Literature DB >> 34035192

Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.

Han Gyu Kang1, Taiga Yamaya1, Young Been Han2, Seong Hyun Song2, Guen Bae Ko3,4, Jae Sung Lee3,4,5, Seong Jong Hong2,6.   

Abstract

Silicon photomultipliers (SiPMs) are now widely used for positron emission tomography (PET) applications because of their high gain and low noise characteristics. The PET image quality has been improved with the advancement of time-of-flight (TOF) and depth-of-interaction (DOI) measurement techniques. For brain-dedicated PET systems, both TOF and DOI information are beneficial for enhancing the reconstructed PET image quality. In a previous study, we proposed SiPM-based dual-ended readout PET detectors that used a mean time method to achieve coincidence timing resolution (CTR) of 349 ps and DOI resolution of 2.9 mm. However, the coincidence timing resolution (CTR) was worse than 300 ps since the crystal surface and the reflector type were not optimized. This study aimed at investigating the optimal crystal surface treatment and the reflector material to achieve a sub-200 ps CTR and sub-3 mm DOI resolution with a dual-ended readout PET detector using an LYSO crystal (2.9 × 2.9 × 20 mm3). The scintillation light inside the LYSO crystal was read out by two SiPMs using the dual-ended readout method. The CTR and DOI resolution were measured with two different crystal surfaces (polished and saw-cut) and three different reflector material scenarios of ESR without grease (i.e., air coupling), ESR with optical grease and Teflon. We digitized the timing and energy signals by using a V775N TDC module (35 ps bit-1) and V965 QDC module, respectively. The combination of the saw-cut LYSO crystal and the ESR with air coupling resulted in the best CTR (188 ± 32 ps) and DOI resolution (2.9 ± 0.2 mm) with the dual-ended readout configuration. We concluded the dual-ended readout method in combination with the saw-cut crystal and the ESR reflector with air coupling can provide a sub-200 ps CTR and sub-3.0 mm DOI resolution simultaneously.
© 2020 IOP Publishing Ltd.

Entities:  

Keywords:  depth-of-interaction (DOI); dual-ended readout; scintillation detector; silicon photomultiplier (SiPM); time-of-flight (TOF)

Mesh:

Year:  2020        PMID: 34035192     DOI: 10.1088/2057-1976/abc45a

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  7 in total

1.  A high resolution and high detection efficiency depth-encoding detector for brain positron emission tomography based on a 0.75 mm pitch scintillator array.

Authors:  J Du; S R Cherry
Journal:  J Instrum       Date:  2021-05-20       Impact factor: 1.415

2.  Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination.

Authors:  Haithem Bouziri; Catherine M Pepin; Konin Koua; Maher Benhouria; Caroline Paulin; Jinsong Ouyang; Marc Normandin; Jean-François Pratte; Georges El Fakhri; Roger Lecomte; Réjean Fontaine
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-05-04

3.  Study of optical reflectors for a 100ps coincidence time resolution TOF-PET detector design.

Authors:  Andrea Gonzalez-Montoro; Shirin Pourashraf; Min Sun Lee; Joshua W Cates; Craig S Levin
Journal:  Biomed Phys Eng Express       Date:  2021-09-15

4.  Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSO4 Reflector.

Authors:  Junwei Du
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-07-12

5.  Performance evaluation of dual-ended readout PET detectors based on BGO arrays with different reflector arrangements.

Authors:  Junwei Du; Qian Wang; Chih-Chieh Liu; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2021-10-19       Impact factor: 4.174

6.  High resolution detectors for whole-body PET scanners by using dual-ended readout.

Authors:  Zheng Liu; Ming Niu; Zhonghua Kuang; Ning Ren; San Wu; Longhan Cong; Xiaohui Wang; Ziru Sang; Crispin Williams; Yongfeng Yang
Journal:  EJNMMI Phys       Date:  2022-04-21

Review 7.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Authors:  Haewook Park; Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-07-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.