Literature DB >> 9763273

Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation.

S Kawaguchi1, K Sawada, Y Nabeta, M Hayakawa, M Aoki.   

Abstract

Thirty-three fractures of the distal radius treated with a dynamic external fixator (that allowed for wrist motion between 2 to 4 weeks after surgery) were analyzed, focusing on loss of fracture reduction during external fixation. Fractures with preoperative dorsal angulation greater than 20 degrees and those involving the distal radioulnar joint had a significantly larger loss of reduction of dorsal angulation (8.9 degrees and 6.9 degrees, respectively) than fractures with less severe preoperative dorsal angulation or those with an intact distal radioulnar joint (3.0 degrees and 2.6 degrees, respectively). In contrast, preoperative radial shortening (>2 mm) and involvement of the radiocarpal joint did not significantly increase the loss of dorsal angulation. Neither of the 2 dynamic external fixation systems studied consistently stabilized Colles' fractures with preoperative dorsal angulation of greater than 20 degrees or involvement of the distal radioulnar joint.

Entities:  

Mesh:

Year:  1998        PMID: 9763273     DOI: 10.1016/S0363-5023(98)80174-3

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials.

Authors:  Qiang Fu; Lei Zhu; Peng Yang; Aimin Chen
Journal:  Indian J Orthop       Date:  2018 Nov-Dec       Impact factor: 1.251

2.  Volar locking plate versus external fixation in distal radius fractures: A meta-analysis.

Authors:  Giuseppe Maccagnano; Giovanni Noia; Giovanni Vicenti; Marco Baglioni; Maria Rosa Masciale; Giuseppe Danilo Cassano; Raffaele Vitiello; Biagio Moretti; Vito Pesce
Journal:  Orthop Rev (Pavia)       Date:  2021-03-31

3.  Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials.

Authors:  Qi Gou; Xiong Xiong; Dan Cao; Yuanliang He; Xu Li
Journal:  BMC Musculoskelet Disord       Date:  2021-05-12       Impact factor: 2.362

Review 4.  Internal Versus External Fixation for the Treatment of Distal Radial Fractures: A Systematic Review of Overlapping Meta-Analyses.

Authors:  Qingyu Zhang; Fanxiao Liu; Zhenyun Xiao; Zhenfeng Li; Bomin Wang; Jinlei Dong; Yong Han; Dongsheng Zhou; Jianmin Li
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.