Abstract
Glycated hemoglobin (HbA1c) is a product of the spontaneous reaction between hemoglobin and elevated glucose levels in the blood. It is included among the so-called advanced glycation end products, of which is the most important for the clinical diagnosis of diabetes mellitus, and it can serve as an alternative to glycemia measurement. Compared to the diagnosis of diabetes mellitus by glycemia, the HbA1c level is less influenced by a short-term problem with diabetes compensation. Mass spectroscopy and chromatographic techniques are among the standard methods of HbA1c level measurement. Compared to glycemia measurement, there is lack of simple methods for diabetes mellitus diagnosis by means of the HbA1c assay using a point-of-care test. This review article is focused on the surveying of facts about HbA1c and its importance in diabetes mellitus diagnosis, and surveying standard methods and new methods suitable for the HbA1c assay under point-of-care conditions. Various bioassays and biosensors are mentioned and their specifications are discussed.Entities:
Keywords: advanced glycation end products; analysis; bioanalysis; biosensor; chromatography; diabetes; diagnosis; glucose; hand held assay; lateral flow test; mass spectrometry
Mesh:
Substances:
Year: 2021 PMID: 33806493 PMCID: PMC8000313 DOI: 10.3390/bios11030070
Source DB: PubMed Journal: Biosensors (Basel) ISSN: 2079-6374
Figure 1Chemical principles of hemoglobin glycation, Hb = hemoglobin.
Basic specifications of non-glycated hemoglobin and HbA1c.
| Specification | Non-Glycated Hemoglobin | HbA1c | References |
|---|---|---|---|
| Number of glycated sites/molecular weight | 1/64.5 kDa | 15/68 kDa | [ |
| Florescence intensity | 34% | 45% | [ |
| Hydrophobicity | high | low | [ |
| Percentage in blood of health people | above 94% | under 6.0% | [ |
| Percentage in blood of people with prediabetes | 94.0–93.5% | 6.0–6.5% | [ |
| Percentage in blood of people with diabetes mellitus | under 93.5% | above 6.5% | [ |
Figure 2General principle of HbA1c assay in the presence of standard hemoglobin.
Figure 3General principle of lateral flow test for HbA1c assay.
Biosensors and bioassays for HbA1c measurement.
| Principle of Assay | Recognition Parts in the Assay | Specifications | Limit of Detection | References |
|---|---|---|---|---|
| Surface plasmon resonance | aptamer | sensitivity 1.06 × 10−3 RU/nmol/L | limit of detection 2.55 nmol/L | [ |
| Surface plasmon resonance | aptamer | linear dynamic range 18–147 nmol/L | limit of detection 1 nmol/L | [ |
| Measuring of photocurrent using bacteriorhodopsin and aptamer embedded membrane, interaction with analyte causes reduction of photocurrent | aptamer | dynamic range 0.1–100 μg/mL in a 15 min measuring cycle | limit of detection under 0.1 μg/mL | [ |
| Quenching of ruthenium complex containing nanoparticles electrochemiluminescence in the presence of HbA1c | aptamer | linear range 0.1–18.5% | limit of detection 0.015% HbA1c from the total hemoglobin | [ |
| Enzyme catalyzed oxidation of fructosyl valyl histidine as a mimetic of HbA1c, amperometric detection followed | fructosyl peptide oxidase | calibration range 0.1 to 2 mmol/L | limit of detection 0.3 μmol/L | [ |
| Quartz crystal microbalance biosensor with immobilized antibody directly interacted with HbA1c, drop in oscillation frequency followed | polyclonal antibody | - | limit of detection 0.045 mg/mL | [ |
| Voltametric biosensor with immobilized aptamer, interaction with HbA1c caused change in sensitivity to Prussian blue in ambient solution | aptamer | linear range 1 nmol/L–13.8 μmol/L, sensitivity 269 μA/cm2 | limit of detection 1 nmol/L | [ |
| HbA1c was caught by boronic acid and then catalyzed reduction of hydrogen peroxide, which was recorded by cyclic voltammetry | gold nanoparticles covered with 4-mercaptophenylboronic acid | linear dynamic range 5–1000 μg/mL respective 2–20%, assay lasting 65 min | - | [ |
| Interaction of non-glycated hemoglobin respective to HbA1c with molecularly imprinted polymer caused change in voltametric characteristics | molecularly imprinted polymer based on boronic acid | - | limit of detection equal 0.08 ng/mL for the non-glycated hemoglobin, 0.09 ng/mL for the HbA1c | [ |