Literature DB >> 33980198

Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials.

Qi Gou1, Xiong Xiong1, Dan Cao2, Yuanliang He3, Xu Li4.   

Abstract

BACKGROUND: The outcomes for volar locking plate (VLP) and external fixation (EF) in distal radius fracture cases remain controversial. The current study of randomized controlled trials (RCTs) aimed to assess VLP and EF, which might benefit distal radius fracture cases.
METHODS: RCTs comparing VLP and EF in distal radius fracture cases, until 18 March 2020, were systematically reviewed and summarized. The functional and radiographic outcomes, together with complications, for distal radius fracture cases, were evaluated.
RESULTS: In total, 12 studies comprising 1205 distal radius fracture cases were included. The VLP group had observed lower disability in the arm shoulder and hand score (DASH) at 3rd, 6th, and 12th -month post-operation, with the mean differences (MDs) of - 10.43 (95 % CI = - 15.77 to - 5.08, P < 0.01), - 3.48 (95 % CI = - 6.37 to - 0.59, P = 0.02), and - 4.13 (95 % CI = - 6.94 to - 1.33, P < 0.01), respectively. The VLP group also had lower visual analog scale scores (VAS) compared to the EF group, with MDs of - 0.10 (95 % CI = - 0.18 to - 0.03, P < 0.01) for the former at 6th -month post-operation. Also, the EF group exhibited better grip strength than that in the VLP group, with MD of 12.48 (95 % CI = 7.00-17.95, P < 0.01) at the 3rd month and 4.54 (95 % CI = 0.31-8.76, P = 0.04) at 6th month. No significant differences in radiographic outcomes were observed between the VLP and EF groups (P > 0.05). The VLP group had a lower complication rate than that in the EF group.
CONCLUSIONS: VLP had a lower DASH score and VAS score but with lower grip strength. No significant differences in radiographic outcomes were observed. VLP had a lower complication rate than that of EF.

Entities:  

Keywords:  Distal radius fractures; External fixation; Meta-analysis; Putcome; RCTs; Volar locking plates

Mesh:

Year:  2021        PMID: 33980198     DOI: 10.1186/s12891-021-04312-7

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  35 in total

Review 1.  A revolution in the management of fractures of the distal radius?

Authors:  N D Downing; A Karantana
Journal:  J Bone Joint Surg Br       Date:  2008-10

2.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

3.  Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation 'versus' locked volar plating.

Authors:  J Jeudy; V Steiger; P Boyer; P Cronier; P Bizot; P Massin
Journal:  Injury       Date:  2011-06-25       Impact factor: 2.586

4.  A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.

Authors:  Jonathon C Wolf; Wayne M Weil; Douglas P Hanel; Thomas E Trumble
Journal:  J Hand Surg Am       Date:  2006-12       Impact factor: 2.230

5.  Epidemiology of fractures in 15,000 adults: the influence of age and gender.

Authors:  B R Singer; G J McLauchlan; C M Robinson; J Christie
Journal:  J Bone Joint Surg Br       Date:  1998-03

6.  A meta-analysis of the literature on distal radius fractures: review of 615 articles.

Authors:  Nader Paksima; Anand Panchal; Martin A Posner; Steven M Green; Charles T Mehiman; Rudi Hiebert
Journal:  Bull Hosp Jt Dis       Date:  2004

7.  Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study.

Authors:  Utku Kandemir; Amir Matityahu; Rohan Desai; Christian Puttlitz
Journal:  J Orthop Trauma       Date:  2008-10       Impact factor: 2.512

8.  Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation.

Authors:  S Kawaguchi; K Sawada; Y Nabeta; M Hayakawa; M Aoki
Journal:  J Hand Surg Am       Date:  1998-09       Impact factor: 2.230

9.  Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year.

Authors:  Maria K T Wilcke; Hassan Abbaszadegan; Per Y Adolphson
Journal:  Acta Orthop       Date:  2011-02-01       Impact factor: 3.717

10.  Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients.

Authors:  Antonio Abramo; Philippe Kopylov; Mats Geijer; Magnus Tägil
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more
  2 in total

1.  Practical Application of the 2020 Distal Radius Fracture AAOS/ASSH Clinical Practice Guideline: A Clinical Case.

Authors:  Robin Neil Kamal; Lauren Michelle Shapiro
Journal:  J Am Acad Orthop Surg       Date:  2022-05-01       Impact factor: 4.000

2.  Conversion from Spanning External Fixation to Open Reduction Internal Fixation Contributes to Healing of Soft Tissues and Fractures in Open Distal Humeral Fractures.

Authors:  Kaige Ma; Donghua Huang; Chunqing Meng; Hong Wang; Zengwu Shao; Huimin Liu; Dehao Fu
Journal:  Med Sci Monit       Date:  2022-03-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.