OBJECTIVE: To evaluate feasibility of MRI in patients with non-pacemaker (PM)/ Implantable cardioverter defibrillator (ICD) metallic devices and abandoned leads.
BACKGROUND: Relative safety of MRI performed using specified protocol has been established in MR non-conditional PM/ICDs. With limited safety data, many non-PM/ICD metallic devices and abandoned leads continue to be a contraindication for MRI.
METHODS: We retrospectively analyzed consecutive patients with extra-cardiac devices, non-programmable cardiac devices, and abandoned leads, who underwent MRI (GE 1.5 Tesla, WI) at a single tertiary care center over a span of 13 years. Scan protocol was designed to maintain specific absorption rate (SAR) < 4.0 W/kg and scan time < 60 minutes.
RESULTS: The cohort comprised 127 MRI exams representing 94 patients, with 13 patients having two or more scans. The devices consisted of: 23 vagal nerve stimulators (VNS), 22 implantable loop recorders, 16 spinal stimulators, 5 peripheral nerve stimulators, 3 bladder stimulators, 2 deep brain stimulators, 1 gastric stimulator, 1 bone stimulator, 1 WATCHMAN device, 22 abandoned PM/lCD leads and 1 VNS lead. There was no immediate (peri-MRI exam) morbidity or mortality. Patients did not report any discomfort, palpitations, heating, or sensation of device migration during the exam. Local follow-up data was available in 65% (100% for thoracic imaging) with a mean of 190±475 days (median 13 days). No device malfunction reported during follow-up.
CONCLUSIONS: With appropriate precautions, MRI is feasible in patients with extracardiac devices, nonprogrammable cardiac devices, and abandoned leads.

Entities:  

Keywords:  Abandoned leads; Extra-cardiac devices; Implantable loop recorder; MRI Safety; Pacemaker

Year:  2021        PMID: 33777288      PMCID: PMC7993908          DOI: 10.4236/jbise.2021.143009

Source DB:  PubMed          Journal:  J Biomed Sci Eng        ISSN: 1937-6871


  40 in total

1.  Cardiac perforation and lead dislodgement after implantation of a MR-conditional pacing lead: a single-center experience.

Authors:  Darryl A Elmouchi; Shelly Rosema; Stacie M Vanoosterhout; Mohsin Khan; Alan T Davis; Andre J Gauri; Bohuslav Finta; Alan K Woelfel; Nagib T Chalfoun
Journal:  Pacing Clin Electrophysiol       Date:  2013-11-11       Impact factor: 1.976

2.  Low-field magnetic resonance imaging: increased safety for pacemaker patients?

Authors:  Katharina Strach; Claas Philip Naehle; Artur Mühlsteffen; Michael Hinz; Adam Bernstein; Daniel Thomas; Markus Linhart; Carsten Meyer; Sascha Bitaraf; Hans Schild; Torsten Sommer
Journal:  Europace       Date:  2010-03-31       Impact factor: 5.214

3.  Preventing accidents and injuries in the MRI suite.

Authors: 
Journal:  Sentinel Event Alert       Date:  2008-02-14

4.  Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI.

Authors:  Deborah A Langman; Ira B Goldberg; J Paul Finn; Daniel B Ennis
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

5.  NMR in cancer: XVI. FONAR image of the live human body.

Authors:  R Damadian; M Goldsmith; L Minkoff
Journal:  Physiol Chem Phys       Date:  1977

6.  FDA approves first pacemaker system safe for magnetic resonance imaging. Traditional cardiac devices have been at risk of malfunctioning or overheating with MRIs.

Authors: 
Journal:  Heart Advis       Date:  2011-04

Review 7.  Extra-cardiac stimulators: what do cardiologists need to know?

Authors:  Alexandre Guinand; Stéphane Noble; Angela Frei; Julien Renard; Martin R Tramer; Haran Burri
Journal:  Europace       Date:  2016-05-26       Impact factor: 5.214

8.  Diagnostic Value of MRI in Patients With Implanted Pacemakers and Implantable Cardioverter-Defibrillators Across a Cross Population: Does the Benefit Justify the Risk? A Proof of Concept Study.

Authors:  Huma Samar; June A Yamrozik; Ronald B Williams; Mark Doyle; Moneal Shah; Christopher A Bonnet; Robert W W Biederman
Journal:  JACC Clin Electrophysiol       Date:  2017-06-28

9.  Safety and outcomes of magnetic resonance imaging in patients with abandoned pacemaker and defibrillator leads.

Authors:  John V Higgins; Joseph J Gard; Seth H Sheldon; Raul E Espinosa; Christopher P Wood; Joel P Felmlee; Yong-Mei Cha; Samuel J Asirvatham; Connie Dalzell; Nancy Acker; Robert E Watson; Paul A Friedman
Journal:  Pacing Clin Electrophysiol       Date:  2014-05-09       Impact factor: 1.976

10.  Frequency and clinical impact of retained implantable cardioverter defibrillator lead materials in heart transplant recipients.

Authors:  Jun Kim; Jongmin Hwang; Jin Hee Choi; Hyo-In Choi; Min-Seok Kim; Sung-Ho Jung; Gi-Byoung Nam; Kee-Joon Choi; Jae Won Lee; You-Ho Kim; Jae-Joong Kim
Journal:  PLoS One       Date:  2017-05-02       Impact factor: 3.240

View more
  1 in total

1.  Magnetic resonance imaging in a patient with cardiac resynchronization therapy-defibrillator and two abandoned leads.

Authors:  Enzo Lüsebrink; Stefan Kääb; Stephanie Fichtner
Journal:  J Arrhythm       Date:  2022-06-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.