We investigated the role of echocardiographic indices consisting of left ventricular end-diastolic area (LVEDA) in combination with Doppler-derived surrogates of diastolic compliance and filling (E/E', E'/S', E'/A'; early transmitral flow velocity (E), tissue Doppler-derived early (E') diastolic, late (A') diastolic, or peak systolic (S') velocity of the mitral annulus) in predicting fluid responsiveness in off-pump coronary surgery. Hemodynamic and echocardiographic variables were prospectively assessed under general anesthesia before and after a fluid challenge of 6 mL/kg during apnea at atmospheric pressure in 64 patients with LV ejection fraction ≥40%. Forty patients (63%) were fluid responders (≥15% increase in stroke volume index). E/E' and E'/S' could predict fluid responsiveness with area under the receiver operating characteristic curve (AUROC) of 0.71 (95% confidence interval [CI], 0.56-0.85; p = 0.006) and 0.68 (95% CI, 0.54-0.82; p = 0.017), respectively. The combination of LVEDA and E/E' showed incremental predictive ability for fluid responsiveness compared with LVEDA (AUROC, 0.60; p = 0.170) or pulse pressure variation (AUROC, 0.70; p = 0.002), yielding the highest AUROC of 0.78 (95% CI, 0.66-0.90; p < 0.001). The combined index of echocardiographic variables reflecting LV dimension (LVEDA) and diastolic compliance and filling (E/E') is a potentially useful predictor of fluid responsiveness.

Entities:  

Keywords:  Frank-Starling mechanism; cardiac preload; doppler; echocardiography; fluid responsiveness; left ventricular end-diastolic area; stroke volume index

Year:  2021        PMID: 33925449     DOI: 10.3390/jcm10091886

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  25 in total

1.  Clinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures: A comparative simultaneous Doppler-catheterization study.

Authors:  S R Ommen; R A Nishimura; C P Appleton; F A Miller; J K Oh; M M Redfield; A J Tajik
Journal:  Circulation       Date:  2000-10-10       Impact factor: 29.690

2.  Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.

Authors:  Y Song; Y L Kwak; J W Song; Y J Kim; J K Shim
Journal:  Br J Anaesth       Date:  2014-04-09       Impact factor: 9.166

3.  Diastolic Function and Peripheral Venous Pressure as Indices for Fluid Responsiveness in Cardiac Surgical Patients.

Authors:  Nicole R Marques; Johannes De Riese; Bryan C Yelverton; Christopher McQuitty; Daniel Jupiter; Korey Willmann; Michael Salter; Michael Kinsky; William E Johnston
Journal:  J Cardiothorac Vasc Anesth       Date:  2019-01-04       Impact factor: 2.628

4.  Compliance of the left ventricle.

Authors:  H J Levine
Journal:  Circulation       Date:  1972-09       Impact factor: 29.690

Review 5.  Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature.

Authors:  Paul E Marik; Rodrigo Cavallazzi; Tajender Vasu; Amyn Hirani
Journal:  Crit Care Med       Date:  2009-09       Impact factor: 7.598

6.  Potential Usefulness and Clinical Relevance of Adding Left Atrial Strain to Left Atrial Volume Index in the Detection of Left Ventricular Diastolic Dysfunction.

Authors:  Daniel A Morris; Evgeny Belyavskiy; Radhakrishnan Aravind-Kumar; Martin Kropf; Athanasios Frydas; Kerstin Braunauer; Esteban Marquez; Maximilian Krisper; Ruhdja Lindhorst; Engin Osmanoglou; Leif-Hendrik Boldt; Florian Blaschke; Wilhelm Haverkamp; Carsten Tschöpe; Frank Edelmann; Burkert Pieske; Elisabeth Pieske-Kraigher
Journal:  JACC Cardiovasc Imaging       Date:  2017-11-15

7.  Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study.

Authors:  Moritz Wyler von Ballmoos; Jukka Takala; Margareta Roeck; Francesca Porta; David Tueller; Christoph C Ganter; Ralph Schröder; Hendrik Bracht; Bertram Baenziger; Stephan M Jakob
Journal:  Crit Care       Date:  2010-06-11       Impact factor: 9.097

Review 8.  Echocardiography as a guide for fluid management.

Authors:  John H Boyd; Demetrios Sirounis; Julien Maizel; Michel Slama
Journal:  Crit Care       Date:  2016-09-04       Impact factor: 9.097

9.  Whole body ultrasound in the operating room and intensive care unit.

Authors:  André Denault; David Canty; Milène Azzam; Alexander Amir; Caroline E Gebhard
Journal:  Korean J Anesthesiol       Date:  2019-06-04

Review 10.  Management of perioperative volume therapy - monitoring and pitfalls.

Authors:  Michael Sander; Emmanuel Schneck; Marit Habicher
Journal:  Korean J Anesthesiol       Date:  2020-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.