Literature DB >> 16310419

Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis.

B K Matuszewski1.   

Abstract

A simple experimental approach for studying and identifying the relative matrix effect (for example "plasma-to-plasma" and/or "urine-to-urine") in quantitative analyses by HPLC-MS/MS is described. Using as a database a large number of examples of methods developed in recent years in our laboratories, the relationship between the precision of standard line slopes constructed in five different lots of a biofluid (for example plasma) and the reliability of determination of concentration of an analyte in a particular plasma lot (or subject) was examined. In addition, the precision of standard line slopes was compared when stable isotope-labeled analytes versus analogs were used as internal standards (IS). Also, in some cases, a direct comparison of standard line slopes was made when different HPLC-MS interfaces (APCI versus ESI) were used for the assay of the same compound, using the same IS and the same sample preparation and chromatographic separation conditions. In selected cases, the precision of standard line slopes in five different lots of a biofluid was compared with precision values determined five times in a single lot. The results of these studies indicated that the variability of standard line slopes in different lots of a biofluid [precision of standard line slopes expressed as coefficient of variation, CV (%)] may serve as a good indicator of a relative matrix effect and, it is suggested, this precision value should not exceed 3-4% for the method to be considered reliable and free from the relative matrix effect liability. Based on the results presented, in order to assess the relative matrix effect in bioanalytical methods, it is recommended to perform assay precision and accuracy determination in five different lots of a biofluid, instead of repeat (n=5) analysis in the same, single biofluid lot, calculate standard line slopes and precision of these slopes, and to use <3-4% slope precision value as a guide for method applicability to support clinical studies. It was also demonstrated that when stable isotope-labeled analytes were used as internal standards, the precision of standard line slopes in five different lots of a biofluid was </=2.4% irrespective of the HPLC-MS interface utilized. This clearly indicated that, in all cases studied, the use of stable isotope-labeled IS eliminated relative matrix effect. Also, the utilization of the APCI interface instead of ESI led to the elimination of the relative matrix effect in all cases studied. When the precision of standard line slope values exceeds the 3-4% limit, the method may require improvements (a more efficient chromatography, a more selective extraction, a stable isotope-labeled IS instead of an analog as an IS, and/or a change in the HPLC-MS interface) to eliminate the relative matrix effect and to improve assay selectivity.

Mesh:

Year:  2005        PMID: 16310419     DOI: 10.1016/j.jchromb.2005.11.009

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  59 in total

1.  Quantitative analysis of therapeutic drugs in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring.

Authors:  Nicholas Edward Manicke; Paul Abu-Rabie; Neil Spooner; Zheng Ouyang; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2011-06-21       Impact factor: 3.109

2.  Multiplex ultra-performance liquid chromatography-tandem mass spectrometry method for simultaneous quantification in human plasma of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, anidulafungin, and caspofungin.

Authors:  Laurent Arthur Decosterd; Bertrand Rochat; Benoît Pesse; Thomas Mercier; Frédéric Tissot; Nicolas Widmer; Jacques Bille; Thierry Calandra; Boris Zanolari; Oscar Marchetti
Journal:  Antimicrob Agents Chemother       Date:  2010-09-20       Impact factor: 5.191

3.  Validation and application of a method for the determination of buprenorphine, norbuprenorphine, and their glucuronide conjugates in human meconium.

Authors:  Sherri L Kacinko; Diaa M Shakleya; Marilyn A Huestis
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

4.  Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters.

Authors:  Jet C Van De Steene; Willy E Lambert
Journal:  J Am Soc Mass Spectrom       Date:  2008-02-07       Impact factor: 3.109

5.  Determination of risperidone and enantiomers of 9-hydroxyrisperidone in plasma by LC-MS/MS.

Authors:  B Cabovska; S L Cox; A A Vinks
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2007-02-15       Impact factor: 3.205

6.  8-Oxo-2'-deoxyguanosine as a biomarker of tobacco-smoking-induced oxidative stress.

Authors:  Clementina Mesaros; Jasbir S Arora; Ashley Wholer; Anil Vachani; Ian A Blair
Journal:  Free Radic Biol Med       Date:  2012-05-18       Impact factor: 7.376

7.  Development and validation of an LC-MS/MS assay for tenofovir and tenofovir alafenamide in human plasma and cerebrospinal fluid.

Authors:  Andrew J Ocque; Colleen E Hagler; Gene D Morse; Scott L Letendre; Qing Ma
Journal:  J Pharm Biomed Anal       Date:  2018-04-23       Impact factor: 3.935

8.  Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies.

Authors:  Dajana Vuckovic; Erasmus Cudjoe; Florin Marcel Musteata; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2010-01-07       Impact factor: 13.491

9.  Development and validation of an LC-MS/MS method for determination of the L-type voltage-gated calcium channel/NMDA receptor antagonist NGP1-01 in mouse serum.

Authors:  Harini Jogiraju; Xiang Zhou; Ashta Lakshmi Prasad Gobburi; Kiran K Pedada; Werner J Geldenhuys; Cornelis J Van der Schyf; Samuel D Crish; David J Anderson
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-06-02       Impact factor: 3.205

10.  Online Sol-gel Capillary Microextraction-Mass Spectrometry (CME-MS) Analysis of Illicit Drugs.

Authors:  Emre Seyyal; Theresa Evans-Nguyen
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-22       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.