Fulvio Colombo1, Giorgio Gentile1, Valerio Vagnoni1, Alessandro Fiorillo2, Pietro Piazza2, Fabrizio Sartorio2, Alessandro Franceschelli1.
Abstract
OBJECTIVE: To evaluate surgical outcomes after implantation of the Zephyr ZSI 475 inflatable penile prosthesis (IPP) and patients' quality of life.Entities:
Keywords: Erectile dysfunction; Implantation; Penile prosthesis; Satisfaction; Zephyr ZSI 475
Year: 2020 PMID: 33996473 PMCID: PMC8099647 DOI: 10.1016/j.ajur.2020.02.002
Source DB: PubMed Journal: Asian J Urol ISSN: 2214-3882
Comparative table: Main characteristics of AMS-Boston, Coloplast and Zephyr surgical implants devices.
| Company | Model | Access | Length (cm) | Cylinders, tubing and coating | Pump and reservoir |
|---|---|---|---|---|---|
| AMS-Boston | AMS 700 LGX™ preconnect | Infrapubic | 12-15-18-21 (AMS 700 LGX) | Three-ply design of the cylinders consisting of an inner silicone layer that abutted a silicone-coated unidirectional woven Dacro-Lycra fabric layer With–without InhibiZone™ coating (antibiotic impregnation rifampicin and minocycline hydrochloride) Kink-resistant tubing | Momentary Squeeze pump (smaller than previous pump and easier deflation due to the quick squeeze button) Lockout valve (within the pump) in order to reduce the risk of auto-inflation Conceal Reservoir (flat reservoir) |
| Coloplast | Titan touch | Infrapubic | 14-16-18-20-22 (Titan touch) | Bioflex® (polyurethane material) allows very good tensile strenght without compromising biocompatibility of the cylinders Soft-molded cylinder tips Hydrophilic coating Zero-degree tubing | Touch pump (single touch button that allows natural deflection of the device) Cloverleaf reservoir (low risk of self-inflation with the block valve ™) |
| Zephyr Surgical Implant | ZSI 475 | Penoscrotal | 12-15-18-21 | Cylinders: three layers (silicone-tissue-silicone) reducing the risk of accidental piercing during the procedure; narrow and flexible proximal portion Hydrophilic PVP coating Armed tubings with a redoubt portion running inside the corpus cavernosum | Pump with open/close valve (reduced risk for mechanical failure), longer exit tube to decrease the risk of breakage and softer valve axle with button to ease deflation Reinforced valve within the pump (low risk of incidental auto-inflation) Reservoir preconnected to pump |
PVP, polyvinylpyrrolidone.
Figure 1ZSI 475 standard size kit.
Figure 2ZSI 475 aspect with flexible rear tips.
Figure 3ZSI 475 Kaplan-Meier overall survival estimate (%).
QoLSPP questionnaire item scores.
| Domains | Item | Valid responses ( | Mean | Median |
|---|---|---|---|---|
| Functional | Prosthesis adequacy | 15 | 4.38 | 5 |
| Ease/simplicity of use | 15 | 4.50 | 5 | |
| Duration of implant | 15 | 4.53 | 5 | |
| Penile rigidity | 15 | 4.00 | 4 | |
| Fulfillment of expectations | 15 | 3.92 | 4 | |
| Personal | Sexual desire | 15 | 4.23 | 4 |
| Liveliness and wit | 15 | 3.76 | 4 | |
| Security | 15 | 3.92 | 4 | |
| Sexual experience | 15 | 4.15 | 4 | |
| Relational | Well-being of the couple | 15 | 3.76 | 4 |
| Frequency of orgasms | 15 | 4.30 | 4 | |
| Frequency of sexual intercourse | 15 | 3.30 | 3 | |
| Partner satisfaction | 15 | 3.53 | 4 | |
| Social | Daily life | 15 | 4.07 | 4 |
| General well-being | 15 | 3.84 | 4 | |
| Feeling like others | 15 | 3.84 | 4 |
QoLSPP, Quality of Life and Sexuality with Penile Prosthesis.