Literature DB >> 33941828

Endodontic length measurements using cone beam computed tomography with dedicated or conventional software at different voxel sizes.

Khoa Van Pham1.   

Abstract

The aim of this study is to investigate the accuracies and the agreements of the 3D Endo software, conventional CBCT software Romexis Viewer at three voxel sizes, and the EAL ProPex Pixi in endodontic length measurements. Three hundred and twenty-nine root canals in 120 intact human extracted molars were accessed. The actual lengths (AL) and electronic lengths (EL) were measured using the ruler and electronic apex locator (EAL), respectively. Teeth were scanned using the CBCT at different voxel sizes (0.075, 0.10, and 0.15 mm). Root canal lengths were measured using 3D Endo with proposed length (3D-PL) by software, corrected length (3D-CL), Romexis Viewer. The Fisher's exact test, paired t-test and Bland-Altman plots were calculated to detect the agreements of the four methods with AL measurements. The ProPex Pixi measurements obtained the highest accuracy in the range of ± 0.5 mm. There was agreement between the 3D-PL and the 3D-CL with AL measurements at voxel size of 0.15 mm and at voxel size of 0.10 mm, respectively. The CBCT Romexis Viewer measurements agreed with AL at three voxel sizes. The conventional CBCT measurements using Romexis Viewer and dedicated software did not reach to the 100% accuracy in the range of ± 0.5 mm.

Entities:  

Year:  2021        PMID: 33941828     DOI: 10.1038/s41598-021-88980-4

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  14 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

Review 2.  Statistical techniques for comparing measurers and methods of measurement: a critical review.

Authors:  John Ludbrook
Journal:  Clin Exp Pharmacol Physiol       Date:  2002-07       Impact factor: 2.557

Review 3.  The fundamental operating principles of electronic root canal length measurement devices.

Authors:  M H Nekoofar; M M Ghandi; S J Hayes; P M H Dummer
Journal:  Int Endod J       Date:  2006-08       Impact factor: 5.264

4.  The Impact of Different Diagnostic Imaging Modalities on the Evaluation of Root Canal Anatomy and Endodontic Residents' Stress Levels: A Clinical Study.

Authors:  Shanon Patel; Risha Patel; Federico Foschi; Franceso Mannocci
Journal:  J Endod       Date:  2019-02-13       Impact factor: 4.171

5.  3D Endo: three-dimensional endodontic treatment planning.

Authors:  Jörg Philipp Tchorz
Journal:  Int J Comput Dent       Date:  2017       Impact factor: 1.883

Review 6.  Cone beam computed tomography in Endodontics - a review.

Authors:  S Patel; C Durack; F Abella; H Shemesh; M Roig; K Lemberg
Journal:  Int Endod J       Date:  2014-04-02       Impact factor: 5.264

Review 7.  Clinical efficacy of electronic apex locators: systematic review.

Authors:  Jorge N R Martins; Duarte Marques; António Mata; João Caramês
Journal:  J Endod       Date:  2014-05-02       Impact factor: 4.171

8.  Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

Authors:  Funda Yılmaz; Kıvanç Kamburoğlu; Buğra Şenel
Journal:  J Endod       Date:  2017-01       Impact factor: 4.171

9.  The Accuracy of a New Cone-beam Computed Tomographic Software in the Preoperative Working Length Determination Ex Vivo.

Authors:  André Vinícius Kaled Segato; Lucila Piasecki; Marcos Felipe Iparraguirre Nuñovero; Ulisses Xavier da Silva Neto; Vânia Portela Ditzel Westphalen; Gianluca Gambarini; Everdan Carneiro
Journal:  J Endod       Date:  2018-04-24       Impact factor: 4.171

10.  Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study.

Authors:  André Luiz Gomide de Morais; Ana Helena Gonçalves de Alencar; Cyntia Rodrigues de Araújo Estrela; Daniel Almeida Decurcio; Carlos Estrela
Journal:  Iran Endod J       Date:  2016-05-01
View more
  1 in total

1.  Root canal length estimated by cone-beam computed tomography at different slice thicknesses, dedicated endodontic software, or measured by an electronic apex locator.

Authors:  Van-Khoa Pham; Tran-Lan-Khue Pham
Journal:  Sci Rep       Date:  2022-04-20       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.