Literature DB >> 33891176

Ultrasensitive DNA methyltransferase activity sensing and inhibitor evaluation with highly photostable upconversion nanoparticle transducer.

Mingmin Wu1, Mengtian Zhang2, Zhiwei Fan3, Xinyue Qin1, Xiaoxia Zhu1, Haiwei Ji1, Yuling Qin1, Qi Wang4, Li Wu5.   

Abstract

Sensitive and accurate detection of DNA methyltransferase (MTase) is conducive to the understanding of the fundamental biological processes related to DNA methylation, clinical disease diagnosis, and drug discovery. Herein, a new fluorescence transducer based on Förster resonance energy transfer (FRET) between the donor upconversion nanoparticles (UCNPs) and the efficient acceptor gold nanorods (AuNRs) for MTase activity analysis and its inhibitor screening is presented. A double-strand DNA linker between UCNPs and AuNRs could be digested by restriction endonuclease HhaI, preventing the FRET process and recovering the upconversion luminescence (UCL) intensity. With the treatment of MTase, the cutting site was disturbed by the methylation of cytosine, blocking the enzyme digestion. The transducer presented here showed an excellent analytical performance toward MTase M.HhaI in the concentration range 0.08~24 U mL-1 with a detection limit of 0.057 U mL-1 calculated according to the UCL intensity changes at 656 nm excited by 980 nm CW laser, which is superior to most of the reported methods. Furthermore, the as-fabricated transducer also demonstrated high testing and screening capability toward enzyme inhibitors' evaluation. The method takes the advantage of low background fluorescence of UCNPs to improve the accuracy of the measurement, which can be developed as a general strategy for the analysis of various disease-related methyltransferase activity and their corresponding inhibitors, offering a promising strategy for high-performance diagnosis, high-efficient drug exploitation, and treatment effectiveness evaluation.

Entities:  

Keywords:  DNA methyltransferase activity; FRET transducer; Gold nanorod; Methyltransferase inhibitor; Restriction endonuclease; Upconversion nanoparticle

Mesh:

Year:  2021        PMID: 33891176     DOI: 10.1007/s00604-021-04831-z

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  21 in total

1.  A genomic sequencing protocol that yields a positive display of 5-methylcytosine residues in individual DNA strands.

Authors:  M Frommer; L E McDonald; D S Millar; C M Collis; F Watt; G W Grigg; P L Molloy; C L Paul
Journal:  Proc Natl Acad Sci U S A       Date:  1992-03-01       Impact factor: 11.205

Review 2.  DNA methylation: roles in mammalian development.

Authors:  Zachary D Smith; Alexander Meissner
Journal:  Nat Rev Genet       Date:  2013-02-12       Impact factor: 53.242

3.  Single-Molecule Fluorescence Imaging for Ultrasensitive DNA Methyltransferase Activity Measurement and Inhibitor Screening.

Authors:  Hongding Zhang; Kun Zhang; Yuanyuan Yao; Yujie Liu; Ji Ji; Xuedong Huang; Jianwei Liu; Baohong Liu
Journal:  Anal Chem       Date:  2019-07-22       Impact factor: 6.986

4.  Collapse of DNA Tetrahedron Nanostructure for "Off-On" Fluorescence Detection of DNA Methyltransferase Activity.

Authors:  Xiaoyan Zhou; Min Zhao; Xiaolei Duan; Bin Guo; Wei Cheng; Shijia Ding; Huangxian Ju
Journal:  ACS Appl Mater Interfaces       Date:  2017-11-13       Impact factor: 9.229

5.  FRET in a Polymeric Nanocarrier: IR-780 and IR-780-PDMS.

Authors:  Marc P Wolf; Kegang Liu; Thomas F W Horn; Patrick Hunziker
Journal:  Biomacromolecules       Date:  2019-10-18       Impact factor: 6.988

6.  Dual-Amplification Strategy-Based SERS Chip for Sensitive and Reproducible Detection of DNA Methyltransferase Activity in Human Serum.

Authors:  Runzhi Chen; Huayi Shi; Xinyu Meng; Yuanyuan Su; Houyu Wang; Yao He
Journal:  Anal Chem       Date:  2019-02-15       Impact factor: 6.986

7.  Electrochemical assay for the signal-on detection of human DNA methyltransferase activity.

Authors:  Natalie B Muren; Jacqueline K Barton
Journal:  J Am Chem Soc       Date:  2013-11-06       Impact factor: 15.419

8.  Validation of a high-performance liquid chromatography method for thiopurine S-methyltransferase activity in whole blood using 6-mercaptopurine as substrate.

Authors:  Hannah Rieger; Patrik Schmidt; Elke Schaeffeler; Manabu Abe; Mira Schiffhauer; Matthias Schwab; Nicolas von Ahsen; Gabriela Zurek; Hartmut Kirchherr; Maria Shipkova; Eberhard Wieland
Journal:  Clin Chem Lab Med       Date:  2018-04-25       Impact factor: 3.694

9.  Microarray-based resonance light scattering assay for detecting DNA methylation and human DNA methyltransferase simultaneously with high sensitivity.

Authors:  Lan Ma; Min Su; Tao Li; Zhenxin Wang
Journal:  Analyst       Date:  2014-07-21       Impact factor: 4.616

10.  An integrated-molecular-beacon based multiple exponential strand displacement amplification strategy for ultrasensitive detection of DNA methyltransferase activity.

Authors:  Yun-Xi Cui; Xue-Nan Feng; Ya-Xin Wang; Hui-Yu Pan; Hua Pan; De-Ming Kong
Journal:  Chem Sci       Date:  2018-12-20       Impact factor: 9.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.