Literature DB >> 3381657

Implant fixation improved by close fit. Cylindrical implant-bone interface studied in rabbits.

L Carlsson1, T Röstlund, B Albrektsson, T Albrektsson.   

Abstract

Cylindric titanium implants of three different diameters were inserted and stabilized in a 3.7-mm burr hole in the rabbit tibia. The purpose of the study was to investigate the interfacial reaction to screw- and cylinder-shaped implants, and to determine if there is a critical gap at the insertion between bone and implant that prevents direct cortical bone apposition on the implant. The study indicated that this critical gap approached zero.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3381657     DOI: 10.3109/17453678809149361

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  18 in total

1.  The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty.

Authors:  Li-dong Wu; H J Hahne; J Hassenpflug
Journal:  J Zhejiang Univ Sci       Date:  2004-10

2.  Tissue reactions to polyethylene implants with different surface topography.

Authors:  A Rosengren; L M Bjursten; N Danielsen; H Persson; M Kober
Journal:  J Mater Sci Mater Med       Date:  1999-02       Impact factor: 3.896

3.  Minimally invasive 3D data registration in computer and robot assisted total knee arthroplasty.

Authors:  P F La Palombara; M Fadda; S Martelli; M Marcacci
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

Review 4.  Implant surface characteristics and their effect on osseointegration.

Authors:  A Barfeie; J Wilson; J Rees
Journal:  Br Dent J       Date:  2015-03-13       Impact factor: 1.626

5.  Deproteinized bovine bone derived with collagen improves soft and bone tissue outcomes in flapless immediate implant approach and immediate provisionalization: a randomized clinical trial.

Authors:  Felipe Fonseca Girlanda; Hsu Shao Feng; Mônica Grazieli Corrêa; Márcio Zaffalon Casati; Suzana Peres Pimentel; Fernanda Vieira Ribeiro; Fabiano Ribeiro Cirano
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

6.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

7.  Does sodium fluoride in bone cement affect implant fixation? Part I: bone tissue response, implant fixation and histology in nine rabbits.

Authors:  Mikael Sundfeldt; Michael Widmark; Ann Wennerberg; Johan Kärrholm; Carina B Johansson; Lars V Carlsson
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

8.  Microscopic analysis of autograft bone applied at the interface of porous-coated devices in human cancellous bone.

Authors:  A A Hofmann; R D Bloebaum; M H Rubman; K N Bachus; R L Plaster
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

9.  A histomorphometric study on collagen-apatite composite as a graft material: the influence of gap size at the titanium-bone interface in animal model.

Authors:  Sung-Soo Shin; Jun Woo Park; Hyun-Man Kim; Jea Seung Ko; Pil-Young Yun
Journal:  J Mater Sci Mater Med       Date:  2009-04-04       Impact factor: 3.896

10.  A new classification of peri implant gaps based on gap location (A case series of 210 immediate implants).

Authors:  Douglas Deporter; Ali Akbar Khoshkhounejad; Nikfam Khoshkhounejad; Mohammad Ketabi
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06
View more