Literature DB >> 31622711

An amperometric biosensor for specific detection of glycated hemoglobin based on recombinant engineered fructosyl peptide oxidase.

Hamid Shahbazmohammadi1, Soroush Sardari2, Eskandar Omidinia3.   

Abstract

Here, we present a specific biosensor based on the detection of glycated hemoglobin (HbA1c) proteolytic digestion product, fructosyl valyl histidine (Fru-ValHis). A recombinant engineered fructosyl peptide oxidase (FPOX) enzyme with improved specificity was immobilized on the electrode surface modified by chitosan (CHIT), graphene oxide (GO) and gold nanoparticles (AuNPs). The biosensor exhibited a linear response toward different concentrations of Fru-ValHis ranging from 0.1 to 2 mM with a sensitivity of 8.45 µA mM-1 cm-2. Detection limit of the current biosensor for Fru-ValHis was 0.3 µM as the lowest quantity required giving a signal to a background. Analytical recovery of added Fru-ValHis in whole blood was 95.1-98.35% for FPOX/AuNPs/GO/CHIT/FTO electrode. For Fru-ValHis determination by FPOX-AuNPs-GO-CHIT/FTO electrode, within-run coefficient of variation (CV) was between 1.3% and 2.4% and between run CV was between 2.1% and 3.5%. A significant change in electron transfer resistance after the incubation of FPOX-modified electrode with Fru-ValHis was observed, while no response was achieved with control, indicating specific measurement of Fru-ValHis. Moreover, designed biosensor measured HbA1c in human blood samples and the results were well agreed with that obtained with NORUDIA™ N HbA1c diagnostic kit. Overall, suitable specificity of the engineered FPOX made the bioelectrode responded well to the Fru-ValHis level, which demonstrates a promising application for specific detection of HbA1c biomarker.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Diabetes; Fructosyl peptide oxidase (FPOX); Glycated hemoglobin (HbA1c)

Mesh:

Substances:

Year:  2019        PMID: 31622711     DOI: 10.1016/j.ijbiomac.2019.10.025

Source DB:  PubMed          Journal:  Int J Biol Macromol        ISSN: 0141-8130            Impact factor:   6.953


  4 in total

Review 1.  A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.

Authors:  Zhikun Zhan; Yang Li; Yuliang Zhao; Hongyu Zhang; Zhen Wang; Boya Fu; Wen Jung Li
Journal:  Biosensors (Basel)       Date:  2022-04-08

2.  Tungsten Disulfide Decorated Screen-Printed Electrodes for Sensing of Glycated Hemoglobin.

Authors:  Sunil Kumar Mahobiya; Sapna Balayan; Nidhi Chauhan; Manika Khanuja; Naresh K Kuchhal; S S Islam; Utkarsh Jain
Journal:  ACS Omega       Date:  2022-09-14

3.  Glycated Hemoglobin and Methods for Its Point of Care Testing.

Authors:  Miroslav Pohanka
Journal:  Biosensors (Basel)       Date:  2021-03-04

Review 4.  Biomedical applications of chitosan-graphene oxide nanocomposites.

Authors:  Wenjun Feng; Zhengke Wang
Journal:  iScience       Date:  2021-12-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.