTrac intrafraction imaging uncertainty for prostate stereotactic body radiotherapy using a pre-treatment CBCT.

Authors:  Barry Jordan; Luis Muñoz; Christopher Colyer
Journal:  Phys Eng Sci Med       Date:  2022-04-19

2.  Toward understanding deep learning classification of anatomic sites: lessons from the development of a CBCT projection classifier.

Authors:  Juan P Cruz-Bastida; Erik Pearson; Hania Al-Hallaq
Journal:  J Med Imaging (Bellingham)       Date:  2022-07-25

3.  Shift detection discrepancy between ExacTrac Dynamic system and cone-beam computed tomography.

Authors:  Vivian U Y Chow; Michael L M Cheung; Monica W K Kan; Anthony T C Chan
Journal:  J Appl Clin Med Phys       Date:  2022-02-21       Impact factor: 2.102

4.  Optimized workflow to minimise intra-fractional motion during stereotactic body radiotherapy of spinal metastases.

Authors:  W M vanNiekerk; T Lazeroms; S J Rogers; N Lomax; R A Hälg; V Gajdos; I Özden; E Kessler; O Riesterer
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-09-30