Literature DB >> 18071872

Determination of urethral catheter surface lubricity.

Katarzyna Kazmierska1, Maciej Szwast, Tomasz Ciach.   

Abstract

Device for in-vitro measurement of static and kinetic friction coefficient of catheter surface was developed. Tribometer was designed and constructed to work with exchangeable counter-faces (polymers, tissue) and various types of tubes, in wet conditions in order to mimic in-vivo process. Thus seven commercially available urethral catheters, made from vinyl polymers, natural latex with silicone coating, all-silicone or hydrogel coated, and one made from polyvinylchloride with polyurethane/polyvinylpyrrolidone hydrogel coating obtained in our laboratory, were tested against three various counter faces: polymethacrylate (organic glass), inner part of porcine aorta and porcine bladder mucosa. Additionally, the hydrophility/hydrophobity of tested catheters was stated via water wetting contact angle measurement. Super-hydrophilic biomaterials revealed low friction on tissue and hydrophobic counter-face; slightly hydrophobic showed higher friction in both cases, while more hydrophobic manifested low friction on tissue but high on hydrophobic polymer. The smoothest friction characteristic was achieved in all cases on tissue counter-faces. The measured values of the static coefficient of friction of catheters on bladder mucosa counter-face were as follows: the highest (0.15) for vinyl and siliconised latex catheters and 3 folds lower (0.05) for all-silicone ones. Hydrogel coated catheters exhibited the lowest static and kinetic friction factors.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18071872     DOI: 10.1007/s10856-007-3339-4

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  19 in total

Review 1.  Urinary tract biomaterials.

Authors:  Darren T Beiko; Bodo E Knudsen; James D Watterson; Peter A Cadieux; Gregor Reid; John D Denstedt
Journal:  J Urol       Date:  2004-06       Impact factor: 7.450

2.  Friction and lubrication of pleural tissues.

Authors:  Edgardo D'Angelo; Stephen H Loring; Magda E Gioia; Matteo Pecchiari; Claudia Moscheni
Journal:  Respir Physiol Neurobiol       Date:  2004-08-20       Impact factor: 1.931

3.  Biomaterials lubricated for minimum frictional resistance.

Authors:  N Tomita; S Tamai; E Okajima; Y Hirao; K Ikeuchi; Y Ikada
Journal:  J Appl Biomater       Date:  1994

4.  Determination of the coefficient of kinetic friction of urinary catheter materials.

Authors:  A E Khoury; M E Olson; F Villari; J W Costerton
Journal:  J Urol       Date:  1991-03       Impact factor: 7.450

5.  Evaluation of slipperiness of catheter surfaces.

Authors:  G Marmieri; M Pettenati; C Cassinelli; M Morra
Journal:  J Biomed Mater Res       Date:  1996

6.  The importance of osmolality in hydrophilic urethral catheters: a crossover study.

Authors:  L Waller; M Telander; L Sullivan
Journal:  Spinal Cord       Date:  1997-04       Impact factor: 2.772

Review 7.  New developments in ureteral stent design, materials and coatings.

Authors:  Ben H Chew; Mordechai Duvdevani; John D Denstedt
Journal:  Expert Rev Med Devices       Date:  2006-05       Impact factor: 3.166

Review 8.  Materials for urinary catheters: a review of their history and development in the UK.

Authors:  E L Lawrence; I G Turner
Journal:  Med Eng Phys       Date:  2005-03-17       Impact factor: 2.242

9.  Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.

Authors:  J Stensballe; D Looms; P N Nielsen; M Tvede
Journal:  Eur Urol       Date:  2005-08-02       Impact factor: 20.096

10.  The importance of osmolality for intermittent catheterization of the urethra.

Authors:  J Lundgren; O Bengtsson; A Israelsson; A C Jönsson; A S Lindh; J Utas
Journal:  Spinal Cord       Date:  2000-01       Impact factor: 2.772

View more
  4 in total

1.  Frictional properties of light-activated antimicrobial polymers in blood vessels.

Authors:  Polina Prokopovich; Stefano Perni; Clara Piccirillo; Jonathan Pratten; Ivan P Parkin; Michael Wilson
Journal:  J Mater Sci Mater Med       Date:  2009-09-27       Impact factor: 3.896

2.  Contact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion.

Authors:  Ran Hao; E Erdem Tuna; M Cenk Çavuşoğlu
Journal:  J Dyn Syst Meas Control       Date:  2021-02-23       Impact factor: 1.640

3.  Ureteral stents should be soaked for several minutes before placement.

Authors:  Norbert Laube; Chintan Desai; Falk Bernsmann; Christian Fisang
Journal:  Springerplus       Date:  2015-06-09

Review 4.  Effects of hydrophilic coated catheters on urethral trauma, microtrauma and adverse events with intermittent catheterization in patients with bladder dysfunction: a systematic review and meta-analysis.

Authors:  Xi Liao; Yuwei Liu; Shiqi Liang; Ka Li
Journal:  Int Urol Nephrol       Date:  2022-04-21       Impact factor: 2.266

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.