Literature DB >> 21724182

Simple weight-based contrast dosing for standardization of portal phase CT liver enhancement.

M Benbow1, R K Bull.   

Abstract

AIM: To investigate the use of a weight-based volume of contrast media to optimize portal enhancement in patients undergoing abdominal computed tomography (CT).
MATERIALS AND METHODS: Thirty-one patients were assessed to establish whether a relationship existed between their weight and the portal liver enhancement achieved. Three methods of estimating weight were evaluated to establish which was the most appropriate to use in clinical practice. One hundred patients were then examined using 100 ml contrast media and 100 further patients using a weight-based contrast volume as dictated by a look-up table. The enhancement achieved by each technique was assessed.
RESULTS: A good correlation was shown between patient weight and contrast enhancement when a fixed volume of contrast media was used (r=-0.825, p<0.0001). Asking the patient was shown to be the most appropriate method for estimating their weight. The mean portal liver enhancement using the fixed dose and weight-adjusted dose were 110 HU (SD=25.1) and 108 HU (SD=11.9), respectively. Weight-adjusted dose brought 37% more patients into the "ideal" enhancement range of 100-125 HU.
CONCLUSION: The use of a simple, practical, weight-based look-up table to decide contrast media volumes during portal phase liver CT can greatly reduce inter-patient variability compared to a fixed-volume technique.
Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21724182     DOI: 10.1016/j.crad.2010.12.022

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Prospective multicenter study on personalized and optimized MDCT contrast protocols: results on liver enhancement.

Authors:  F Zanca; H G Brat; P Pujadas; D Racine; B Dufour; D Fournier; B Rizk
Journal:  Eur Radiol       Date:  2021-04-29       Impact factor: 5.315

2.  Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols.

Authors:  Damiano Caruso; Elisa Rosati; Nicola Panvini; Marco Rengo; Davide Bellini; Giulia Moltoni; Benedetta Bracci; Elena Lucertini; Marta Zerunian; Michela Polici; Domenico De Santis; Elsa Iannicelli; Paolo Anibaldi; Iacopo Carbone; Andrea Laghi
Journal:  Insights Imaging       Date:  2021-03-20

3.  Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis.

Authors:  Daan J de Jong; Véronique V van Cooten; Wouter B Veldhuis; Pim A de Jong; Madeleine Kok
Journal:  Diagnostics (Basel)       Date:  2022-06-25
  3 in total