Quantifying Precision Loss in Targeted Metabolomics Based on Mass Spectrometry and Nonmatching Internal Standards.

Arve Ulvik1, Adrian McCann1, Øivind Midttun1, Klaus Meyer1, Keith M Godfrey2, Per M Ueland1.   

Abstract

In mass spectrometry, reliable quantification requires correction for variations in ionization efficiency between samples. The preferred method is the addition of a stable isotope-labeled internal standard (SIL-IS). In targeted metabolomics, a dedicated SIL-IS for each metabolite of interest may not always be realized due to high cost or limited availability. We recently completed the analysis of more than 70 biomarkers, each with a matching SIL-IS, across four mass spectrometry-based platforms (one GC-MS/MS and three LC-MS/MS). Using data from calibrator and quality control samples added to 60 96-well trays (analytical runs), we calculated analytical precision (CV) retrospectively. The use of integrated peak areas for all metabolites and internal standards allowed us to calculate precision for all matching analyte (A)/SIL-IS (IS) pairs as well as for all nonmatching A/IS pairs within each platform (total n = 1442). The median between-run precision for matching A/IS across the four platforms was 2.7-5.9%. The median CV for nonmatching A/IS (corresponding to pairing analytes with a non-SIL-IS) was 2.9-10.7 percentage points higher. Across all platforms, CVs for nonmatching A/IS increased with increasing difference in retention time (Spearman's rho of 0.17-0.93). The CV difference for nonmatching vs matching A/IS was often, but not always, smaller when analytes and internal standards were close structural analogs.

Entities:  

Mesh:

Year:  2021        PMID: 34014078      PMCID: PMC7611570          DOI: 10.1021/acs.analchem.1c00119

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  29 in total

Review 1.  Pitfalls associated with the use of liquid chromatography-tandem mass spectrometry in the clinical laboratory.

Authors:  Michael Vogeser; Christoph Seger
Journal:  Clin Chem       Date:  2010-05-28       Impact factor: 8.327

2.  Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis.

Authors:  B K Matuszewski
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2005-11-23       Impact factor: 3.205

3.  Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not?

Authors:  Ellen Stokvis; Hilde Rosing; Jos H Beijnen
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

4.  Does a stable isotopically labeled internal standard always correct analyte response? A matrix effect study on a LC/MS/MS method for the determination of carvedilol enantiomers in human plasma.

Authors:  Sherry Wang; Matthew Cyronak; Eric Yang
Journal:  J Pharm Biomed Anal       Date:  2006-09-07       Impact factor: 3.935

Review 5.  Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry.

Authors:  Fabio Gosetti; Eleonora Mazzucco; Davide Zampieri; Maria Carla Gennaro
Journal:  J Chromatogr A       Date:  2009-12-02       Impact factor: 4.759

6.  Systematic investigation of ion suppression and enhancement effects of fourteen stable-isotope-labeled internal standards by their native analogues using atmospheric-pressure chemical ionization and electrospray ionization and the relevance for multi-analyte liquid chromatographic/mass spectrometric procedures.

Authors:  Daniela Remane; Dirk K Wissenbach; Markus R Meyer; Hans H Maurer
Journal:  Rapid Commun Mass Spectrom       Date:  2010-04-15       Impact factor: 2.419

7.  Development and application of time staggered/mass staggered-globally optimized targeted mass spectrometry.

Authors:  Fanyi Zhong; Mengyang Xu; Jiangjiang Zhu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2019-04-28       Impact factor: 3.205

8.  Limitations of deuterium-labeled internal standards for quantitative electrospray ionization mass spectrometry analysis of fatty acid metabolites.

Authors:  Suzumi M Tokuoka; Atsushi Yasumoto; Yoshihiro Kita; Takao Shimizu; Yutaka Yatomi; Yoshiya Oda
Journal:  Rapid Commun Mass Spectrom       Date:  2020-07-15       Impact factor: 2.419

9.  Evaluation of ¹³C- and ²H-labeled internal standards for the determination of amphetamines in biological samples, by reversed-phase ultra-high performance liquid chromatography-tandem mass spectrometry.

Authors:  Thomas Berg; Morten Karlsen; Ase Marit Leere Oiestad; Jon Eigill Johansen; Huiling Liu; Dag Helge Strand
Journal:  J Chromatogr A       Date:  2014-04-18       Impact factor: 4.759

10.  Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry.

Authors:  H R Liang; R L Foltz; M Meng; P Bennett
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

View more
  1 in total

1.  Association of plasma kynurenine pathway metabolite concentrations with metabolic health risk in prepubertal Asian children.

Authors:  Karen Mei-Ling Tan; Mya-Thway Tint; Narasimhan Kothandaraman; Fabian Yap; Keith M Godfrey; Yung Seng Lee; Kok Hian Tan; Peter D Gluckman; Yap-Seng Chong; Mary F F Chong; Johan G Eriksson; David Cameron-Smith
Journal:  Int J Obes (Lond)       Date:  2022-02-16       Impact factor: 5.551

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.