Literature DB >> 3383504

Severe spondylolisthesis. Reduction and internal fixation.

W T Dick1, B Schnebel.   

Abstract

The authors have developed and algorithm for management of spondylolysis and spondylolisthesis. Since March 1983, 15 patients with an average age of 20 years and with greater than 50% anterior displacement have been treated. The mean follow-up period is 24 months. Before surgery the average anterior displacement was 72%, the average delta angle at L5-S1 representing kyphosis was 73 degrees, and the average lumbar lordosis from L1 to L5 was 64 degrees. An anterior release and fusion was combined with a posterior reduction and instrumentation using the internal fixator. Correction of the anterior displacement averaged 46%, while the kyphosis was corrected a mean of 20 degrees and the lordosis a mean of 12 degrees. The L4 segment was preserved in 13 cases and the L4-L5 angle was improved by a mean of 7 degrees. Postoperative pain and function were improved in all cases. Neurologic complications occurred in four patients, three permanent and one temporary. Hardware failure occurred in two patients, and reoperation has been required in one. Further follow-up evaluation of this technique is required.

Entities:  

Mesh:

Year:  1988        PMID: 3383504

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Comment on topographic relations of neural and ligamentous structures of the lumbosacral junction: in vitro investigation. Spondylolisthesis--no reduction, partial reduction or total reduction?

Authors:  R C Mulholland
Journal:  Eur Spine J       Date:  2001-04       Impact factor: 3.134

2.  Surface electrodes are not sufficient to detect neurotonic discharges: observations in a porcine model and clinical review of deltoid electromyographic monitoring using multiple electrodes.

Authors:  Stanley A Skinner; Ensor E Transfeldt; Kay Savik
Journal:  J Clin Monit Comput       Date:  2008-03-12       Impact factor: 2.502

3.  Single segment of posterior lumbar interbody fusion for adult isthmic spondylolisthesis: reduction or fusion in situ.

Authors:  Xiao-Feng Lian; Tie-Sheng Hou; Jian-Guang Xu; Bing-Fang Zeng; Jie Zhao; Xiao-Kang Liu; Er-Zhu Yang; Cheng Zhao
Journal:  Eur Spine J       Date:  2013-06-14       Impact factor: 3.134

4.  Outcome of L5 radiculopathy after reduction and instrumented transforaminal lumbar interbody fusion of high-grade L5-S1 isthmic spondylolisthesis and the role of intraoperative neurophysiological monitoring.

Authors:  Ralph T Schär; Martin Sutter; Anne F Mannion; Andreas Eggspühler; Dezsö Jeszenszky; Tamas F Fekete; Frank Kleinstück; Daniel Haschtmann
Journal:  Eur Spine J       Date:  2017-01-31       Impact factor: 3.134

Review 5.  Pedicle screw fixation in spinal disorders: a European view.

Authors:  N Boos; J K Webb
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

6.  High-Grade Spondylolisthesis in Adults: Current Concepts in Evaluation and Management.

Authors:  Kyle N Kunze; Daniel T Lilly; Jannat M Khan; Philip K Louie; Joseph Ferguson; Bryce A Basques; Michael T Nolte; Christopher J Dewald
Journal:  Int J Spine Surg       Date:  2020-06-30

7.  Novel concepts in the evaluation and treatment of high-dysplastic spondylolisthesis.

Authors:  Claudio Lamartina; Joseph M Zavatsky; Maria Petruzzi; Nicola Specchia
Journal:  Eur Spine J       Date:  2009-04-28       Impact factor: 3.134

8.  Assessing the Intraoperative Accuracy of Pedicle Screw Placement by Using a Bone-Mounted Miniature Robot System through Secondary Registration.

Authors:  Keng-Liang Kuo; Yu-Feng Su; Chieh-Hsin Wu; Cheng-Yu Tsai; Chih-Hui Chang; Chih-Lung Lin; Tai-Hsin Tsai
Journal:  PLoS One       Date:  2016-04-07       Impact factor: 3.240

9.  A ball-slide-type interbody distractor is effective in posterior reduction and internal fixation for patients with mid- to high-grade isthmic spondylolisthesis enrolled in a randomized clinical trial.

Authors:  Pengfei Li; Zongmao Zhao; Nan Jia; Litao Wang; Zhaosheng Sun; Xianhui Jin
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.