Comparison of margin discrepancy of complete gold crowns fabricated using printed, milled, and conventional hand-waxed patterns.

Sergio Munoz1, Van Ramos2, Douglas P Dickinson3.   

Abstract

STATEMENT OF PROBLEM: The recent application of printing for the fabrication of dental restorations has not been compared and evaluated for margin discrepancy (margin fit) with restorations fabricated using milling and conventional hand-waxing techniques.
PURPOSE: The purpose of this in vitro study was to evaluate and compare margin discrepancy of complete gold crowns (CGCs) fabricated from printed, milled, and conventional hand-waxed patterns.
MATERIAL AND METHODS: Thirty crown patterns were produced by each of 3 different methods: printed by ProJet DP 3000, milled by LAVA CNC 500, and hand waxed, then invested and cast into CGCs. Each crown was evaluated at 10 positions around the margin on the corresponding epoxy die under ×50 light microscopy to determine the mean and maximum margin discrepancy. Measurements were made using a micrometer positioning stage. The results were compared by ANOVA (α=.05).
RESULTS: Milled and hand-waxed patterns were not statistically different from each other (P>.05), while printed patterns produced significantly higher mean and maximum margin discrepancy than milled and hand-waxed patterns (P<.05).
CONCLUSIONS: Relative to margin discrepancy, the LAVA CNC 500 milled and hand-waxed patterns were not significantly different from each other. The ProJet DP 3000 printed patterns were significantly different from LAVA CNC 500 milled and hand-waxed patterns, with an overall poorer result. Fabricating CGCs from printed patterns produced a significantly higher number of crowns with unacceptable margin discrepancy (>120 μm).
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2016        PMID: 27866698     DOI: 10.1016/j.prosdent.2016.09.018

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Interbody Spacer Material Properties and Design Conformity for Reducing Subsidence During Lumbar Interbody Fusion.

Authors:  Lillian S Chatham; Vikas V Patel; Christopher M Yakacki; R Dana Carpenter
Journal:  J Biomech Eng       Date:  2017-05-01       Impact factor: 2.097

2.  Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study).

Authors:  Fatema Khaled Mansour; Rabab Mohammed Ibrahim; Hoda Mansour; Ahmed Mohamed Hamdy
Journal:  BDJ Open       Date:  2021-05-10

3.  Tensile Bond Strength of Three Custom-made Tooth-Colored Implant Superstructures to Titanium Inserts.

Authors:  Mitra Zirak; Mahroo Vojdani; Amir Ali Reza Khaledi; Mitra Farzin
Journal:  J Dent (Shiraz)       Date:  2019-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.