Literature DB >> 33791044

A Novel Method for Accurate Quantification of Split Glomerular Filtration Rate Using Combination of Tc-99m-DTPA Renal Dynamic Imaging and Its Plasma Clearance.

Xiaoxi Pang1, Fei Li1, Shan Huang1, Cheng'en Wang2, Tao Zhang1, Zihao Hu1, Hao Cheng1, Xinchen Tao1, Wenrui Chang1.   

Abstract

PURPOSE: To precisely quantify split glomerular filtration rate by Tc-99m-DTPA renal dynamic imaging and plasma clearance in order to increase its consistency among doctors.
METHODS: Tc-99m-DTPA renal dynamic imaging was performed according to the conventional radionuclide renal dynamic imaging by five double-blinded doctors independently and automatically calculated split GFR, namely, gGFR. Moreover, the conventional radionuclide renal dynamic imaging was assessed to only outline the kidney, blank background, and automatically calculated split GFR, gGFR'. The total GFR value of patients, tGFR, was obtained by the double-plasma method. According to the formula, Precise GFR (pGFR) = gGFR'/(gGFR' + gGFR') × tGFR. The precise GFR value of the divided kidney, pGFR, was calculated. The Kendall's W test was used to compare the consistency of gGFR and pGFR drawn by five physicians.
RESULTS: According to Kendall's W consistency test, Kendall's coefficient of concordance was 0.834, p = 0.0001 using conventional method. The same five doctors used blank background again and the same standard Gates method to draw the kidneys, which automatically calculated gGFR'. Using input formula, the pGFR was calculated and Kendall's W consistency test (Kendall's coefficient of concordance = 0.956, p = 0.0001).
CONCLUSION: The combination of Tc-99m-DTPA renal dynamic imaging combined with the double-plasma method could achieve accurate split GFR, and because of the omission of influence factors, the consistency of pGFR obtained by different doctors using this method was significantly higher than that of conventional Tc-99m-DTPA renal dynamic imaging.
Copyright © 2021 Xiaoxi Pang et al.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33791044      PMCID: PMC7984922          DOI: 10.1155/2021/6643586

Source DB:  PubMed          Journal:  Dis Markers        ISSN: 0278-0240            Impact factor:   3.434


  12 in total

1.  Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method.

Authors:  Kazuo Itoh
Journal:  Ann Nucl Med       Date:  2003-10       Impact factor: 2.668

2.  Chronic kidney disease after nephrectomy in patients with renal cortical tumours: a retrospective cohort study.

Authors:  William C Huang; Andrew S Levey; Angel M Serio; Mark Snyder; Andrew J Vickers; Ganesh V Raj; Peter T Scardino; Paul Russo
Journal:  Lancet Oncol       Date:  2006-09       Impact factor: 41.316

3.  [Measurement of glomerular filtration rate with renal dynamic imaging: comparison with two-sample method].

Authors:  Chun-li Zhang; Qian Li; Li Zuo; Ying Cui; Yan-fu Wang; Feng-qin Guo; Guang-yu Zhao; Xu-chu Zhang; Yu-hong Zhou; Rong-fu Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2004-12

4.  THE RENAL CLEARANCE OF ENDOGENOUS "CREATININE" IN MAN.

Authors:  J Brod; J H Sirota
Journal:  J Clin Invest       Date:  1948-09       Impact factor: 14.808

5.  Report of the Radionuclides in Nephrourology Committee on renal clearance.

Authors:  M D Blaufox; M Aurell; B Bubeck; E Fommei; A Piepsz; C Russell; A Taylor; H S Thomsen; D Volterrani
Journal:  J Nucl Med       Date:  1996-11       Impact factor: 10.057

6.  Measurement of glomerular filtration rate with technetium-99m DTPA: comparison of plasma clearance techniques.

Authors:  D G Waller; C M Keast; J S Fleming; D M Ackery
Journal:  J Nucl Med       Date:  1987-03       Impact factor: 10.057

7.  The gamma camera as an absolute measurement device: determination of glomerular filtration rate in 99mTc-DTPA renography using a dual head gamma camera.

Authors:  Ove Carlsen
Journal:  Nucl Med Commun       Date:  2004-10       Impact factor: 1.690

8.  Comparison of methods for determination of glomerular filtration rate: low and high-dose Tc-99m-DTPA renography, predicted creatinine clearance method, and plasma sample method.

Authors:  Majid Assadi; Mohammad Eftekhari; Mehrdad Hozhabrosadati; Mohsen Saghari; Abdolali Ebrahimi; Iraj Nabipour; Mohammad Zaki Abbasi; Darab Moshtaghi; Moloud Abbaszadeh; Sakineh Assadi
Journal:  Int Urol Nephrol       Date:  2008-08-09       Impact factor: 2.370

9.  (99m)Tc-DTPA renal dynamic imaging method may be unsuitable to be used as the reference method in investigating the validity of CDK-EPI equation for determining glomerular filtration rate.

Authors:  Peng Xie; Jian-Min Huang; Xiao-Mei Liu; Wei-Jie Wu; Li-Ping Pan; Hai-Ying Lin
Journal:  PLoS One       Date:  2013-05-01       Impact factor: 3.240

10.  Comparison of glomerular filtration rate estimated by plasma clearance method with modification of diet in renal disease prediction equation and Gates method.

Authors:  N Prasad; S Barai; S Gambhir; D S Parasar; M Ora; A Gupta; R K Sharma
Journal:  Indian J Nephrol       Date:  2012-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.