Literature DB >> 33797595

Technical safety and efficacy of a blunt-tip microwave ablation electrode for CT-guided ablation of pulmonary ground-glass opacity nodules.

Jiachang Chi1, Zhi Wang2, Min Ding2, Hao Hu2, Bo Zhai3.   

Abstract

OBJECTIVES: To evaluate the safety and technical efficacy of a customized blunt-tip microwave ablation (MWA) electrode for CT-guided ablation of pulmonary ground-glass opacity nodules (GGOs).
MATERIALS AND METHODS: This was a retrospective before-after study. All consented patients with GGOs who underwent MWA treatment using conventional sharp-tip electrodes (group A) between January 2018 and December 2018 or new blunt-tip electrodes (group B) between January 2019 and December 2019 in our institution were included. The individual features of each patient and lesion, as well as technical and clinical information, were collected and analyzed.
RESULTS: Sixteen (7 males, 9 females; mean age, 64.9 ± 12.3 years) and twenty-six (11 males, 15 females; mean age, 66.5 ± 10.7 years) patients were enrolled in groups A and B, respectively. The technique was successfully performed in all patients and a follow-up CT scan at 24 h after MWA showed that the technical efficacy rate was 100% in both groups. Twelve (75.0%) grade I complications were noted in group A, whereas 11 (42.3%) were noted in group B (p = 0.039, chi-square test). No bleeding occurred within the lesions in group B.
CONCLUSIONS: The blunt-tip MWA electrode is a safe and technically effective tool for ablating GGO lesions. KEY POINTS: • A new blunt-tip MWA electrode was used for CT-guided ablation of GGO lesions. • The blunt-tip MWA electrode could improve the safety of GGO ablation. • The technical efficacy of ablation was maintained by using the blunt-tip MWA electrode.

Entities:  

Keywords:  Ablation techniques; Lung neoplasms; Safety

Year:  2021        PMID: 33797595     DOI: 10.1007/s00330-021-07774-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Society of Interventional Radiology clinical practice guidelines.

Authors:  David Sacks; Tricia E McClenny; John F Cardella; Curtis A Lewis
Journal:  J Vasc Interv Radiol       Date:  2003-09       Impact factor: 3.464

2.  Diagnostic and therapeutic lumbar puncture performed safely and efficiently with a thin blunt needle.

Authors:  Anders Møller; Arash Afshari; Ole Weis Bjerrum
Journal:  Dan Med J       Date:  2013-09       Impact factor: 1.240

3.  Performance of a New Blunt-Tip Coaxial Needle for Percutaneous Biopsy and Drainage of "Hard-To-Reach" Targets.

Authors:  Roberto Luigi Cazzato; Julien Garnon; Behnam Shaygi; Jean Caudrelier; Salem Bauones; Georgia Tsoumakidou; Guillaume Koch; Afshin Gangi
Journal:  Cardiovasc Intervent Radiol       Date:  2017-05-03       Impact factor: 2.740

4.  The blunt needle: a new percutaneous access device.

Authors:  E W Akins; I F Hawkins; C Mladinich; R Tupler; R J Siragusa; R Pry
Journal:  AJR Am J Roentgenol       Date:  1989-01       Impact factor: 3.959

5.  Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017.

Authors:  Heber MacMahon; David P Naidich; Jin Mo Goo; Kyung Soo Lee; Ann N C Leung; John R Mayo; Atul C Mehta; Yoshiharu Ohno; Charles A Powell; Mathias Prokop; Geoffrey D Rubin; Cornelia M Schaefer-Prokop; William D Travis; Paul E Van Schil; Alexander A Bankier
Journal:  Radiology       Date:  2017-02-23       Impact factor: 11.105

6.  Transvenous transjugular renal core biopsy with a redesigned biopsy set including a blunt-tipped needle.

Authors:  Constantinos T Sofocleous; Philip Bahramipour; Christopher Mele; Clay R Hinrichs; Alison Barone; Hani Abujudeh
Journal:  Cardiovasc Intervent Radiol       Date:  2002-02-19       Impact factor: 2.740

7.  A feasibility and safety study of computed tomography-guided percutaneous microwave ablation: a novel therapy for multiple synchronous ground-glass opacities of the lung.

Authors:  Guanghui Huang; Xia Yang; Wenhong Li; Jiao Wang; Xiaoying Han; Zhigang Wei; Min Meng; Yang Ni; Zhigeng Zou; Qiang Wen; Jianjian Dai; Tiehong Zhang; Xin Ye
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

8.  Radiofrequency ablation for ground-glass opacity-dominant lung adenocarcinoma.

Authors:  Hiroshi Kodama; Koichiro Yamakado; Takaaki Hasegawa; Motoshi Takao; Osamu Taguchi; Ichiro Fukai; Hajime Sakuma
Journal:  J Vasc Interv Radiol       Date:  2014-03       Impact factor: 3.464

Review 9.  Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology.

Authors:  Douglas E Wood; Ella A Kazerooni; Scott L Baum; George A Eapen; David S Ettinger; Lifang Hou; David M Jackman; Donald Klippenstein; Rohit Kumar; Rudy P Lackner; Lorriana E Leard; Inga T Lennes; Ann N C Leung; Samir S Makani; Pierre P Massion; Peter Mazzone; Robert E Merritt; Bryan F Meyers; David E Midthun; Sudhakar Pipavath; Christie Pratt; Chakravarthy Reddy; Mary E Reid; Arnold J Rotter; Peter B Sachs; Matthew B Schabath; Mark L Schiebler; Betty C Tong; William D Travis; Benjamin Wei; Stephen C Yang; Kristina M Gregory; Miranda Hughes
Journal:  J Natl Compr Canc Netw       Date:  2018-04       Impact factor: 11.908

10.  Computed tomography-guided percutaneous microwave ablation for treatment of peripheral ground-glass opacity-Lung adenocarcinoma: A pilot study.

Authors:  Xia Yang; Xin Ye; Zhengyu Lin; Yong Jin; Kaixian Zhang; Yuting Dong; Guohua Yu; Haipeng Ren; Weijun Fan; Jin Chen; Qingfeng Lin; Guanghui Huang; Zhigang Wei; Yang Ni; Wenhong Li; Xiaoying Han; Min Meng; Jiao Wang; Yuliang Li
Journal:  J Cancer Res Ther       Date:  2018       Impact factor: 1.805

View more
  1 in total

1.  Computed tomography-guided microwave ablation for non-small cell lung cancer patients on antithrombotic therapy: a retrospective cohort study.

Authors:  Sheng Xu; Zhi-Xin Bie; Yuan-Ming Li; Bin Li; Jin-Zhao Peng; Fan-Lei Kong; Xiao-Guang Li
Journal:  Quant Imaging Med Surg       Date:  2022-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.