Literature DB >> 33788928

Reliability of Three Urine Specific Gravity Meters Measuring Brix and Urine Solutions at Different Temperatures.

Floris Wardenaar1, Carmen P Ortega-Santos1, Kaila Vento1, Stephanie Olzinski1, Jason Olig1, Stavros Kavouras1, Carol Johnston1.   

Abstract

CONTEXT: The measurement of urine specific gravity should be performed at room temperature (20 °C) but sample temperature is not always taken in consideration.
OBJECTIVE: Evaluate the effect of sample temperature on the measurement accuracy of a digital (DIG) and optical (MAN) refractometer and a hydrometer (HYD).
DESIGN: Quantitative comparison between measurement outcomes for a reference solution (sucrose, degrees Brix) and fresh collected urine samples. SAMPLES: Experiment 1 used a 24 Brix (°Bx) samples and experiment 2 used 33 fresh urine samples. MAIN OUTCOME MEASURE: Urine specific gravity (USG).
RESULTS: Experiment 1 showed DIG and MAN did not differ from reference, but HYD reported lower or inconsistent values compared to Bx, while highly correlating with Bx solutions (r: > 0.89). The overall diagnostic ability of elevated USG (≥ 1.020; ≥ 1.025; ≥ 1.030) was high for all tools (AUC > 0.92). Misclassification of samples increased from 0 to 2 at 1.020 to 1 to 3 samples at cutoff 1.025 and 1.030 USG. Bland-Altman analysis showed DIG 5 °C underreports slightly without reporting bias (r: -0.344, P = 0.13); all other plots for DIG, MAN, and HYD showed considerably larger underreporting at higher concentrations (r ranging from -0.21 to -0.97 with P > .02) at all temperatures. The outcomes of experiment 2 using DIG 20°C as standard, showed only negligible differences between DIG and MAN at all temperatures, but larger differences using HYD.
CONCLUSIONS: All tools showed reporting bias when compared to °Bx solutions which can impact classification of low and high urine concentration at higher USG cutoff values, especially at a sample temperature of 37 °C. © by the National Athletic Trainers' Association, Inc.

Entities:  

Keywords:  USG; accuracy; hydration status; validation

Year:  2021        PMID: 33788928      PMCID: PMC8063665          DOI: 10.4085/1062-6050-0142.20

Source DB:  PubMed          Journal:  J Athl Train        ISSN: 1062-6050            Impact factor:   2.860


  26 in total

1.  Comparison of digital and optical hand-held refractometers for the measurement of feline urine specific gravity.

Authors:  Alexander D Bennett; Grace E McKnight; Steve J Dodkin; Kerry E Simpson; Anita M Schwartz; Danièlle A Gunn-Moore
Journal:  J Feline Med Surg       Date:  2010-12-24       Impact factor: 2.015

Review 2.  American College of Sports Medicine position stand. Exercise and fluid replacement.

Authors:  Michael N Sawka; Louise M Burke; E Randy Eichner; Ronald J Maughan; Scott J Montain; Nina S Stachenfeld
Journal:  Med Sci Sports Exerc       Date:  2007-02       Impact factor: 5.411

3.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

4.  Human hydration indices: acute and longitudinal reference values.

Authors:  Lawrence E Armstrong; Amy C Pumerantz; Kelly A Fiala; Melissa W Roti; Stavros A Kavouras; Douglas J Casa; Carl M Maresh
Journal:  Int J Sport Nutr Exerc Metab       Date:  2010-04       Impact factor: 4.599

5.  Assessment of hydration biomarkers including salivary osmolality during passive and active dehydration.

Authors:  C X Muñoz; E C Johnson; J K Demartini; R A Huggins; A L McKenzie; D J Casa; C M Maresh; L E Armstrong
Journal:  Eur J Clin Nutr       Date:  2013-10-16       Impact factor: 4.016

6.  Dehydration and acute weight gain in mixed martial arts fighters before competition.

Authors:  Adam M Jetton; Marcus M Lawrence; Marco Meucci; Tracie L Haines; Scott R Collier; David M Morris; Alan C Utter
Journal:  J Strength Cond Res       Date:  2013-05       Impact factor: 3.775

7.  The Effect of Storing Temperature and Duration on Urinary Hydration Markers.

Authors:  J D Adams; Stavros A Kavouras; Evan C Johnson; Lisa T Jansen; Catalina Capitan-Jimenez; Joseph I Robillard; Andy Mauromoustakos
Journal:  Int J Sport Nutr Exerc Metab       Date:  2016-09-06       Impact factor: 4.599

8.  Effects of drying methods on nitrogen and energy concentrations in pig feces and urine, and poultry excreta.

Authors:  B M Jacobs; J F Patience; W A Dozier; K J Stalder; B J Kerr
Journal:  J Anim Sci       Date:  2011-03-31       Impact factor: 3.159

9.  Agreement of urine specific gravity measurements between manual and digital refractometers.

Authors:  Dawn M Minton; Eric Kyle O'Neal; Toni Marie Torres-McGehee
Journal:  J Athl Train       Date:  2014-10-03       Impact factor: 2.860

10.  Validity of hydration non-invasive indices during the weightcutting and official weigh-in for Olympic combat sports.

Authors:  Valentín E Fernández-Elías; Alberto Martínez-Abellán; José María López-Gullón; Ricardo Morán-Navarro; Jesús G Pallarés; Ernesto De la Cruz-Sánchez; Ricardo Mora-Rodriguez
Journal:  PLoS One       Date:  2014-04-16       Impact factor: 3.240

View more
  1 in total

1.  Validity of Urine Color Scoring Using Different Light Conditions and Scoring Techniques to Assess Urine Concentration.

Authors:  Floris Wardenaar; Scott Armistead; Kayla Boeckman; Brooke Butterick; Darya Youssefi; Daniel Thompsett; Kaila Vento
Journal:  J Athl Train       Date:  2022-02-01       Impact factor: 2.860

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.