Literature DB >> 33806324

Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmission.

Alberto Encarnación-Martínez1, Pedro Pérez-Soriano1, Roberto Sanchis-Sanchis1,2, Antonio García-Gallart3, Rafael Berenguer-Vidal4.   

Abstract

Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two separate days over the instrumented treadmill (AccTrea) and simultaneously with an acceleration impact system attached to the participant (AccAthl). AccTrea was demonstrated to be a valid and reliable tool for measuring spatio-temporal parameters like step length (validity intraclass correlation coefficient (ICC) = 0.94; reliability ICC = 0.92), step time (validity ICC = 0.95; reliability ICC = 0.96), and step frequency (validity ICC = 0.95; reliability ICC = 0.96) during running. Peak acceleration impact variables showed a high reliability for the left (reliability ICC = 0.88) and right leg (reliability ICC = 0.85), and peak impact asymmetry showed a modest validity (ICC = 0.55). These results indicated that the AccTrea system is a valid and reliable way to assess spatio-temporal variables, and a reliable tool for measuring acceleration impacts during running.

Entities:  

Keywords:  impact acceleration; instrumented treadmill; retraining; running; spatio-temporal

Mesh:

Year:  2021        PMID: 33806324      PMCID: PMC7961446          DOI: 10.3390/s21051758

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  42 in total

Review 1.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

2.  Kinematics and electromyography of lower limb muscles in overground and treadmill running.

Authors:  V Wank; U Frick; D Schmidtbleicher
Journal:  Int J Sports Med       Date:  1998-10       Impact factor: 3.118

3.  Evaluating dynamic error of a treadmill and the effect on measured kinetic gait parameters: Implications and possible solutions.

Authors:  Alessandro Garofolini; Simon Taylor; Julien Lepine
Journal:  J Biomech       Date:  2018-10-27       Impact factor: 2.712

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Long-term efficacy of conditioning training program combined with feedback on kinetics and kinematics in male runners.

Authors:  Amir Letafatkar; Pouya Rabiei; Niloufar Farivar; Gelareh Alamouti
Journal:  Scand J Med Sci Sports       Date:  2019-12-02       Impact factor: 4.221

6.  Are overground or treadmill runners more likely to sustain tibial stress fracture?

Authors:  C Milgrom; A Finestone; S Segev; C Olin; T Arndt; I Ekenman
Journal:  Br J Sports Med       Date:  2003-04       Impact factor: 13.800

7.  Psychophysical bases of perceived exertion.

Authors:  G A Borg
Journal:  Med Sci Sports Exerc       Date:  1982       Impact factor: 5.411

Review 8.  Injuries in runners; a systematic review on risk factors and sex differences.

Authors:  Maarten P van der Worp; Dominique S M ten Haaf; Robert van Cingel; Anton de Wijer; Maria W G Nijhuis-van der Sanden; J Bart Staal
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

9.  BLESeis: Low-Cost IoT Sensor for Smart Earthquake Detection and Notification.

Authors:  Jongbin Won; Junyoung Park; Jong-Woong Park; Inho Kim
Journal:  Sensors (Basel)       Date:  2020-05-23       Impact factor: 3.576

10.  Train-Induced Vibration Monitoring of Track Slab under Long-Term Temperature Load Using Fiber-Optic Accelerometers.

Authors:  Jianxiang Zhang; Wenzhu Huang; Wentao Zhang; Fang Li; Yanliang Du
Journal:  Sensors (Basel)       Date:  2021-01-25       Impact factor: 3.576

View more
  3 in total

1.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

2.  Validity and Reliability of the Leomo Motion-Tracking Device Based on Inertial Measurement Unit with an Optoelectronic Camera System for Cycling Pedaling Evaluation.

Authors:  José Manuel Plaza-Bravo; Manuel Mateo-March; Roberto Sanchis-Sanchis; Pedro Pérez-Soriano; Mikel Zabala; Alberto Encarnación-Martínez
Journal:  Int J Environ Res Public Health       Date:  2022-07-08       Impact factor: 4.614

Review 3.  Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis.

Authors:  Lauren C Benson; Anu M Räisänen; Christian A Clermont; Reed Ferber
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  3 in total