[Measurement of glomerular filtration rate with renal dynamic imaging: comparison with two-sample method].

Chun-li Zhang1, Qian Li, Li Zuo, Ying Cui, Yan-fu Wang, Feng-qin Guo, Guang-yu Zhao, Xu-chu Zhang, Yu-hong Zhou, Rong-fu Wang.   

Abstract

OBJECTIVE: To compare the estimation of glomerular filtration rate (GFR) by renal dynamic imaging with that estimated by two-sample method and evaluate the reliability of measurement of GFR by renal dynamic imaging.
METHODS: The study was performed in 54 patients (33 males and 21 females; aged 15 to 82 years) with primary or secondary chronic nephrosis. The patients were intravenously bolus injected with 185 MBq /1mL of (99)Tc(m)-DTPA 20 min after drinking 300 mL of water. Renal dynamic imaging was performed and the image was processed according to standard procedure (Gates' method) to obtain GFR. 3 mL of blood was withdrawn 2 h and 4 h postinjection, respectively, and radioactivity of 1mL plasma was measured. GFR was calculated by the formula of two-sample method. The correlation of GFRs measured by renal dynamic imaging and by two-sample method was analyzed using regression analysis. The correlations of GFRs determined by the two methods with urea and creatinine were also measured.
RESULTS: The GFR measured by renal dynamic imaging was slightly lower than that measured by two-sample method. Excellent correlation was obtained by two methods with r= 0.881 5 and P<0.01. The linear regression equation was GFR (renal dynamic imaging method)=0.661 4GFR (two-sample method) +21.89. The related lines of GFRs measured by the two methods with urea or creatinine were similar, which indicated the two methods were similar in identifying the changes in renal function. GFRs measured by the two methods showed good agreement for most of patients except three patients who were too thin or too fat.
CONCLUSION: Generally, GFR obtained by renal dynamic imaging is reliable for identifying the changes in renal function and correlated well with GFR obtained by two-sample method. But great error may be obtained with specific individuals, such as too thin or too fat subjects.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15605093

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  2 in total

1.  Impact of Body Mass Index on Gates Method of Glomerular Filtration Rate Estimation: A Comparative Study with Single Plasma Sample Method.

Authors:  Amit Nautiyal; Anirban Mukherjee; Deepanjan Mitra; Piyali Chatterjee; Anindya Roy
Journal:  Indian J Nucl Med       Date:  2019 Jan-Mar

2.  A Novel Method for Accurate Quantification of Split Glomerular Filtration Rate Using Combination of Tc-99m-DTPA Renal Dynamic Imaging and Its Plasma Clearance.

Authors:  Xiaoxi Pang; Fei Li; Shan Huang; Cheng'en Wang; Tao Zhang; Zihao Hu; Hao Cheng; Xinchen Tao; Wenrui Chang
Journal:  Dis Markers       Date:  2021-03-13       Impact factor: 3.434

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.