Literature DB >> 33996244

Graph-based rotational nonuniformity correction for localized compliance measurement in the human nasopharynx.

Yusi Miao1,2, Joseph J Jing1, Zhongping Chen1,2,3.   

Abstract

Recent advancements in the high-speed long-range optical coherence tomography (OCT) endoscopy allow characterization of tissue compliance in the upper airway, an indicator of collapsibility. However, the resolution and accuracy of localized tissue compliance measurement are currently limited by the lack of a reliable nonuniform rotational distortion (NURD) correction method. In this study, we developed a robust 2-step NURD correction algorithm that can be applied to the dynamic OCT images obtained during the compliance measurement. We demonstrated the utility of the NURD correction algorithm by characterizing the local compliance of nasopharynx from an awake human subject for the first time.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2021        PMID: 33996244      PMCID: PMC8086476          DOI: 10.1364/BOE.419997

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  29 in total

1.  Correction of rotational distortion for catheter-based en face OCT and OCT angiography.

Authors:  Osman O Ahsen; Hsiang-Chieh Lee; Michael G Giacomelli; Zhao Wang; Kaicheng Liang; Tsung-Han Tsai; Benjamin Potsaid; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Lett       Date:  2014-10-15       Impact factor: 3.776

2.  Investigating in vivo airway wall mechanics during tidal breathing with optical coherence tomography.

Authors:  Claire Robertson; Sang-Won Lee; Yeh-Chan Ahn; Sari Mahon; Zhongping Chen; Matthew Brenner; Steven C George
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

3.  Magnetic resonance elastography of the lungs: A repeatability and reproducibility study.

Authors:  Faisal Fakhouri; Huiming Dong; Arunark Kolipaka
Journal:  NMR Biomed       Date:  2019-05-14       Impact factor: 4.044

4.  Airway compliance measured by anatomic optical coherence tomography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Nicusor Iftimia; Hillel Price; Carlton Zdanski; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2017-03-15       Impact factor: 3.732

5.  Ultrasound Shear-Wave Elastography of the Tongue in Adults with Obstructive Sleep Apnea.

Authors:  Chun-Hsiang Chang; Chih-Chung Huang; Ya-Hui Wang; Fang-Ju Chou; Jeng-Wen Chen
Journal:  Ultrasound Med Biol       Date:  2020-05-10       Impact factor: 2.998

6.  Retropalatal and retroglossal airway compliance in patients with obstructive sleep apnea.

Authors:  Melania Marques; Pedro R Genta; Ali Azarbarzin; Scott A Sands; Luigi Taranto-Montemurro; Ludovico Messineo; David P White; Andrew Wellman
Journal:  Respir Physiol Neurobiol       Date:  2018-06-18       Impact factor: 1.931

7.  Automatic three-dimensional registration of intravascular optical coherence tomography images.

Authors:  Giovanni J Ughi; Tom Adriaenssens; Matilda Larsson; Christophe Dubois; Peter R Sinnaeve; Mark Coosemans; Walter Desmet; Jan D'hooge
Journal:  J Biomed Opt       Date:  2012-02       Impact factor: 3.170

8.  High-speed upper-airway imaging using full-range optical coherence tomography.

Authors:  Joseph Jing; Jun Zhang; Anthony Chin Loy; Brian J F Wong; Zhongping Chen
Journal:  J Biomed Opt       Date:  2012-11       Impact factor: 3.170

Review 9.  Mechanical properties of the upper airway.

Authors:  Kingman P Strohl; James P Butler; Atul Malhotra
Journal:  Compr Physiol       Date:  2012-07       Impact factor: 9.090

10.  Real-Time Elastography for Differentiation of Breast Lesions.

Authors:  Ebru Yılmaz; Ayhan Yılmaz; Ahmet Aslan; Ibrahim Inan; Mujgan Calıskan Evren; Kemal Tekesin
Journal:  Pol J Radiol       Date:  2017-11-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.