Diastolic Function and Peripheral Venous Pressure as Indices for Fluid Responsiveness in Cardiac Surgical Patients.

Nicole R Marques1, Johannes De Riese2, Bryan C Yelverton2, Christopher McQuitty3, Daniel Jupiter3, Korey Willmann3, Michael Salter3, Michael Kinsky3, William E Johnston2.   

Abstract

OBJECTIVE: Identifying fluid responsiveness is critical to optimizing perfusion while preventing fluid overload. An experimental study of hypovolemic shock resuscitation showed the importance of ventricular compliance and peripheral venous pressure (PVP) on fluid responsiveness. The authors tested the hypothesis that reduced ventricular compliance measured using transesophageal echocardiography results in decreased fluid responsiveness after a fluid bolus.
DESIGN: Prospective observational study.
SETTING: Two-center, university hospital study. PARTICIPANTS: The study comprised 29 patients undergoing elective coronary revascularization. INTERVENTION: Albumin 5%, 7 mL/kg, was infused over 10 minutes to characterize fluid responders (>15% increase in stroke volume) from nonresponders.
MEASUREMENTS AND MAIN RESULTS: Invasive hemodynamics and the ratio of mitral inflow velocity (E-wave)/annular relaxation (e'), or E/e' ratio, were measured using transesophageal echocardiography to assess left ventricular (LV) compliance at baseline and after albumin infusion. Fifteen patients were classified as responders and 14 as nonresponders. The E/e' ratio in responders was 7.4 ± 1.9 at baseline and 7.1 ± 1.8 after bolus. In contrast, E/e' was significantly higher in nonresponders at baseline (10.7 ± 4.6; p = 0.04) and further increased after bolus (12.6 ± 5.5; p = 0.002). PVP was significantly greater in the nonresponders at baseline (14 ± 4 mmHg v 11 ± 3 mmHg; p = 0.02) and increased in both groups after albumin infusion. Fluid responsiveness was tested using the area under the receiver operating characteristic curve and was 0.74 for the E/e' ratio (95% confidence interval 0.55-0.93; p = 0.029) and 0.72 for the PVP (95% confidence interval 0.52-0.92; p = 0.058).
CONCLUSION: Fluid responders had normal LV compliance and lower PVP at baseline. In contrast, nonresponders had reduced LV compliance, which worsened after fluid bolus. E/e,' more than PVP, may be a useful clinical index to predict fluid responsiveness.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  E/e’ ratio; diastolic function; fluid responsiveness; peripheral venous pressure

Mesh:

Year:  2019        PMID: 30738752     DOI: 10.1053/j.jvca.2019.01.007

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  1 in total

1.  Combination of Static Echocardiographic Indices for the Prediction of Fluid Responsiveness in Patients Undergoing Coronary Surgery: A Pilot Study.

Authors:  Hye-Bin Kim; Sarah Soh; Jong-Wook Song; Min-Yu Kim; Young-Lan Kwak; Jae-Kwang Shim
Journal:  J Clin Med       Date:  2021-04-27       Impact factor: 4.241

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.