Literature DB >> 28365286

Detection of glycated hemoglobin with voltammetric sensing amplified by 3D-structured nanocomposites.

Utkarsh Jain1, Shaivya Gupta1, Nidhi Chauhan2.   

Abstract

Glycated hemoglobin (HbA1c), a marker for glycine level in blood, while detecting over a long period of time (up to 2-3 months) shows consistency. Therefore, HbA1c has been mostly used and indeed an established test for monitoring the glycemic control in persons suffering from diabetes. 3D-structured reduced graphene oxide (rGO), multiwalled carbon nanotubes (MWCNT) and platinum nanoparticles (PtNPs) composite (PtNPs/rGO-MWCNT) were synthesized and used as interface for the development of an electrochemical HbA1c biosensor. The network structure of rGO-MWCNT nanocomposite provides more active sites for Pt deposition and the synergistic effect of rGO, MWCNTs and PtNPs significantly improved the electrochemical performance of the working electrode. The structure of PtNPs/rGO-MWCNT nanocomposite was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance study (EIS). This biosensor exhibited a response time of less than 3s, a wide linear concentration range of 0.05-1000μM with detection limit of 0.1μM, good repeatability and satisfactory reproducibility. The biosensor retained 50% of its initial response after 12 weeks at 25°C. The proposed biosensor was successfully applied for the determination of HbA1c concentration in human blood samples with recoveries between 93.7 and 98.3%.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fructosyl valine oxidase; Glycated hemoglobin; Graphene oxide (rGO); Multiwalled carbon nanotubes (MWCNT) and platinum nanoparticles

Mesh:

Substances:

Year:  2017        PMID: 28365286     DOI: 10.1016/j.ijbiomac.2017.03.127

Source DB:  PubMed          Journal:  Int J Biol Macromol        ISSN: 0141-8130            Impact factor:   6.953


  5 in total

1.  Enzyme-based sensing on nanohybrid film coated over FTO electrode for highly sensitive detection of antibiotics.

Authors:  Nidhi Chauhan; Sapna Balayan; Shaivya Gupta; Jaskaran Singh; Utkarsh Jain
Journal:  Bioprocess Biosyst Eng       Date:  2021-08-12       Impact factor: 3.210

Review 2.  A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.

Authors:  Zhikun Zhan; Yang Li; Yuliang Zhao; Hongyu Zhang; Zhen Wang; Boya Fu; Wen Jung Li
Journal:  Biosensors (Basel)       Date:  2022-04-08

3.  Nanohybrid-based immunosensor prepared for Helicobacter pylori BabA antigen detection through immobilized antibody assembly with @ Pdnano/rGO/PEDOT sensing platform.

Authors:  Shaivya Gupta; Utkarsh Jain; Bayu Tri Murti; Athika Darumas Putri; Ashutosh Tiwari; Nidhi Chauhan
Journal:  Sci Rep       Date:  2020-12-04       Impact factor: 4.379

4.  Tungsten Disulfide Decorated Screen-Printed Electrodes for Sensing of Glycated Hemoglobin.

Authors:  Sunil Kumar Mahobiya; Sapna Balayan; Nidhi Chauhan; Manika Khanuja; Naresh K Kuchhal; S S Islam; Utkarsh Jain
Journal:  ACS Omega       Date:  2022-09-14

5.  Glycated Hemoglobin and Methods for Its Point of Care Testing.

Authors:  Miroslav Pohanka
Journal:  Biosensors (Basel)       Date:  2021-03-04
  5 in total